Drive Array Logical Drive Entry.
A logical drive entry.
Parsed from file CPQIDA2.MIB.txt
Company: None
Module: CPQIDA-MIB
Drive Array Logical Drive Entry.
A logical drive entry.
Parsed from file CPQIDA-MIB.mib
Module: CPQIDA-MIB
cpqDaLogDrvEntry OBJECT-TYPE SYNTAX CpqDaLogDrvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Drive Array Logical Drive Entry. A logical drive entry." INDEX { cpqDaLogDrvCntlrIndex, cpqDaLogDrvIndex } ::= { cpqDaLogDrvTable 1 }
Vendor: Compaq
Module: CPQIDA-MIB
[Automatically extracted from oidview.com]
cpqDaLogDrvEntry OBJECT-TYPE SYNTAX CpqDaLogDrvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Drive Array Logical Drive Entry. A logical drive entry." INDEX { cpqDaLogDrvCntlrIndex, cpqDaLogDrvIndex } ::= { cpqDaLogDrvTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.3.2.3.1.1.1 | cpqDaLogDrvCntlrIndex | 0 | 0 | Drive Array Logical Drive Controller Index. This maps the logical drives into their respective controllers. Controller index 'i' … |
1.3.6.1.4.1.232.3.2.3.1.1.2 | cpqDaLogDrvIndex | 0 | 0 | Drive Array Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are on the s… |
1.3.6.1.4.1.232.3.2.3.1.1.3 | cpqDaLogDrvFaultTol | 0 | 0 | Logical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. To change the fault tolerance mode, run … |
1.3.6.1.4.1.232.3.2.3.1.1.4 | cpqDaLogDrvStatus | 0 | 0 | Logical Drive Status. The logical drive can be in one of the following states: Ok (2) Indicates that the logical drive is in norma… |
1.3.6.1.4.1.232.3.2.3.1.1.5 | cpqDaLogDrvAutoRel | 0 | 0 | Array Controller Logical Drive Auto-Reliability Delay. This value indicates how many seconds the logical drive will wait with no … |
1.3.6.1.4.1.232.3.2.3.1.1.6 | cpqDaLogDrvRebuildBlks | 0 | 0 | Logical Drive Rebuild Blocks Remaining. After a failed physical drive has been replaced, the physical drive must have its data re… |
1.3.6.1.4.1.232.3.2.3.1.1.7 | cpqDaLogDrvHasAccel | 0 | 0 | Logical Drive Has Array Accelerator Board. This indicates whether the logical drive has an Array Accelerator board configured and… |
1.3.6.1.4.1.232.3.2.3.1.1.8 | cpqDaLogDrvAvailSpares | 0 | 0 | Drive Array Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that ar… |
1.3.6.1.4.1.232.3.2.3.1.1.9 | cpqDaLogDrvSize | 0 | 0 | Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20… |
1.3.6.1.4.1.232.3.2.3.1.1.10 | cpqDaLogDrvPhyDrvIDs | 0 | 0 | Drive Array Logical Drive Physical Drive IDs. This lists the physical drive IDs which are associated with this logical drive. The… |
1.3.6.1.4.1.232.3.2.3.1.1.11 | cpqDaLogDrvCondition | 0 | 0 | The Logical Drive condition. This value represents the overall condition of this logical drive and any associated physical drives. |
1.3.6.1.4.1.232.3.2.3.1.1.12 | cpqDaLogDrvPercentRebuild | 0 | 0 | Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. T… |
1.3.6.1.4.1.232.3.2.3.1.1.13 | cpqDaLogDrvStripeSize | 0 | 0 | Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes. |
1.3.6.1.4.1.232.3.2.3.1.1.14 | cpqDaLogDrvOsName | 0 | 0 | Logical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the agent does not… |
1.3.6.1.4.1.232.3.2.3.1.1.15 | cpqDaLogDrvBlinkTime | 0 | 0 | Logical Drive Physical Drive Blink Time Count. The logical drive blink time variable allows the drive tray LEDs of all physical d… |
1.3.6.1.4.1.232.3.2.3.1.1.16 | cpqDaLogDrvSpareReplaceMap | 0 | 0 | Logical Drive Spare To Replacement Drive Map. This data structure contains the spare to physical drive replacement map. The form… |
1.3.6.1.4.1.232.3.2.3.1.1.17 | cpqDaLogDrvRebuildingPhyDrv | 0 | 0 | Logical Drive Physical Drive Rebuilding Index. This is the physical drive index of the physical drive that is currently rebuildin… |
1.3.6.1.4.1.232.3.2.3.1.1.18 | cpqDaLogDrvMultipathAccess | 0 | 0 | Logical Drive Multi-path Access. This indicates whether all the physical disks including spares of this logical drive have been c… |
1.3.6.1.4.1.232.3.2.3.1.1.19 | cpqDaLogDrvNmbrOfParityGroups | 0 | 0 | Logical Drive Number Of Parity Groups. Indicates the number of parity groups (i.e. RAID 4/5/6 subvolumes), that are being striped… |