This trap is sent when a module fails and thus is inaccessible.
The value of modFirtSlot will be included in this traps varBind list.
Parsed from file LCPHYSEN.MIB.txt
Company: None
Module: LC-PHYSICAL-ENTITIES-MIB
This trap is sent when a module fails and thus is inaccessible.
The value of modFirtSlot will be included in this traps varBind list.
Parsed from file LC-PHYSICAL-ENTITIES-MIB.mib
Module: LC-PHYSICAL-ENTITIES-MIB
Vendor: LANCAST, Inc.
Module: LC-PHYSICAL-ENTITIES-MIB
[Automatically extracted from oidview.com]
moduleFailure NOTIFICATION-TYPE OBJECTS { modFirstSlot } STATUS current DESCRIPTION "This trap is sent when a module fails and thus is inaccessible. The value of modFirtSlot will be included in this traps varBind list." ::= { lancastTraps 23 }
moduleFailure NOTIFICATION-TYPE OBJECTS { modFirstSlot } STATUS current DESCRIPTION "This trap is sent when a module fails and thus is inaccessible. The value of modFirtSlot will be included in this traps varBind list." ::= { lancastTraps 23 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2745.1.0.10 | entConfigChange | 0 | 0 | An entConfigChange trap is sent when the value of entLastChangeTime changes. It can be utilized by an NMS to trigger logical/phys… |
1.3.6.1.4.1.2745.1.0.11 | tempStatusChange | 0 | 0 | This trap will be sent when the temperature falls outside of the exceptable range. The values of chassisEntityIndex, chassisCurr… |
1.3.6.1.4.1.2745.1.0.12 | backPlaneFailure | 0 | 0 | This trap will be sent when there is a backplane failure. The value of modFirstSlot will be included in this traps varBind list. |
1.3.6.1.4.1.2745.1.0.13 | powerSupply5vChange | 0 | 0 | This trap will be sent when the voltage from the 5 volt power supply falls outside of the exceptable range. The values of power… |
1.3.6.1.4.1.2745.1.0.14 | powerSupplyStatusChange | 0 | 0 | This trap will be sent when a power supply is either turned on or off. The values of powerSupplyEntityIndex, powerSupplyStatus a… |
1.3.6.1.4.1.2745.1.0.15 | powerSupplyInsertion | 0 | 0 | This trap will be sent when a power supply is inserted. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUni… |
1.3.6.1.4.1.2745.1.0.16 | powerSupplyRemoval | 0 | 0 | This trap will be sent when a power supply is removed. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUnit… |
1.3.6.1.4.1.2745.1.0.17 | chassisEntityReset | 0 | 0 | This trap is sent when a chassis is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime … |
1.3.6.1.4.1.2745.1.0.18 | moduleEntityReset | 0 | 0 | This trap is sent when a module is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, m… |
1.3.6.1.4.1.2745.1.0.19 | eportEntityReset | 0 | 0 | This trap is sent when a port is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, mod… |
1.3.6.1.4.1.2745.1.0.20 | moduleInsertion | 0 | 0 | This trap is sent when a module is inserted to a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied w… |
1.3.6.1.4.1.2745.1.0.21 | moduleRemoval | 0 | 0 | This trap is sent when a module is removed from a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied… |
1.3.6.1.4.1.2745.1.0.22 | unknownModule | 0 | 0 | This trap is sent when a module is inserted and it's type cannot be determined. The values of modEntityIndex, modType, modFir… |
1.3.6.1.4.1.2745.1.0.24 | ePortLinkStatusChange | 0 | 0 | This trap is sent when there is a change in the link state of a port. The values of ePortLinkStatus, ePortIndex, modType, modFir… |
1.3.6.1.4.1.2745.1.0.25 | ePortAdminChange | 0 | 0 | This trap is sent when a user changes the admin state of a port from enable to disable or vice versa. The values of ePortAdminS… |
1.3.6.1.4.1.2745.1.0.26 | rtwSwitchOverChange | 0 | 0 | This trap is sent when a switchover from the primary to the secondary port and vice versa has occured. The values of rtwEntityIn… |