Reference record for OID 1.3.6.1.4.1.2468.1.2.1.1.2.2
- parent
- 1.3.6.1.4.1.2468.1.2.1.1.2 (upsBatteryGroup)
- node code
- 2
- node name
- upsBatteryGroupSecondsOnBattery
- dot oid
- 1.3.6.1.4.1.2468.1.2.1.1.2.2
- type
- OBJECT-TYPE
- asn1 oid
-
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsBatteryGroup(2) upsBatteryGroupSecondsOnBattery(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsBatteryGroup(2) upsBatteryGroupSecondsOnBattery(2)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsBatteryGroup(2) upsBatteryGroupSecondsOnBattery(2)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsBatteryGroup(2) upsBatteryGroupSecondsOnBattery(2)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsBatteryGroup(2) upsBatteryGroupSecondsOnBattery(2)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsBatteryGroup(2) upsBatteryGroupSecondsOnBattery(2)}
- iri oid
-
- /iso/identified-organization/dod/internet/private/enterprise/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsBatteryGroup/upsBatteryGroupSecondsOnBattery
- /iso/identified-organization/dod/internet/private/enterprises/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsBatteryGroup/upsBatteryGroupSecondsOnBattery
- /iso/org/dod/internet/private/enterprise/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsBatteryGroup/upsBatteryGroupSecondsOnBattery
- /iso/org/dod/internet/private/enterprises/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsBatteryGroup/upsBatteryGroupSecondsOnBattery
- /iso/iso-identified-organization/dod/internet/private/enterprise/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsBatteryGroup/upsBatteryGroupSecondsOnBattery
- /iso/iso-identified-organization/dod/internet/private/enterprises/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsBatteryGroup/upsBatteryGroupSecondsOnBattery
- iri by oid_info
- /ISO/Identified-Organization/6/1/4/1/2468/1/2/1/1/2/2
Description by circitor
If the unit is on battery power, the elapsed time
since the UPS last switched to battery power, or the
time since the network management subsystem was last
restarted, whichever is less. 0 shall be returned
if the unit is not on battery power.
Parsed from file USHA-MIB.mib
Module: USHA-MIB
Information by oid_info
Vendor: Ingrasys
Module: USHA-MIB
[Automatically extracted from oidview.com]
Information by circitor
upsBatteryGroupSecondsOnBattery OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the unit is on battery power, the elapsed time
since the UPS last switched to battery power, or the
time since the network management subsystem was last
restarted, whichever is less. 0 shall be returned
if the unit is not on battery power."
::= { upsBatteryGroup 2 }
First Registration Authority (recovered by parent 1.3.6.1.4.1.2468)
Hsiao Ben
Brothers (6)
OID | Name | Sub children | Sub Nodes Total | Description |
1.3.6.1.4.1.2468.1.2.1.1.2.1 |
upsBatteryGroupStatus |
0 |
0 |
The indication of the status in the UPS system's batteries. |
1.3.6.1.4.1.2468.1.2.1.1.2.3 |
upsBatteryGroupEstimatedMinutesRemaining |
0 |
0 |
An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off… |
1.3.6.1.4.1.2468.1.2.1.1.2.4 |
upsBatteryGroupEstimatedChargeRemaining |
0 |
0 |
An estimate of the battery charge remaining expressed as a percent of full charge. |
1.3.6.1.4.1.2468.1.2.1.1.2.5 |
upsBatteryGroupVoltage |
0 |
0 |
The magnitude of the present battery voltage in 0.1 Volt DC. |
1.3.6.1.4.1.2468.1.2.1.1.2.6 |
upsBatteryGroupMandatory |
0 |
0 |
The present battery mandatory. |
1.3.6.1.4.1.2468.1.2.1.1.2.7 |
upsBatteryGroupTemperature |
0 |
0 |
The ambient temperature at or near the UPS Battery casing. |