For ISUP service profiles, specifies the type of continuity
test to perform, based on the configuration of the remote
switch or trunk connection. The remoteLoopback test is used
when the remote switch will loop back channel being tested.
The remote2Wire test is used when the remote switch supports
the 2 wire continuity test procedure. And the remote4Wire
test mode is used when the remote switch supports the 4 wire
continuity test procedure. The default value is remoteLoopback.
Parsed from file sonusNrm.mib.txt
Company: None
Module: SONUS-NODE-RESOURCES-MIB
For ISUP service profiles, specifies the type of continuity
test to perform, based on the configuration of the remote
switch or trunk connection. The remoteLoopback test is used
when the remote switch will loop back channel being tested.
The remote2Wire test is used when the remote switch supports
the 2 wire continuity test procedure. And the remote4Wire
test mode is used when the remote switch supports the 4 wire
continuity test procedure. The default value is remoteLoopback.
Parsed from file SONUS-NODE-RESOURCES-MIB.mib
Module: SONUS-NODE-RESOURCES-MIB
Vendor: Sonus Networks, Inc.
Module: SONUS-NODE-RESOURCES-MIB
[Automatically extracted from oidview.com]
sonusCktServProfileCttTestType OBJECT-TYPE SYNTAX INTEGER { remoteLoopback(1), remote2Wire(2), remote4Wire(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "For ISUP service profiles, specifies the type of continuity test to perform, based on the configuration of the remote switch or trunk connection. The remoteLoopback test is used when the remote switch will loop back channel being tested. The remote2Wire test is used when the remote switch supports the 2 wire continuity test procedure. And the remote4Wire test mode is used when the remote switch supports the 4 wire continuity test procedure. The default value is remoteLoopback." DEFVAL { remoteLoopback } ::= { sonusCktServProfileEntry 7 }
sonusCktServProfileCttTestType OBJECT-TYPE SYNTAX INTEGER { remoteLoopback(1), remote2Wire(2), remote4Wire(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "For ISUP service profiles, specifies the type of continuity test to perform, based on the configuration of the remote switch or trunk connection. The remoteLoopback test is used when the remote switch will loop back channel being tested. The remote2Wire test is used when the remote switch supports the 2 wire continuity test procedure. And the remote4Wire test mode is used when the remote switch supports the 4 wire continuity test procedure. The default value is remoteLoopback." DEFVAL { remoteLoopback } ::= { sonusCktServProfileEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.1 | sonusCktServProfileIndex | 0 | 0 | Identifies the target circuit service profile entry. |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.2 | sonusCktServProfileState | 0 | 0 | The administrative state of this circuit service profile entry. |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.3 | sonusCktServProfileName | 0 | 0 | The name of this circuit service profile. |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.4 | sonusCktServProfileAudioEncoding | 0 | 0 | The audio encoding method to be performed on the voice data received from, and destined to the PSTN. The default encoding method … |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.5 | sonusCktServProfileBandwidth | 0 | 0 | The number of DS0 channels to group for Nx64 connections. Valid entries are 1 to 24 channels, allowing up to a complete set of T1… |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.6 | sonusCktServProfileNecEnable | 0 | 0 | Specifies whether Network Echo Cancellation (NEC) is enabled for the channel. When enabled, NEC is enabled acording to the approp… |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.8 | sonusCktServProfileCttTimeout | 0 | 0 | For ISUP service profiles, specifies the overall test timeout value. The continuity test will be declared failed if the continuit… |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.9 | sonusCktServProfileCttMinDetectTime | 0 | 0 | For ISUP service profiles, specifies the minimum time to detect the presence of the continuity test tone. The minimum detect time… |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.10 | sonusCktServProfileCttMinReleaseTime | 0 | 0 | For ISUP service profiles, specifies the minimum time to detect that the continuity test tone has been removed and is no longer p… |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.11 | sonusCktServProfileCapability | 0 | 0 | Specifies the data capabilities for the circuit. This parameter specifies whether voice only, circuit mode data only, or both vo… |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.12 | sonusCktServProfileDataRestrictedCfg | 0 | 0 | Specifies whether the circuit may support 64 Kbit/s unrestricted data, or if the circuit supports 56 Kbit/s restricted data. |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.13 | sonusCktServProfileDtmfProfileName | 0 | 0 | The name of DTMF profile associated with this circuit service profile. |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.14 | sonusCktServProfileRowStatus | 0 | 0 | None |
1.3.6.1.4.1.2879.2.2.2.1.12.2.1.15 | sonusCktServProfileInterworkingXfrCap | 0 | 0 | The transfer capability for audio calls when interworking with CAS. The default transfer capability is speech. |