Reference record for OID 1.3.6.1.4.1.2636.3.4.2.1


parent
1.3.6.1.4.1.2636.3.4.2 (jnxCraftAlarms)
node code
1
node name
jnxAlarmRelayMode
dot oid
1.3.6.1.4.1.2636.3.4.2.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) juniperMIB(2636) jnxMibs(3) jnxAlarms(4) jnxCraftAlarms(2) jnxAlarmRelayMode(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) juniperMIB(2636) jnxMibs(3) jnxAlarms(4) jnxCraftAlarms(2) jnxAlarmRelayMode(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) juniperMIB(2636) jnxMibs(3) jnxAlarms(4) jnxCraftAlarms(2) jnxAlarmRelayMode(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) juniperMIB(2636) jnxMibs(3) jnxAlarms(4) jnxCraftAlarms(2) jnxAlarmRelayMode(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) juniperMIB(2636) jnxMibs(3) jnxAlarms(4) jnxCraftAlarms(2) jnxAlarmRelayMode(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) juniperMIB(2636) jnxMibs(3) jnxAlarms(4) jnxCraftAlarms(2) jnxAlarmRelayMode(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/juniperMIB/jnxMibs/jnxAlarms/jnxCraftAlarms/jnxAlarmRelayMode
  • /iso/identified-organization/dod/internet/private/enterprises/juniperMIB/jnxMibs/jnxAlarms/jnxCraftAlarms/jnxAlarmRelayMode
  • /iso/org/dod/internet/private/enterprise/juniperMIB/jnxMibs/jnxAlarms/jnxCraftAlarms/jnxAlarmRelayMode
  • /iso/org/dod/internet/private/enterprises/juniperMIB/jnxMibs/jnxAlarms/jnxCraftAlarms/jnxAlarmRelayMode
  • /iso/iso-identified-organization/dod/internet/private/enterprise/juniperMIB/jnxMibs/jnxAlarms/jnxCraftAlarms/jnxAlarmRelayMode
  • /iso/iso-identified-organization/dod/internet/private/enterprises/juniperMIB/jnxMibs/jnxAlarms/jnxCraftAlarms/jnxAlarmRelayMode
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2636/3/4/2/1

    Description by mibdepot

    The alarm relay mode of the craft interface
    panel for both yellow and red alarms.

    Both yellow and red alarms could be cut off
    by a front panel Alarm Cutoff / Lamp Test
    (ACO/LT) button.

    In the pass-on mode, the alarm relay will be
    activated to pass on the yellow or red alarms.
    In the cut-off mode, both yellow and red alarms
    will be cut off from the alarm relays which are
    normally connected to audible sirens or visual
    flashing devices.

    Parsed from file mib-jnx-chassis-alarm_2.txt
    Company: None
    Module: JUNIPER-ALARM-MIB

    Description by circitor

    The alarm relay mode of the craft interface
    panel for both yellow and red alarms.

    Both yellow and red alarms could be cut off
    by a front panel Alarm Cutoff / Lamp Test
    (ACO/LT) button.

    In the pass-on mode, the alarm relay will be
    activated to pass on the yellow or red alarms.
    In the cut-off mode, both yellow and red alarms
    will be cut off from the alarm relays which are
    normally connected to audible sirens or visual
    flashing devices.

    Parsed from file JUNIPER-ALARM-MIB.mib
    Module: JUNIPER-ALARM-MIB

    Information by oid_info

    Vendor: Juniper Networks, Inc.
    Module: JUNIPER-ALARM-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    jnxAlarmRelayMode OBJECT-TYPE SYNTAX INTEGER { other(1), passOn(2), cutOff(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm relay mode of the craft interface panel for both yellow and red alarms. Both yellow and red alarms could be cut off by a front panel Alarm Cutoff / Lamp Test (ACO/LT) button. In the pass-on mode, the alarm relay will be activated to pass on the yellow or red alarms. In the cut-off mode, both yellow and red alarms will be cut off from the alarm relays which are normally connected to audible sirens or visual flashing devices." ::= { jnxCraftAlarms 1 }

    Information by circitor

    jnxAlarmRelayMode OBJECT-TYPE SYNTAX INTEGER { other(1), passOn(2), cutOff(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm relay mode of the craft interface panel for both yellow and red alarms. Both yellow and red alarms could be cut off by a front panel Alarm Cutoff / Lamp Test (ACO/LT) button. In the pass-on mode, the alarm relay will be activated to pass on the yellow or red alarms. In the cut-off mode, both yellow and red alarms will be cut off from the alarm relays which are normally connected to audible sirens or visual flashing devices." ::= { jnxCraftAlarms 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2636)

    Cheng Jeff

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2636.3.4.2.1.0 jnxAlarmRelayMode 0 0 None

    Brothers (2)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2636.3.4.2.2 jnxYellowAlarms 3 6 None
    1.3.6.1.4.1.2636.3.4.2.3 jnxRedAlarms 3 6 None