An entry in the active alarm table.
Parsed from file nortel-optera-pub.mib.txt
Company: nortel
Module: NORTEL-OPTERA-PUB-MIB
Vendor: Nortel Networks
Module: NORTEL-OPTERA-PUB-MIB (nortel-optera-pub.mib)
Type: ENTRY
Access: not-accessible
Syntax: NotifActiveAlarmTableEntry
Automatically extracted from www.mibdepot.com
notifActiveAlarmTableEntry OBJECT-TYPE SYNTAX NotifActiveAlarmTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the active alarm table." INDEX { notifActiveAlarmLocation, notifActiveAlarmId } ::= { notifActiveAlarmTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2865.1.6.7.1.1 | notifActiveAlarmLocation | 0 | 0 | Location related to this alarm. It specifies the index into the notifAlarmTable and is used to look up all of the alarm informati… |
1.3.6.1.4.1.2865.1.6.7.1.2 | notifActiveAlarmId | 0 | 0 | Specifies the index into the notifAlarmTable for this alarm. This value is used to look up all of the alarm information pertaini… |
1.3.6.1.4.1.2865.1.6.7.1.3 | notifActiveAlarmState | 0 | 0 | Specifies the current state of this alarm. Enumeration is like this: undefined(0), clear(1), intermittent(2), active(3) |
1.3.6.1.4.1.2865.1.6.7.1.4 | notifActiveAlarmSrvcAffectingDesignation | 0 | 0 | Specifies service-affecting designation. It can be undetermined, affecting, non-affecting or maximum service affecting. Enumerati… |
1.3.6.1.4.1.2865.1.6.7.1.5 | notifActiveAlarmCardType | 0 | 0 | Specifies the provisioned card type of this alarm. If the card type is not applicable, it is set to undefine(0). Where enumerati… |
1.3.6.1.4.1.2865.1.6.7.1.6 | notifActiveAlarmSeverity | 0 | 0 | The severity of this alarm. Enumeration is like this: undefined(0), critical(1), major(2), minor(3), alert(4) |
1.3.6.1.4.1.2865.1.6.7.1.7 | notifActiveAlarmTimeStamp | 0 | 0 | Specifies the time and date when this alarm last changed state. |
1.3.6.1.4.1.2865.1.6.7.1.8 | notifActiveAlarmDescr | 0 | 0 | A text string describing the alarm. |
1.3.6.1.4.1.2865.1.6.7.1.9 | notifLocationDescr | 0 | 0 | A comma-separated string describing the location information about this alarm. It will be in the following format: slot:<>, port:<… |
1.3.6.1.4.1.2865.1.6.7.1.10 | notifOptSysId | 0 | 0 | Optical System Id descriptor. It is a string that is up to 8 character long for line cards and up to 17 character for OSC. |
1.3.6.1.4.1.2865.1.6.7.1.11 | notifActiveAlarmPathList | 0 | 0 | A comma-separated string describes the path information for the current alarm. It returns an empty string in release 7.0. The st… |
1.3.6.1.4.1.2865.1.6.7.1.12 | notifActiveAlarmUpsnNum | 0 | 0 | This value would be applicable if the alarm is raised when UPSN is enabled on the shelf. It would be 0 otherwise. |