'tau' value for Service bit rate measurement. When a
manager sets the value of this object, the values of
the tsMeasurePrefPIDBitRateTau columns in all the rows
of the tsMeasurePreferencesPIDTable are set to this
same value. This also becomes the default value
for any new rows created subsequently.
See note in description for tsMeasurePrefTSBitRateTau.
Parsed from file DVB-MGTR101290-MIB.mib
Module: DVB-MGTR101290-MIB
Vendor: Digital Video Broadcasting (DVB)
Module: DVB-MGTR101290-MIB
[Automatically extracted from oidview.com]
tsMeasurePrefAllPIDBitRateTau OBJECT-TYPE SYNTAX FloatingPoint UNITS "second" MAX-ACCESS read-write STATUS current DESCRIPTION "'tau' value for Service bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefPIDBitRateTau columns in all the rows of the tsMeasurePreferencesPIDTable are set to this same value. This also becomes the default value for any new rows created subsequently. See note in description for tsMeasurePrefTSBitRateTau." REFERENCE "TR 101 290 section 5.3.3.1" DEFVAL { "0.1" } ::= { tsMeasurePreferencesEntry 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.1 | tsMeasurePrefInputNumber | 0 | 0 | Transport Stream input to which the preferences apply |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.2 | tsMeasurePrefPCRDemarcationFrequency | 0 | 0 | This is the demarcation frequency used by the PCR measurement system to distinguish between inaccuracy/jitter and drift. |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.3 | tsMeasurePrefPCRFOMax | 0 | 0 | Maximum permitted PCR_FO (frequency offset). An error is indicated if the measured PCR_FO is outside the range [-tsMeasurePrefPC… |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.4 | tsMeasurePrefPCRDRMax | 0 | 0 | Maximum permitted PCR_DR (drift rate). An error is indicated if the measured PCR_DR is outside the range [-tsMeasurePrefPCRDRMax… |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.5 | tsMeasurePrefPCROJMax | 0 | 0 | Maximum permitted PCR_OJ (overall jitter). An error is indicated if the measured PCR_OJ is outside the range [-tsMeasurePrefPCRO… |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.6 | tsMeasurePrefTSBitRateTau | 0 | 0 | tsMeasurePreftSBitRateTau |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.7 | tsMeasurePrefTSBitRateN | 0 | 0 | tsMeasurePreftSBitRateN |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.8 | tsMeasurePrefTSBitRateElement | 0 | 0 | tsMeasurePreftSBitRateElement |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.9 | tsMeasurePrefTSBitRateMin | 0 | 0 | tsMeasurePreftSBitRateMin |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.10 | tsMeasurePrefTSBitRateMax | 0 | 0 | tsMeasurePreftSBitRateMax |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.11 | tsMeasurePrefAllServiceBitRateTau | 0 | 0 | 'tau' value for Service bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefServic… |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.12 | tsMeasurePrefAllServiceBitRateN | 0 | 0 | 'N' value for Service bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefService… |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.13 | tsMeasurePrefAllServiceBitRateElement | 0 | 0 | Data unit which is counted by the bit rate measurement algorithm for services. When a manager sets the value of this object, the … |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.15 | tsMeasurePrefAllPIDBitRateN | 0 | 0 | 'N' value for PID bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefPIDBitRateN… |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.16 | tsMeasurePrefAllPIDBitRateElement | 0 | 0 | Data unit which is counted by the bit rate measurement algorithm for PIDs. When a manager sets the value of this object, the valu… |
1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.17 | tsMeasurePrefExpectedTSID | 0 | 0 | This object defines the expected Transport Stream ID that is compared with the actual ID to perform the consistency of informatio… |