Drive Array Spare Entry.
An entry in the spare table.
Parsed from file CPQIDA2.MIB.txt
Company: None
Module: CPQIDA-MIB
Drive Array Spare Entry.
An entry in the spare table.
Parsed from file CPQIDA-MIB.mib
Module: CPQIDA-MIB
cpqDaSpareEntry OBJECT-TYPE SYNTAX CpqDaSpareEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Drive Array Spare Entry. An entry in the spare table." INDEX { cpqDaSpareCntlrIndex, cpqDaSparePhyDrvIndex } ::= { cpqDaSpareTable 1 }
Vendor: Compaq
Module: CPQIDA-MIB
[Automatically extracted from oidview.com]
cpqDaSpareEntry OBJECT-TYPE SYNTAX CpqDaSpareEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Drive Array Spare Entry. An entry in the spare table." INDEX { cpqDaSpareCntlrIndex, cpqDaSparePhyDrvIndex } ::= { cpqDaSpareTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.3.2.4.1.1.1 | cpqDaSpareCntlrIndex | 0 | 0 | Drive Array Spare Controller Index. This index maps the spare drive back to the controller to which it is attached. The value of… |
1.3.6.1.4.1.232.3.2.4.1.1.2 | cpqDaSparePhyDrvIndex | 0 | 0 | Drive Array Spare Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is… |
1.3.6.1.4.1.232.3.2.4.1.1.3 | cpqDaSpareStatus | 0 | 0 | Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Failed (3) The… |
1.3.6.1.4.1.232.3.2.4.1.1.4 | cpqDaSpareReplacedDrv | 0 | 0 | Spare Replaced Drive. If the spare status is active(6) or building(5), then this has the physical drive number of the replaced dr… |
1.3.6.1.4.1.232.3.2.4.1.1.5 | cpqDaSpareRebuildBlks | 0 | 0 | Drive Array Spare Number Of Rebuild Blocks Left. If the spare status is building(5), then this is the number of blocks left to re… |
1.3.6.1.4.1.232.3.2.4.1.1.6 | cpqDaSpareCondition | 0 | 0 | The Spare Drive condition. This value represents the overall condition of this spare drive and any associated physical drives. |
1.3.6.1.4.1.232.3.2.4.1.1.7 | cpqDaSpareBusNumber | 0 | 0 | Spare Drive SCSI Bus Number. The bus number indicates to which SCSI bus this spare drive is attached. The first instance is one … |
1.3.6.1.4.1.232.3.2.4.1.1.8 | cpqDaSpareBay | 0 | 0 | Spare Drive Bay Location. This value matches the bay location where the physical drive has been installed. For a SCSI drive, thi… |
1.3.6.1.4.1.232.3.2.4.1.1.9 | cpqDaSpareReplacedDrvBusNumber | 0 | 0 | Spare Replaced Drive Bus Number. If the spare status is active(6) or building(5), then this has the physical drive bus number of … |
1.3.6.1.4.1.232.3.2.4.1.1.10 | cpqDaSpareReplacedDrvBay | 0 | 0 | Spare Replaced Drive Bay. If the spare status is active(6) or building(5), then this has the physical drive bay number of the rep… |
1.3.6.1.4.1.232.3.2.4.1.1.11 | cpqDaSparePercentRebuild | 0 | 0 | Drive Array Spare Percent Rebuild. If the spare status is building(5), then this is percent complete of of the rebuild. The data c… |
1.3.6.1.4.1.232.3.2.4.1.1.12 | cpqDaSpareLocationString | 0 | 0 | Spare Drive Location String. This string describes the location of the drive in relation to the controller. If the location stri… |