Vendor: Fujitsu Siemens Computers
Module: XLDV20-MIB
[Automatically extracted from oidview.com]
xldv20AtmLoopTest OBJECT IDENTIFIER ::= { xldv20TlmOam 3 }
xldv20AtmLoopTest OBJECT IDENTIFIER ::= { xldv20TlmOam 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.1 | xldv20AltIfIndex | 1 | 1 | The TLM interface where OAM cells are inserted. It can be the 'IfIndex' of a PPTP at a LU or SU. |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.2 | xldv20AltVpi | 1 | 1 | Identifies the VPI which shall be tested. It is VPINni when test in LE direction or it is VPIUni when test in NT direction. |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.3 | xldv20AltLoopLocId | 1 | 1 | Test cell loopback location. It is an identifier known by the crafts person identifying a ATM node in the ATM network. For EndTo… |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.4 | xldv20AltControlReq | 1 | 1 | The received command to start an OAM cell loopback test (loopTestRequest). Reject reasons are faulty parameters from the agent (re… |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.5 | xldv20AltControlStatus | 1 | 1 | The status of the command handling. |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.6 | xldv20AltControlTimer | 1 | 1 | The maximum duration of loop- back test. It is required by the SNMP manager to detect the end of loopback test in case of the res… |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.7 | xldv20AltOamLevel | 1 | 1 | The OAM level for loop test on VP/VC level. Valid: f4 (for VP ) f5 (for VC). |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.8 | xldv20AltLoopTestType | 1 | 1 | The type of loop test . For EndToEnd loop test loop location ID is FF..FF. |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.9 | xldv20AltVci | 1 | 1 | Insertion point for OAM cells for F5 level |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.10 | xldv20AltControlReqResult | 1 | 1 | The result of the last user command. |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.11 | xldv20AltFlowDirection | 1 | 1 | Labels the flow direction of loop back cells. 'inwards' meanxing towards cellbus. 'outwards' meaning towards UTOPIA interface . |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.3.12 | xldv20AltControlTimeStamp | 1 | 1 | The time stamp of the last command (end of command). |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.231.7.1.2.1.1.4.5.1 | xldv20LoopBackPointTable | 1 | 3 | The loop back point table |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.2 | xldv20PhyLoopTest | 6 | 12 | None |
1.3.6.1.4.1.231.7.1.2.1.1.4.5.4 | xldv20MultipleLoopbackResultTable | 1 | 3 | The Multiple Loopback Result table. Used for the multiple loopback functionality to collect the IDs of connecting points which loo… |