Compaq Array Controller Entry.
Parsed from file CPQIDA2.MIB.txt
Company: None
Module: CPQIDA-MIB
Array Controller Entry.
Parsed from file CPQIDA-MIB.mib
Module: CPQIDA-MIB
cpqDaCntlrEntry OBJECT-TYPE SYNTAX CpqDaCntlrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Array Controller Entry." INDEX { cpqDaCntlrIndex } ::= { cpqDaCntlrTable 1 }
Vendor: Compaq
Module: CPQIDA-MIB
[Automatically extracted from oidview.com]
cpqDaCntlrEntry OBJECT-TYPE SYNTAX CpqDaCntlrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Array Controller Entry." INDEX { cpqDaCntlrIndex } ::= { cpqDaCntlrTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.3.2.2.1.1.1 | cpqDaCntlrIndex | 0 | 0 | Array Controller Index. This value is a logical number whose meaning is OS dependent. Each physical controller has one unique con… |
1.3.6.1.4.1.232.3.2.2.1.1.2 | cpqDaCntlrModel | 0 | 0 | Compaq Array Controller Model. The type of controller card. The valid types are: Other (1) You may need to upgrade your driver s… |
1.3.6.1.4.1.232.3.2.2.1.1.3 | cpqDaCntlrFWRev | 0 | 0 | Array Controller Firmware Revision. The firmware revision of the drive array controller. This value can be used to help identify … |
1.3.6.1.4.1.232.3.2.2.1.1.4 | cpqDaCntlrStndIntr | 0 | 0 | The status of the Standard Interface. The Standard Interface is how DOS communicates with a drive. The following values are valid… |
1.3.6.1.4.1.232.3.2.2.1.1.5 | cpqDaCntlrSlot | 0 | 0 | Array Controller Slot. This identifies the physical slot where the array controller resides in the system. For example, if this … |
1.3.6.1.4.1.232.3.2.2.1.1.6 | cpqDaCntlrCondition | 0 | 0 | The condition of the device. This value represents the overall condition of this controller, and any associated logical drives,… |
1.3.6.1.4.1.232.3.2.2.1.1.7 | cpqDaCntlrProductRev | 0 | 0 | Array Controller Product Revision. The Product Revision of the drive array controller. This value can be used to further identif… |
1.3.6.1.4.1.232.3.2.2.1.1.8 | cpqDaCntlrPartnerSlot | 0 | 0 | Array Controller Partner Slot. For duplexed array controllers, this is the slot number of the partner controller. For non-duplex… |
1.3.6.1.4.1.232.3.2.2.1.1.9 | cpqDaCntlrCurrentRole | 0 | 0 | Array Controller Current Role. For duplexed array controllers, this is the controllers current role. The following values are va… |
1.3.6.1.4.1.232.3.2.2.1.1.10 | cpqDaCntlrBoardStatus | 0 | 0 | Array Controller Board Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize th… |
1.3.6.1.4.1.232.3.2.2.1.1.11 | cpqDaCntlrPartnerBoardStatus | 0 | 0 | Array Controller Partner Board Status. The following values are valid: other (1) Indicates that the instrument agent does not reco… |
1.3.6.1.4.1.232.3.2.2.1.1.12 | cpqDaCntlrBoardCondition | 0 | 0 | The condition of the device. This value represents the condition of the controller and any associated array accelerators. |
1.3.6.1.4.1.232.3.2.2.1.1.13 | cpqDaCntlrPartnerBoardCondition | 0 | 0 | The condition of the device. This value represents the condition of the controller and any associated array accelerators. |
1.3.6.1.4.1.232.3.2.2.1.1.14 | cpqDaCntlrDriveOwnership | 0 | 0 | Array Controller Drive Ownership. For duplexed controllers, indicates to which controller slot the shared devices are associated.… |
1.3.6.1.4.1.232.3.2.2.1.1.15 | cpqDaCntlrSerialNumber | 0 | 0 | Array Controller Serial Number. The serial number of the array controller. This field will be a null (size 0) string if the cont… |
1.3.6.1.4.1.232.3.2.2.1.1.16 | cpqDaCntlrRedundancyType | 0 | 0 | Array Controller Redundancy Type. The following values are valid: other (1) Indicates that the instrument agent does not recognize… |
1.3.6.1.4.1.232.3.2.2.1.1.17 | cpqDaCntlrRedundancyError | 0 | 0 | Array Controller Redundancy Error. The following values are valid: other (1) Indicates that the instrument agent does not recogniz… |
1.3.6.1.4.1.232.3.2.2.1.1.18 | cpqDaCntlrAccessModuleStatus | 0 | 0 | Array Controller RAID ADG Enabler Module Status. The following values are valid: other (1) Indicates that the agent does not recog… |
1.3.6.1.4.1.232.3.2.2.1.1.19 | cpqDaCntlrDaughterBoardType | 0 | 0 | Compaq Array Controller Daughter Board Type. The following values are valid: other (1) Indicates that the agent does not recognize… |
1.3.6.1.4.1.232.3.2.2.1.1.20 | cpqDaCntlrHwLocation | 0 | 0 | A text description of the hardware location of the controller. A NULL string indicates that the hardware location could not be de… |
1.3.6.1.4.1.232.3.2.2.1.1.21 | cpqDaCntlrNumberOfBuses | 0 | 0 | Array Controller Number of Buses. This value is the number of SCSI buses on the controller. |
1.3.6.1.4.1.232.3.2.2.1.1.22 | cpqDaCntlrBlinkTime | 0 | 0 | Controller Physical Drive Blink Time Count. The controller blink time variable allows the drive tray LEDs of all physical drives … |
1.3.6.1.4.1.232.3.2.2.1.1.23 | cpqDaCntlrRebuildPriority | 0 | 0 | Array Controller Rebuild Priority. This is the controller's rebuild priority. The following values are valid: other (1) Indicates … |
1.3.6.1.4.1.232.3.2.2.1.1.24 | cpqDaCntlrExpandPriority | 0 | 0 | Array Controller Expand Priority. This is the controller's expand priority. The following values are valid: other (1) Indicates th… |
1.3.6.1.4.1.232.3.2.2.1.1.25 | cpqDaCntlrNumberOfInternalPorts | 0 | 0 | Array Controller Number of Internal Ports. This value is the number of internal SAS connectors on the controller. |
1.3.6.1.4.1.232.3.2.2.1.1.26 | cpqDaCntlrNumberOfExternalPorts | 0 | 0 | Array Controller Number of External Ports. This value is the number of external SAS connectoros on the controller. |
1.3.6.1.4.1.232.3.2.2.1.1.27 | cpqDaCntlrDriveWriteCacheState | 0 | 0 | Array Controller Drive Write Cache State. This is the controller's drive write cache setting. The following values are valid: oth… |
1.3.6.1.4.1.232.3.2.2.1.1.28 | cpqDaCntlrPartnerSerialNumber | 0 | 0 | Array Controller Partner Serial Number. The serial number of the partner array controller. This field will be a null (size 0) st… |