Reference record for OID 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.10



parent
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1 (temperatureSensors)
node code
10
node name
tempUpperDamageLevel
dot oid
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.10
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) sniProductMibs(2) sniExtensions(10) sniServerMgmt(2) sniCommon(2) sniServerControl(5) environment(2) temperatureSensorsTable(1) temperatureSensors(1) tempUpperDamageLevel(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) sniProductMibs(2) sniExtensions(10) sniServerMgmt(2) sniCommon(2) sniServerControl(5) environment(2) temperatureSensorsTable(1) temperatureSensors(1) tempUpperDamageLevel(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sni(231) sniProductMibs(2) sniExtensions(10) sniServerMgmt(2) sniCommon(2) sniServerControl(5) environment(2) temperatureSensorsTable(1) temperatureSensors(1) tempUpperDamageLevel(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sni(231) sniProductMibs(2) sniExtensions(10) sniServerMgmt(2) sniCommon(2) sniServerControl(5) environment(2) temperatureSensorsTable(1) temperatureSensors(1) tempUpperDamageLevel(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) sniProductMibs(2) sniExtensions(10) sniServerMgmt(2) sniCommon(2) sniServerControl(5) environment(2) temperatureSensorsTable(1) temperatureSensors(1) tempUpperDamageLevel(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) sniProductMibs(2) sniExtensions(10) sniServerMgmt(2) sniCommon(2) sniServerControl(5) environment(2) temperatureSensorsTable(1) temperatureSensors(1) tempUpperDamageLevel(10)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/sni/sniProductMibs/sniExtensions/sniServerMgmt/sniCommon/sniServerControl/environment/temperatureSensorsTable/temperatureSensors/tempUpperDamageLevel
  • /iso/identified-organization/dod/internet/private/enterprises/sni/sniProductMibs/sniExtensions/sniServerMgmt/sniCommon/sniServerControl/environment/temperatureSensorsTable/temperatureSensors/tempUpperDamageLevel
  • /iso/org/dod/internet/private/enterprise/sni/sniProductMibs/sniExtensions/sniServerMgmt/sniCommon/sniServerControl/environment/temperatureSensorsTable/temperatureSensors/tempUpperDamageLevel
  • /iso/org/dod/internet/private/enterprises/sni/sniProductMibs/sniExtensions/sniServerMgmt/sniCommon/sniServerControl/environment/temperatureSensorsTable/temperatureSensors/tempUpperDamageLevel
  • /iso/iso-identified-organization/dod/internet/private/enterprise/sni/sniProductMibs/sniExtensions/sniServerMgmt/sniCommon/sniServerControl/environment/temperatureSensorsTable/temperatureSensors/tempUpperDamageLevel
  • /iso/iso-identified-organization/dod/internet/private/enterprises/sni/sniProductMibs/sniExtensions/sniServerMgmt/sniCommon/sniServerControl/environment/temperatureSensorsTable/temperatureSensors/tempUpperDamageLevel
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/231/2/10/2/2/5/2/1/1/10

    Description by mibdepot

    Object made obsolete - no longer supported

    Parsed from file SC.mib.txt
    Company: cai
    Module: SNI-SERVER-CONTROL-MIB

    Information by oid_info

    Vendor: Computer Associates
    Module: SNI-SERVER-CONTROL-MIB (SC.mib)
    Type: TABULAR
    Access: read-only
    Syntax: INTEGER
    (
    0..127 )

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    tempUpperDamageLevel OBJECT-TYPE SYNTAX INTEGER(0..127) ACCESS read-only STATUS obsolete DESCRIPTION "Object made obsolete - no longer supported" ::= { temperatureSensors 10 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.231)

    Rothe Detlef

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.1 tempCabinetId 0 0 ID of the cabinet the temperature sensor is in (index, 0 based)
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.2 tempSensorNumber 0 0 Number of the sensor in this cabinet (index, 0 based)
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3 tempSensorStatus 0 0 Status of this temperature sensor (OK, critical or shutdown
    temperature reached...). The cold and the damage temperature status …
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.4 tempSensorPurpose 0 0 Purpose of this temperature sensor (CPU, ambient, housing...).
    Purposes disable(2) and not-available(6) are no longer used.
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.5 tempLowerWarningLevel 0 0 Object made obsolete - no longer supported
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.6 tempUpperWarningLevel 0 0 System sends a temperature warning when temperature rises ABOVE
    this level (degrees Celsius)
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.7 tempLowerCriticalLevel 0 0 Object made obsolete - no longer supported
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.8 tempUpperCriticalLevel 0 0 System becomes critical when temperature rises ABOVE this level (degrees Celsius).
    A system shutdown is performed if object temp…
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.9 tempLowerDamageLevel 0 0 Object made obsolete - no longer supported
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.11 tempCurrentValue 0 0 Current temperature value (degrees Celsius; -1: unknown temperature,
    problem with sensor, see tempSensorStatus)
    1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.12 tempCriticalReaction 0 0 Reaction when a temperature gets critical (shutdown and power-off, continue...).
    The value unknown(1) cannot be set, a SET will …