The role of endpoint.
'analyseWithBackwardReporting' (sink) means extracting
forward monitoring (FM) OAM cells, sending back
backward reporting OAM cells and no data collection
for current and history table.
'analyseWithoutBackwardReporting' (sink) means extracting
FM cells without any other OAM handling
and also collecting data.
'generateWithCollect' (source) means inserting FM cells,
extracting backward reporting cells if they arrive
and collect data for current and history table.
'generateWithoutCollect' (source) means inserting FM cells
but without collecting data.
The CMU, the Ethernet part of the Twin NT s capable of
operating as inserting or extracting point.
Parsed from file xldv20pm.mib.txt
Company: None
Module: XLDV20PM-MIB
The role of endpoint.
'analyseWithBackwardReporting' (sink) means extracting
forward monitoring (FM) OAM cells, sending back
backward reporting OAM cells and no data collection
for current and history table.
'analyseWithoutBackwardReporting' (sink) means extracting
FM cells without any other OAM handling
and also collecting data.
'generateWithCollect' (source) means inserting FM cells,
extracting backward reporting cells if they arrive
and collect data for current and history table.
'generateWithoutCollect' (source) means inserting FM cells
but without collecting data.
The CMU, the Ethernet part of the Twin NT s capable of
operating as inserting or extracting point.
Parsed from file XLDV20PM-MIB.mib
Module: XLDV20PM-MIB
Vendor: Fujitsu Siemens Computers
Module: XLDV20PM-MIB
[Automatically extracted from oidview.com]
xldv20pmAcoRole OBJECT-TYPE SYNTAX Xldv20pmRoleType ACCESS read-write STATUS mandatory DESCRIPTION " The role of endpoint. 'analyseWithBackwardReporting' (sink) means extracting forward monitoring (FM) OAM cells, sending back backward reporting OAM cells and no data collection for current and history table. 'analyseWithoutBackwardReporting' (sink) means extracting FM cells without any other OAM handling and also collecting data. 'generateWithCollect' (source) means inserting FM cells, extracting backward reporting cells if they arrive and collect data for current and history table. 'generateWithoutCollect' (source) means inserting FM cells but without collecting data. The CMU, the Ethernet part of the Twin NT s capable of operating as inserting or extracting point. " ::= { xldv20pmAtmControl 12 }
xldv20pmAcoRole OBJECT-TYPE SYNTAX Xldv20pmRoleType ACCESS read-write STATUS mandatory DESCRIPTION " The role of endpoint. 'analyseWithBackwardReporting' (sink) means extracting forward monitoring (FM) OAM cells, sending back backward reporting OAM cells and no data collection for current and history table. 'analyseWithoutBackwardReporting' (sink) means extracting FM cells without any other OAM handling and also collecting data. 'generateWithCollect' (source) means inserting FM cells, extracting backward reporting cells if they arrive and collect data for current and history table. 'generateWithoutCollect' (source) means inserting FM cells but without collecting data. The CMU, the Ethernet part of the Twin NT s capable of operating as inserting or extracting point. " ::= { xldv20pmAtmControl 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.12.0 | xldv20pmAcoRole | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.1 | xldv20pmAcoIndex | 1 | 1 | This attribute provides the index of the AtmPm object for which PM parameters shall be configured . |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.2 | xldv20pmAcoNrHistEntriesSize | 1 | 1 | This attribute is used to set the number of 15 minutes history entries which should be stored for history collection. The set Hist… |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.3 | xldv20pmAcoIntervalType | 1 | 1 | This attribute identifies whether a 15 minutes interval or a day interval is selected in case of a resetIndividCurrent command. |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.4 | xldv20pmAcoControlReq | 1 | 1 | This attribute identifies a control command given by the SNMP agent. A reset for any individual PM object is possible via command … |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.5 | xldv20pmAcoControlStatus | 1 | 1 | The status of a control request. |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.6 | xldv20pmAcoRemainingHistoryEntriesSize | 1 | 1 | This attribute indicates the number of remaining history entries which are available for the 15 minutes history collection within… |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.7 | xldv20pmAcoFlowType | 1 | 1 | This attribute identifies the flow type : F4 (VP) or F5 (VC) segment or endToEnd flow. |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.8 | xldv20pmAcoFlowDirection | 1 | 1 | The flow direction of OAM cells. 'inwards' means flow direction from outside (external interface) to cross connection. 'outwards' … |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.9 | xldv20pmAcoConnectionIndex | 1 | 1 | This attribute identifies the index of a Vpl or Vcl cross connection. |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.10 | xldv20pmAcoConnectionIndexType | 1 | 1 | This attribute identifies the type of connection index and the termination point. It is in case of vplUni/vplNni : index of Vpl C… |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.13 | xldv20pmAcoEndpointType | 1 | 1 | Identifies the type of endpoint. |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.14 | xldv20pmAcoControlReqResult | 1 | 1 | The result of the last user command. |
1.3.6.1.4.1.231.7.1.2.1.1.5.1.2.15 | xldv20pmAcoControlTimeStamp | 1 | 1 | The time stamp of the last command (end of command). |