Reference record for OID 1.3.6.1.4.1.272.4.17.3.1


parent
1.3.6.1.4.1.272.4.17.3 (x8)
node code
1
node name
sysX8Config
dot oid
1.3.6.1.4.1.272.4.17.3.1
type
OBJECT IDENTIFIER
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) bintec(272) bibo(4) sys(17) x8(3) sysX8Config(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) bintec(272) bibo(4) sys(17) x8(3) sysX8Config(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) bintec(272) bibo(4) sys(17) x8(3) sysX8Config(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) bintec(272) bibo(4) sys(17) x8(3) sysX8Config(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) bintec(272) bibo(4) sys(17) x8(3) sysX8Config(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) bintec(272) bibo(4) sys(17) x8(3) sysX8Config(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/bintec/bibo/sys/x8/sysX8Config
  • /iso/identified-organization/dod/internet/private/enterprises/bintec/bibo/sys/x8/sysX8Config
  • /iso/org/dod/internet/private/enterprise/bintec/bibo/sys/x8/sysX8Config
  • /iso/org/dod/internet/private/enterprises/bintec/bibo/sys/x8/sysX8Config
  • /iso/iso-identified-organization/dod/internet/private/enterprise/bintec/bibo/sys/x8/sysX8Config
  • /iso/iso-identified-organization/dod/internet/private/enterprises/bintec/bibo/sys/x8/sysX8Config
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/272/4/17/3/1

    Information by oid_info

    Vendor: Bintec
    Module: BIANCA-X8000-MIBSYS-MIB (mibsysx8.mib)
    Type: OBJ ID
    Access:
    Syntax:

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    sysX8Config OBJECT IDENTIFIER ::= { x8 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.272)

    Hertlein Elisabeth

    Children (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.272.4.17.3.1.1 sysX8ConfigPowerSupply1State 1 1 This variable shows the state of the power supply.
    1.3.6.1.4.1.272.4.17.3.1.2 sysX8ConfigPowerSupply1Temp 1 1 This variable shows the actual power supply temperature
    in the unit Celsius.
    1.3.6.1.4.1.272.4.17.3.1.3 sysX8ConfigPowerSupply1TempAlarmThreshold 1 1 Power supply 1 temperature threshold.
    1.3.6.1.4.1.272.4.17.3.1.4 sysX8ConfigPowerSupply1TempAlarmTrap 1 1 If the power supply temperature raises above the threshold,
    a alarm trap is generated every 60 seconds.
    1.3.6.1.4.1.272.4.17.3.1.5 sysX8ConfigPowerSupply2State 1 1 This variable show the the state of the power supply.
    1.3.6.1.4.1.272.4.17.3.1.6 sysX8ConfigPowerSupply2Temp 1 1 This variable shows the actual power supply temperature
    in the unit Celsius.
    1.3.6.1.4.1.272.4.17.3.1.7 sysX8ConfigPowerSupply2TempAlarmThreshold 1 1 Power supply 2 temperature threshold.
    1.3.6.1.4.1.272.4.17.3.1.8 sysX8ConfigPowerSupply2TempAlarmTrap 1 1 If the power supply temperature raises above the threshold,
    a alarm trap is generated every 60 seconds.
    1.3.6.1.4.1.272.4.17.3.1.9 sysX8ConfigFanControl 1 1 This variable defines automatic fan control.
    In mode 'auto' the fans are automatically adjusted
    depending on the current temperat…
    1.3.6.1.4.1.272.4.17.3.1.10 sysX8ConfigFanVersion 1 1 This variable shows the firmware version of
    the fan unit.
    1.3.6.1.4.1.272.4.17.3.1.11 sysX8ConfigFan1 1 1 This variable shows the current turning speed.
    1.3.6.1.4.1.272.4.17.3.1.12 sysX8ConfigFan2 1 1 This variable shows the current turning speed.
    1.3.6.1.4.1.272.4.17.3.1.13 sysX8ConfigFan3 1 1 This variable shows the current turning speed.
    1.3.6.1.4.1.272.4.17.3.1.14 sysX8ConfigFan4 1 1 This variable shows the current turning speed.

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.272.4.17.3.2 sysX8Traps 0 0 None