In the case of a testFailTrap or a measurementFailTrap,
at the moment when the trap is generated, the value of
the '...LatestError' object associated with the test which
caused the trap is copied here. In the case of a
measurementUnknownTrap, the time at which the measurement
became unknown is copied here.
This object is present for the formal purpose of defining
the variable bindings returned with the traps. It is not
accessible for normal reading.
Parsed from file DVB-MGTR101290-MIB.mib
Module: DVB-MGTR101290-MIB
Vendor: Digital Video Broadcasting (DVB)
Module: DVB-MGTR101290-MIB
[Automatically extracted from oidview.com]
trapControlGenerationTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "In the case of a testFailTrap or a measurementFailTrap, at the moment when the trap is generated, the value of the '...LatestError' object associated with the test which caused the trap is copied here. In the case of a measurementUnknownTrap, the time at which the measurement became unknown is copied here. This object is present for the formal purpose of defining the variable bindings returned with the traps. It is not accessible for normal reading." ::= { trapControlEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2696.3.2.1.2.1.1.1 | trapControlInputNumber | 0 | 0 | Each Transport Stream input has separate trap control parameters. This object identifies the Transport Stream input to which the … |
1.3.6.1.4.1.2696.3.2.1.2.1.1.2 | trapControlOID | 0 | 0 | In the case of a testFailTrap or a measurementFailTrap, this object holds the OID of the '...State' or '...TestState' object whos… |
1.3.6.1.4.1.2696.3.2.1.2.1.1.4 | trapControlMeasurementValue | 0 | 0 | At the moment when a measurementFailTrap is generated, the value of this object is set from the '...Value' object associated with… |
1.3.6.1.4.1.2696.3.2.1.2.1.1.5 | trapControlRateStatus | 0 | 0 | This object is used for rate control of traps, preventing overload of the management network by transmission of an excessive numb… |
1.3.6.1.4.1.2696.3.2.1.2.1.1.6 | trapControlPeriod | 0 | 0 | An agent will ensure that the interval between sending traps is no shorter than this time period. The management system can overr… |
1.3.6.1.4.1.2696.3.2.1.2.1.1.7 | trapControlFailureSummary | 0 | 0 | This bit string contains a summary of all the test failures. If the bit for the test is set to one, that test is in a fail state.… |