Reference record for OID 1.3.6.1.4.1.2785.2.3.6.1.3.0



parent
1.3.6.1.4.1.2785.2.3.6.1.3 (acSonetLine)
node code
0
node name
acSonetLineTraps
dot oid
1.3.6.1.4.1.2785.2.3.6.1.3.0
type
OBJECT IDENTIFIER
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) appian(2785) acOsap(2) acPport(3) acSonet(6) acSonetObjects(1) acSonetLine(3) acSonetLineTraps(0)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) appian(2785) acOsap(2) acPport(3) acSonet(6) acSonetObjects(1) acSonetLine(3) acSonetLineTraps(0)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) appian(2785) acOsap(2) acPport(3) acSonet(6) acSonetObjects(1) acSonetLine(3) acSonetLineTraps(0)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) appian(2785) acOsap(2) acPport(3) acSonet(6) acSonetObjects(1) acSonetLine(3) acSonetLineTraps(0)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) appian(2785) acOsap(2) acPport(3) acSonet(6) acSonetObjects(1) acSonetLine(3) acSonetLineTraps(0)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) appian(2785) acOsap(2) acPport(3) acSonet(6) acSonetObjects(1) acSonetLine(3) acSonetLineTraps(0)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/appian/acOsap/acPport/acSonet/acSonetObjects/acSonetLine/acSonetLineTraps
  • /iso/identified-organization/dod/internet/private/enterprises/appian/acOsap/acPport/acSonet/acSonetObjects/acSonetLine/acSonetLineTraps
  • /iso/org/dod/internet/private/enterprise/appian/acOsap/acPport/acSonet/acSonetObjects/acSonetLine/acSonetLineTraps
  • /iso/org/dod/internet/private/enterprises/appian/acOsap/acPport/acSonet/acSonetObjects/acSonetLine/acSonetLineTraps
  • /iso/iso-identified-organization/dod/internet/private/enterprise/appian/acOsap/acPport/acSonet/acSonetObjects/acSonetLine/acSonetLineTraps
  • /iso/iso-identified-organization/dod/internet/private/enterprises/appian/acOsap/acPport/acSonet/acSonetObjects/acSonetLine/acSonetLineTraps
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2785/2/3/6/1/3/0

    Information by oid_info

    Vendor: Tecnopro SA
    Module: APPIAN-PPORT-SONET-TRAP-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    acSonetLineTraps OBJECT IDENTIFIER ::= { acSonetLine 0 }

    Information by circitor

    acSonetLineTraps OBJECT IDENTIFIER ::= { acSonetLine 0 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2785)

    Pagola Hugo A.

    Children (30)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2785.2.3.6.1.3.0.1 acSonetLineAISAlarmTrap 0 0 AIS detected at line level.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.2 acSonetLineAISClearTrap 0 0 AIS cleared at line level.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.3 acSonetLineRDIAlarmTrap 0 0 RDI detected at line level.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.4 acSonetLineRDIClearTrap 0 0 RDI cleared at line level.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.5 acSonetLine15MinuteESAlarmTrap 0 0 Errored seconds for the line have exceeded the threshold for the
    current 15 minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.6 acSonetLine15MinuteESClearTrap 0 0 Errored seconds for the line have recovered for the current
    15 minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.7 acSonetLine15MinuteSESAlarmTrap 0 0 Severely errored seconds for the line have exceeded the threshold
    for the current 15 minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.8 acSonetLine15MinuteSESClearTrap 0 0 Severely errored seconds for the line have recovered for the current
    15 minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.9 acSonetLine15MinuteCVAlarmTrap 0 0 BIP errors for the line have exceeded the threshold for the
    current 15 minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.10 acSonetLine15MinuteCVClearTrap 0 0 BIP errors for the line have recovered for the current 15 minute
    interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.11 acSonetLine15MinuteUASAlarmTrap 0 0 Unavailable seconds for the line have exceeded the threshold for
    the current 15 minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.12 acSonetLine15MinuteUASClearTrap 0 0 Unavailable seconds for the line have recovered for the current 15
    minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.13 acSonetLineDayESAlarmTrap 0 0 Errored seconds for the line have exceeded the threshold for the
    current 15 minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.14 acSonetLineDayESClearTrap 0 0 Errored seconds for the line have recovered for the current
    day interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.15 acSonetLineDaySESAlarmTrap 0 0 Severely errored seconds for the line have exceeded the threshold
    for the current day interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.16 acSonetLineDaySESClearTrap 0 0 Severely errored seconds for the line have recovered for the current
    day interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.17 acSonetLineDayCVAlarmTrap 0 0 BIP errors for the line have exceeded the threshold for the
    current day interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.18 acSonetLineDayCVClearTrap 0 0 BIP errors for the line have recovered for the current day
    interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.19 acSonetLineDayUASAlarmTrap 0 0 Unavailable seconds for the line have exceeded the threshold for
    the current day interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.20 acSonetLineDayUASClearTrap 0 0 Unavailable seconds for the line have recovered for the current 15
    minute interval.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.21 acSonetLineProtectionSwitchAlarmTrap 0 0 Protection switch is currently active on this SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.22 acSonetLineProtectionSwitchClearTrap 0 0 Protection switch has been released on this SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.23 acSonetLineProtectionFailureAlarmTrap 0 0 Protection switch failure has occured for this SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.24 acSonetLineProtectionFailureClearTrap 0 0 Protection switch failure has cleared for this SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.25 acSonetLineProtectionChannelMismatchAlarmTrap 0 0 A protection switching channel mismatch failure has occured on the
    SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.26 acSonetLineProtectionChannelMismatchClearTrap 0 0 A protection switching channel mismatch failure has cleared on the
    SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.27 acSonetLineProtectionModeMismatchAlarmTrap 0 0 A protection switching mode mismatch failure has occured on the
    SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.28 acSonetLineProtectionModeMismatchClearTrap 0 0 A protection switching mode mismatch failure has cleared on the
    SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.29 acSonetLineProtectionSwitchingByteFailureAlarmTrap 0 0 A protection switching byte failure has been detected on the
    SONET interface.
    1.3.6.1.4.1.2785.2.3.6.1.3.0.30 acSonetLineProtectionSwitchingByteFailureClearTrap 0 0 A protection switching byte failure has been cleared on the
    SONET interface.

    Brothers (4)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2785.2.3.6.1.3.1 acSonetLine15MinuteIntervalTable 1 13 The SONET/SDH Line 15Minute Interval Table.
    1.3.6.1.4.1.2785.2.3.6.1.3.2 acSonetLineDayIntervalTable 1 13 The SONET/SDH Line Day Interval Table.
    1.3.6.1.4.1.2785.2.3.6.1.3.3 acSonetLineThresholdTable 1 10 The SONET/SDH Line Threshold Table.
    1.3.6.1.4.1.2785.2.3.6.1.3.4 acSonetLineProtectionTable 1 17 The SONET/SDH Line Protection table.