This table provides a set of calculated values for each
RPM entry, for each collection of probes maintained within that
entry, and for each supported measurement set within that
collection of probes.
Note, not all collection types will be available for every
RPM Entry (identified by pingCtlOwnerIndex/pingCtlTestName).
The jitter calculations are available only for those RPM entries
that employ hardware timestamps. Further, the ingress & egress
calculations are available only for those probe types that
measure one-way delays or where hardware timestamps are
employed and the one-way-hardware timestamp knob is enabled.
In either case, the one-way delays must be less than the round
trip times, otherwise they are discarded.
Also, this table will skip over any measurement set for which
there are 0 samples.
Parsed from file mib-jnx-rpm.txt
Company: None
Module: JUNIPER-RPM-MIB
This table provides a set of calculated values for each
RPM entry, for each collection of probes maintained within that
entry, and for each supported measurement set within that
collection of probes.
Note, not all collection types will be available for every
RPM Entry (identified by pingCtlOwnerIndex/pingCtlTestName).
The jitter calculations are available only for those RPM entries
that employ hardware timestamps. Further, the ingress & egress
calculations are available only for those probe types that
measure one-way delays or where hardware timestamps are
employed and the one-way-hardware timestamp knob is enabled.
In either case, the one-way delays must be less than the round
trip times, otherwise they are discarded.
Also, this table will skip over any measurement set for which
there are 0 samples.
Parsed from file JUNIPER-RPM-MIB.mib
Module: JUNIPER-RPM-MIB
Vendor: Juniper Networks, Inc.
Module: JUNIPER-RPM-MIB
[Automatically extracted from oidview.com]
jnxRpmResultsCalculatedTable OBJECT-TYPE SYNTAX SEQUENCE OF JnxRpmResultsCalculatedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides a set of calculated values for each RPM entry, for each collection of probes maintained within that entry, and for each supported measurement set within that collection of probes. Note, not all collection types will be available for every RPM Entry (identified by pingCtlOwnerIndex/pingCtlTestName). The jitter calculations are available only for those RPM entries that employ hardware timestamps. Further, the ingress & egress calculations are available only for those probe types that measure one-way delays or where hardware timestamps are employed and the one-way-hardware timestamp knob is enabled. In either case, the one-way delays must be less than the round trip times, otherwise they are discarded. Also, this table will skip over any measurement set for which there are 0 samples." ::= { jnxRpmMib 3 }
jnxRpmResultsCalculatedTable OBJECT-TYPE SYNTAX SEQUENCE OF JnxRpmResultsCalculatedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides a set of calculated values for each RPM entry, for each collection of probes maintained within that entry, and for each supported measurement set within that collection of probes. Note, not all collection types will be available for every RPM Entry (identified by pingCtlOwnerIndex/pingCtlTestName). The jitter calculations are available only for those RPM entries that employ hardware timestamps. Further, the ingress & egress calculations are available only for those probe types that measure one-way delays or where hardware timestamps are employed and the one-way-hardware timestamp knob is enabled. In either case, the one-way delays must be less than the round trip times, otherwise they are discarded. Also, this table will skip over any measurement set for which there are 0 samples." ::= { jnxRpmMib 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2636.3.50.1.3.1 | jnxRpmResultsCalculatedEntry | 8 | 8 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2636.3.50.1.1 | jnxRpmResultsSampleTable | 1 | 5 | This table provides measurements from the latest individual RPM probe samples. Within each sample, the specific measurement typ… |
1.3.6.1.4.1.2636.3.50.1.2 | jnxRpmResultsSummaryTable | 1 | 6 | This table provides a summary of the results for a specific RPM entry (identified by pingCtlOwnerIndex/pingCtlTestName). The scop… |
1.3.6.1.4.1.2636.3.50.1.4 | jnxRpmHistorySampleTable | 1 | 4 | This table provides measurements for individual RPM probe samples. In addition to the last completed sample, a configurable numb… |
1.3.6.1.4.1.2636.3.50.1.5 | jnxRpmHistorySummaryTable | 1 | 5 | This table provides historical summary data for each collection of probes within each RPM Entry, similar to the jnxRpmResultsSumm… |
1.3.6.1.4.1.2636.3.50.1.6 | jnxRpmHistoryCalculatedTable | 1 | 9 | This table provides a set of calculated values for each RPM entry, for each collection of probes maintained within that entry, an… |