This notification is generated when the
bfdSessState object for one or more contiguous
entries in bfdSessTable are about to enter the up(2)
state from some other state. The included values of
bfdSessDiag MUST both be set equal to this
new state (i.e: up(1)). The two instances of
bfdSessDiag in this notification indicate the range
of indexes that are affected. Note that all the indexes
of the two ends of the range can be derived from the
instance identifiers of these two objects. For the
cases where a contiguous range of sessions
have transitioned into the up(1) state at roughly
the same time, the device SHOULD issue a single
notification for each range of contiguous indexes in
an effort to minimize the emission of a large number
of notifications. If a notification has to be
issued for just a single bfdSessEntry, then
the instance identifier (and values) of the two
bfdSessDiag objects MUST be the identical.
Parsed from file mib-jnx-bfd-exp.txt
Company: None
Module: BFD-STD-MIB
This notification is generated when the
bfdSessState object for one or more contiguous
entries in bfdSessTable are about to enter the up(2)
state from some other state. The included values of
bfdSessDiag MUST both be set equal to this
new state (i.e: up(1)). The two instances of
bfdSessDiag in this notification indicate the range
of indexes that are affected. Note that all the indexes
of the two ends of the range can be derived from the
instance identifiers of these two objects. For the
cases where a contiguous range of sessions
have transitioned into the up(1) state at roughly
the same time, the device SHOULD issue a single
notification for each range of contiguous indexes in
an effort to minimize the emission of a large number
of notifications. If a notification has to be
issued for just a single bfdSessEntry, then
the instance identifier (and values) of the two
bfdSessDiag objects MUST be the identical.
Parsed from file BFD-STD-MIB.mib
Module: BFD-STD-MIB
Vendor: Juniper Networks, Inc.
Module: BFD-STD-MIB
[Automatically extracted from oidview.com]
bfdSessUp NOTIFICATION-TYPE OBJECTS { bfdSessDiag, bfdSessDiag } STATUS current DESCRIPTION "This notification is generated when the bfdSessState object for one or more contiguous entries in bfdSessTable are about to enter the up(2) state from some other state. The included values of bfdSessDiag MUST both be set equal to this new state (i.e: up(1)). The two instances of bfdSessDiag in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For the cases where a contiguous range of sessions have transitioned into the up(1) state at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single bfdSessEntry, then the instance identifier (and values) of the two bfdSessDiag objects MUST be the identical." ::= { bfdNotifications 1 }
bfdSessUp NOTIFICATION-TYPE OBJECTS { bfdSessDiag, bfdSessDiag } STATUS current DESCRIPTION "This notification is generated when the bfdSessState object for one or more contiguous entries in bfdSessTable are about to enter the up(2) state from some other state. The included values of bfdSessDiag MUST both be set equal to this new state (i.e: up(1)). The two instances of bfdSessDiag in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For the cases where a contiguous range of sessions have transitioned into the up(1) state at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single bfdSessEntry, then the instance identifier (and values) of the two bfdSessDiag objects MUST be the identical." ::= { bfdNotifications 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2636.5.3.1.0.2 | bfdSessDown | 0 | 0 | This notification is generated when the bfdSessState object for one or more contiguous entries in bfdSessTable are about to enter… |