The name of OutputTray in which a user can set up.
In MailBin, use it in order to indicate a user's
name, etc. which each Tray set up.
The recommendation default is the same as mltSysOutputTrayDefaultName.
Set of the character string up to 15 characters shall be possible,
and neither retrenchment of the number of characters
which can be written in, nor implementation of RO
shall be accepted.
However, the implementation of RO is accepted only
to the thing without MailBin as OutputOption.
Moreover, being reflected in the display screen of
a printer driver is desirable.
Since this item is the value used when a user does
a remote management, it is not necessary to link it
with a setup of a printer engine. SNMP agent holds value,
and should just provide the convenience to the user who
remote accesses.
If device cannot support this function, this object
should be '-' as ReadOnly.
Parsed from file mc2350-mib-ver02.mib.txt
Company: None
Module: MC2350-MIB
The name of OutputTray in which a user can set up.
In MailBin, use it in order to indicate a user's
name, etc. which each Tray set up.
The recommendation default is the same as mltSysOutputTrayDefaultName.
Set of the character string up to 15 characters shall be possible,
and neither retrenchment of the number of characters
which can be written in, nor implementation of RO
shall be accepted.
However, the implementation of RO is accepted only
to the thing without MailBin as OutputOption.
Moreover, being reflected in the display screen of
a printer driver is desirable.
Since this item is the value used when a user does
a remote management, it is not necessary to link it
with a setup of a printer engine. SNMP agent holds value,
and should just provide the convenience to the user who
remote accesses.
If device cannot support this function, this object
should be '-' as ReadOnly.
Parsed from file MC2350-MIB.mib
Module: MC2350-MIB
mltSysOutputTrayNickName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of OutputTray in which a user can set up. In MailBin, use it in order to indicate a user's name, etc. which each Tray set up. The recommendation default is the same as mltSysOutputTrayDefaultName. Set of the character string up to 15 characters shall be possible, and neither retrenchment of the number of characters which can be written in, nor implementation of RO shall be accepted. However, the implementation of RO is accepted only to the thing without MailBin as OutputOption. Moreover, being reflected in the display screen of a printer driver is desirable. Since this item is the value used when a user does a remote management, it is not necessary to link it with a setup of a printer engine. SNMP agent holds value, and should just provide the convenience to the user who remote accesses. If device cannot support this function, this object should be '-' as ReadOnly. " ::= { mltSysOutputTrayEntry 4 }
Vendor: Minolta Co., Ltd.
Module: MC2350-MIB
[Automatically extracted from oidview.com]
mltSysOutputTrayNickName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of OutputTray in which a user can set up. In MailBin, use it in order to indicate a user's name, etc. which each Tray set up. The recommendation default is the same as mltSysOutputTrayDefaultName. Set of the character string up to 15 characters shall be possible, and neither retrenchment of the number of characters which can be written in, nor implementation of RO shall be accepted. However, the implementation of RO is accepted only to the thing without MailBin as OutputOption. Moreover, being reflected in the display screen of a printer driver is desirable. Since this item is the value used when a user does a remote management, it is not necessary to link it with a setup of a printer engine. SNMP agent holds value, and should just provide the convenience to the user who remote accesses. If device cannot support this function, this object should be '-' as ReadOnly. " ::= { mltSysOutputTrayEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2590.1.1.1.5.6.3.1.1 | mltSysOutputTrayIndex | 0 | 0 | Index for showing OutputTray in a system. Index depends on the implementation of a model, and shall be taken the amount which is … |
1.3.6.1.4.1.2590.1.1.1.5.6.3.1.2 | mltSysOutputTrayRefIndex | 0 | 0 | Value of prtOutputIndex of the tray which mltSysOutputTrayIndex shows. |
1.3.6.1.4.1.2590.1.1.1.5.6.3.1.3 | mltSysOutputTrayDefaultName | 0 | 0 | The name of OutputTray. Unify with the notation of a manual or a driver. |
1.3.6.1.4.1.2590.1.1.1.5.6.3.1.5 | mltSysOutputTrayType | 0 | 0 | Shows the type of tray in OutputTray. This is an item for judging whether it is MailBin, and it is used in order to judge whether… |