This value specifies the status of the hot plug slot.
The hot plug slot status is set as follows:
noError(1)
The slot is operating normally.
generalError(2)
A general error occurred.
wrongRevision(3)
The revision of the replacement adapter was different from
the original adapter.
wrongBoard(4)
The model of the replacement adapter was different from the
original adapter.
cannotConfig(5)
The adapter could not be configured.
powerFault(6)
A power fault occurred for the slot.
unexpectedPowerLoss(7)
Power was unexpectedly lost from the slot.
wrongSpeed(8)
The adapter cannot be run at the current bus speed.
functionlFailure(9)
The adapter is not functioning correctly. This may
be caused by a cabling problem.
Parsed from file CPQSINFO1.MIB.txt
Company: None
Module: CPQSINFO-MIB
This value specifies the status of the hot plug slot.
The hot plug slot status is set as follows:
noError(1)
The slot is operating normally.
generalError(2)
A general error occurred.
wrongRevision(3)
The revision of the replacement adapter was different from
the original adapter.
wrongBoard(4)
The model of the replacement adapter was different from the
original adapter.
cannotConfig(5)
The adapter could not be configured.
powerFault(6)
A power fault occurred for the slot.
unexpectedPowerLoss(7)
Power was unexpectedly lost from the slot.
wrongSpeed(8)
The adapter cannot be run at the current bus speed.
functionlFailure(9)
The adapter is not functioning correctly. This may
be caused by a cabling problem.
Parsed from file CPQSINFO-MIB.mib
Module: CPQSINFO-MIB
cpqSiHotPlugSlotErrorStatus OBJECT-TYPE SYNTAX INTEGER { noError(1), generalError(2), wrongRevision(3), wrongBoard(4), cannotConfig(5), powerFault(6), unexpectedPowerLoss(7), wrongSpeed(8), functionalFailure(9) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the status of the hot plug slot. The hot plug slot status is set as follows: noError(1) The slot is operating normally. generalError(2) A general error occurred. wrongRevision(3) The revision of the replacement adapter was different from the original adapter. wrongBoard(4) The model of the replacement adapter was different from the original adapter. cannotConfig(5) The adapter could not be configured. powerFault(6) A power fault occurred for the slot. unexpectedPowerLoss(7) Power was unexpectedly lost from the slot. wrongSpeed(8) The adapter cannot be run at the current bus speed. functionlFailure(9) The adapter is not functioning correctly. This may be caused by a cabling problem." ::= { cpqSiHotPlugSlotEntry 6 }
Vendor: Compaq
Module: CPQSINFO-MIB
[Automatically extracted from oidview.com]
cpqSiHotPlugSlotErrorStatus OBJECT-TYPE SYNTAX INTEGER { noError(1), generalError(2), wrongRevision(3), wrongBoard(4), cannotConfig(5), powerFault(6), unexpectedPowerLoss(7), wrongSpeed(8), functionalFailure(9) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the status of the hot plug slot. The hot plug slot status is set as follows: noError(1) The slot is operating normally. generalError(2) A general error occurred. wrongRevision(3) The revision of the replacement adapter was different from the original adapter. wrongBoard(4) The model of the replacement adapter was different from the original adapter. cannotConfig(5) The adapter could not be configured. powerFault(6) A power fault occurred for the slot. unexpectedPowerLoss(7) Power was unexpectedly lost from the slot. wrongSpeed(8) The adapter cannot be run at the current bus speed. functionlFailure(9) The adapter is not functioning correctly. This may be caused by a cabling problem." ::= { cpqSiHotPlugSlotEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.2.2.9.4.1.1 | cpqSiHotPlugSlotChassis | 0 | 0 | The Chassis where this hot plug slot resides. |
1.3.6.1.4.1.232.2.2.9.4.1.2 | cpqSiHotPlugSlotIndex | 0 | 0 | The slot within the chassis for this hot plug slot. |
1.3.6.1.4.1.232.2.2.9.4.1.3 | cpqSiHotPlugSlotBoardPresent | 0 | 0 | This value indicates whether a board is present(2) in or absent(3) from the slot. A value of other(1) indicates the information … |
1.3.6.1.4.1.232.2.2.9.4.1.4 | cpqSiHotPlugSlotPowerState | 0 | 0 | This value is set to powerOn(2) when power is being supplied to the slot and powerOff(3) when power is not being supplied. A valu… |
1.3.6.1.4.1.232.2.2.9.4.1.5 | cpqSiHotPlugSlotBoardCondition | 0 | 0 | This value specifies the condition of the hot plug slot. The hot plug condition is set as follows: other(1) When the condition cou… |
1.3.6.1.4.1.232.2.2.9.4.1.7 | cpqSiHotPlugSlotHwLocation | 0 | 0 | A text description of the hardware location, on complex multi SBB hardware only, for the hot plug slot. A NULL string indicates t… |