Reference record for OID 1.3.6.1.4.1.2468.1.2.1.1.6.2



parent
1.3.6.1.4.1.2468.1.2.1.1.6 (upsTestGroup)
node code
2
node name
upsBatteryTest
dot oid
1.3.6.1.4.1.2468.1.2.1.1.6.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsTestGroup(6) upsBatteryTest(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsTestGroup(6) upsBatteryTest(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsTestGroup(6) upsBatteryTest(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsTestGroup(6) upsBatteryTest(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsTestGroup(6) upsBatteryTest(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468) product(1) upsAgent(2) ushap(1) upsObjectGroup(1) upsTestGroup(6) upsBatteryTest(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsTestGroup/upsBatteryTest
  • /iso/identified-organization/dod/internet/private/enterprises/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsTestGroup/upsBatteryTest
  • /iso/org/dod/internet/private/enterprise/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsTestGroup/upsBatteryTest
  • /iso/org/dod/internet/private/enterprises/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsTestGroup/upsBatteryTest
  • /iso/iso-identified-organization/dod/internet/private/enterprise/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsTestGroup/upsBatteryTest
  • /iso/iso-identified-organization/dod/internet/private/enterprises/ingrasys/product/upsAgent/ushap/upsObjectGroup/upsTestGroup/upsBatteryTest
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2468/1/2/1/1/6/2

    Description by circitor

    This object specify the battery test type and initiate
    battery test. If battTestWithTime selected, the test
    time is refer to upsTestBatteryTestTime.

    Parsed from file USHA-MIB.mib
    Module: USHA-MIB

    Information by oid_info

    Vendor: Ingrasys
    Module: USHA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsBatteryTest OBJECT-TYPE SYNTAX INTEGER { none(1), battTest10sec(2), battTestUntilLow(3), battTestWithTime(4), battTestCancelTest(5), battTestClearInfo(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specify the battery test type and initiate battery test. If battTestWithTime selected, the test time is refer to upsTestBatteryTestTime." ::= { upsTestGroup 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2468)

    Hsiao Ben

    Brothers (5)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2468.1.2.1.1.6.1 upsTestBatteryTestSettingTime 0 0 The object specify the test time for battery test.
    1.3.6.1.4.1.2468.1.2.1.1.6.3 upsTestBatteryTestResult 0 0 The results of the current or last UPS diagnostics
    test performed. The values for donePassed(1),
    doneWarning(2), and doneError(3…
    1.3.6.1.4.1.2468.1.2.1.1.6.4 upsTestBatteryTestStartTime 0 0 The value of the time the test in progress was initiated,
    or, if no test is in progress, the time the previous test
    was initiated…
    1.3.6.1.4.1.2468.1.2.1.1.6.5 upsTestBatteryTestElapsedTime 0 0 The amount of time, in TimeTicks, since the test in
    progress was initiated, or, if no test is in progress,
    the previous test took…
    1.3.6.1.4.1.2468.1.2.1.1.6.6 upsBatteryTestScheduleTable 1 7 Table which describes the schedule for automatically battery
    test.