Vendor: Sonus Networks, Inc.
Module: SONUS-SS7-SERVICES-MIB
[Automatically extracted from oidview.com]
sonusSs7NodeProfileEntry OBJECT-TYPE SYNTAX SonusSs7NodeProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusSs7NodeProfileIndex } ::= { sonusSs7NodeProfileTable 1 }
sonusSs7NodeProfileEntry OBJECT-TYPE SYNTAX SonusSs7NodeProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusSs7NodeProfileIndex } ::= { sonusSs7NodeProfileTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.1 | sonusSs7NodeProfileIndex | 0 | 0 | Identifies the SS7 Node Profile entry |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.2 | sonusSs7NodeProfileName | 0 | 0 | The name of the Node Profile |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.3 | sonusSs7PointCodeSize | 0 | 0 | Indicates the total number of bits in the point code. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.4 | sonusSs7PointCodeFormatType | 0 | 0 | The Point Code format type being defined. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.5 | sonusSs7ServerProtocol | 0 | 0 | The interface used between the SS7 gateway and the SS7 client on the GSX9000 |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.6 | sonusSs7HandShakeInterval | 0 | 0 | HandShake interval between the client and the server in seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.7 | sonusSs7TimerT1 | 0 | 0 | The Timer T1 could be changed from its default using this entry. The valid ranges are 4 - 15 seconds for ANSI and 15 - 60 Second… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.8 | sonusSs7TimerT2 | 0 | 0 | The Timer T2 could be changed from its default using this entry. The valid value for ITU is 3 Minutes. This timer has no releven… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.9 | sonusSs7TimerT3 | 0 | 0 | The T3 timer is started on receipt of an Overload message in the ITU network. This has no relevence in the ANSI network. The val… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.10 | sonusSs7TimerT4 | 0 | 0 | The Timer T4 could be changed from its default using this entry. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.11 | sonusSs7TimerT5 | 0 | 0 | The T5 Timer is started when the release message is sent. The valid values as per the specifications are 60 seconds for the ANSI… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.12 | sonusSs7TimerT6 | 0 | 0 | The timer T6 is started when the suspend message is received. The valid range for this timer is 10 to 32 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.13 | sonusSs7TimerT7 | 0 | 0 | The Timer T7 could be changed from its default using this entry. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.14 | sonusSs7TimerT8 | 0 | 0 | The T8 timer is timer to be started with continuity check has been indicated in the IAM. The valid range is 10 to 15 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.15 | sonusSs7TimerT9 | 0 | 0 | The Timer T9 started when outgoing international exchange recieves an ACM. The valid range is 120 to 240 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.16 | sonusSs7TimerT10 | 0 | 0 | The Timer T10 is started when the last digit is recived in interworking situations. This timer has no relevence to ANSI. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.17 | sonusSs7TimerT11 | 0 | 0 | The Timer T11 is started when the latest address message is received in interworking situations. The valid range is 15 to 20 sec… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.18 | sonusSs7TimerT12 | 0 | 0 | The Timer T12 is started when a blocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.19 | sonusSs7TimerT13 | 0 | 0 | The Timer T13 is started when the initial blocking messge is sent. The valid value for ANSI is 60 seconds and for ITU is between… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.20 | sonusSs7TimerT14 | 0 | 0 | The Timer T14 is started when an unblocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds … |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.21 | sonusSs7TimerT15 | 0 | 0 | The Timer T15 is started when the initial unblocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 se… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.22 | sonusSs7TimerT16 | 0 | 0 | The Timer T16 is started when the reset circuit is started which was not due to expiry of T5. The valid ranges are 4 to 15 secon… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.23 | sonusSs7TimerT17 | 0 | 0 | The Timer T17 is started when initial reset message is sent. The valid values are 60 seconds for ANSI and 300 to 900 for ITU. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.24 | sonusSs7TimerT18 | 0 | 0 | The Timer T18 is started when circuit group blocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.25 | sonusSs7TimerT19 | 0 | 0 | The Timer T19 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 se… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.26 | sonusSs7TimerT20 | 0 | 0 | The Timer T20 is started when group unblocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 secon… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.27 | sonusSs7TimerT21 | 0 | 0 | The Timer T21 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 se… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.28 | sonusSs7TimerT22 | 0 | 0 | The Timer T22 is started when circuit group reset message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 se… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.29 | sonusSs7TimerT23 | 0 | 0 | The Timer T23 is started when initial group reset message is sent. The valid values are 60 seconds for the ANSI and 300 to 900 s… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.30 | sonusSs7TimerT24 | 0 | 0 | The Timer T24 is started when check tone is sent. The value is less than 2 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.31 | sonusSs7TimerT25 | 0 | 0 | The Timer T25 is started when initial continuity check failure is detected. The range is 1 to 10 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.32 | sonusSs7TimerT26 | 0 | 0 | The Timer T26 is started when a second or subsequent continuity failure is detected. The valid value are 60 to 180 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.33 | sonusSs7TimerT27 | 0 | 0 | The Timer T27 is started when a continuity fail message is recieved. The valid values are more than 180 seconds for ANSI and 240… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.34 | sonusSs7TimerT28 | 0 | 0 | The Timer T28 is started when Circuit Query Message is sent. The valid value is 10 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.35 | sonusSs7TimerT29 | 0 | 0 | The Timer T29 is started when Congestion indication is received when T29 is not running. The valid range is 300 to 600 milli sec… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.36 | sonusSs7TimerT30 | 0 | 0 | The Timer T30 is stared when congestion indication is recieved when T29 is not running. The valid range is 5 to 10 seconds for t… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.37 | sonusSs7TimerT31 | 0 | 0 | The Timer T31 is started on release of ISUP signalling connection based on CO SCCP. The value should be set to greater than 360 … |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.38 | sonusSs7TimerT32 | 0 | 0 | The Timer T32 is started when the first end-to-end message is recived. Under ANSI this timer is started after the response to su… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.39 | sonusSs7TimerT33 | 0 | 0 | The Timer T33 is started when Information Request Message is sent. The valid range is 12 to 15 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.40 | sonusSs7TimerT34 | 0 | 0 | The Timer T34 is started when Loop Back Acknowledgement is sent under ANSI. The Timer T34 is started when segmentation is receiv… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.41 | sonusSs7TimerT35 | 0 | 0 | The Timer T35 is started when the last digit recieved is not an ST digit or the fixed number of digits have been recieved. This … |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.42 | sonusSs7TimerT36 | 0 | 0 | The Timer T36 is started when IAM is recived with a segmentation indication for ANSI. This timer is started when transit or inco… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.43 | sonusSs7TimerT37 | 0 | 0 | The Timer T37 is started when User Part Availability test is started under ANSI. This timer is started when a request for and Ec… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.44 | sonusSs7TimerT38 | 0 | 0 | The Timer T38 is started when a suspend message is sent to the preceding switch. This timer is only relevent under ITU. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.45 | sonusSs7TimerT39 | 0 | 0 | The Timer T39 is started when MCID request is sent. It is only relevent in the ITU. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.46 | sonusSs7TimerT40 | 0 | 0 | The Timer T40 could be changed from its default using this entry. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.47 | sonusSs7TimerTAcc | 0 | 0 | Automatic Congestion Control Timer as per ANSI T1.113.4 - 1995. The value of the timer is 5 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.48 | sonusSs7TimerTCcr | 0 | 0 | Continuity Check Request Timer. The value As per ANSI T1.113.4 - 1995 is 2 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.49 | sonusSs7TimerTCcrr | 0 | 0 | Continuity Check Failed Recived. The value as per ANSI T1.113.4 - 1995 is 20 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.50 | sonusSs7TimerTCgb | 0 | 0 | Timer started on recipt of a Circuit Group Block Message. The value as per ANSI T1.113.4 - 1995 is 5 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.51 | sonusSs7TimerTCra | 0 | 0 | Timer started when Circuit Reservation Acknowledgment is sent. The time value as per ANSI T1.113.4 - 1995 is 20 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.52 | sonusSs7TimerTCrm | 0 | 0 | This timer is started when the circuit reservation message is sent. The value as per ANSI T1.113.4 - 1995 is 3 - 4 Seconds. The … |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.53 | sonusSs7TimerTCvt | 0 | 0 | The Timer T CVT is started when the Circuit Validation Test message is sent. This message is only valid for ANSI. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.54 | sonusSs7TimerTExm | 0 | 0 | The Timer Exm,d is started when IAM is sent to the succeeding network. This timer has no relevence in the ITU. This timer is in … |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.55 | sonusSs7TimerTGrs | 0 | 0 | This timer is started when a circuit group reset message is received. This timer is only relevent in the ANSI network. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.56 | sonusSs7TimerTHga | 0 | 0 | This timer is started on recognition of carrier loss. It is only relevent in ANSI network. The valid range is 0 to 300 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.57 | sonusSs7TimerTScga | 0 | 0 | This timer is started when initial demand continuity check fails in the SCGA group. The valid range for this timer is 0 to 120 s… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.58 | sonusSs7TimerTScgad | 0 | 0 | This timer is started failure of demand continuity check in the SCGA group. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.59 | sonusSs7NodeProfileState | 0 | 0 | The administrative state of this object. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.60 | sonusSs7NodeProfileRowStatus | 0 | 0 | None |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.61 | sonusSs7NodeProfileNetworkInd | 0 | 0 | The setting of the Network Indicator used for this SS7 Node entry. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.62 | sonusSs7SlsBits | 0 | 0 | The number of SLS bits to use |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.63 | sonusSs7TimerTA | 0 | 0 | The Bellcore specific timer TA is started when a RLC message is sent by the switch. The value of this timer is 0 to 1000 millise… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.64 | sonusSs7TimerTBlom | 0 | 0 | The Bellcore specific timer TBlom is started when blocking a circuit due to a BLO, and after any call is released; used to notif… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.65 | sonusSs7TimerTCotd | 0 | 0 | The Bellcore specific timer TCOTd is started when sending IAM requesting continuity check. The value of this timer is in millise… |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.66 | sonusSs7TimerTCotl | 0 | 0 | The Bellcore specific timer TCOTl is started when receiving second COT coded failed, awaiting receipt of CCR. |
1.3.6.1.4.1.2879.2.5.3.1.3.2.1.67 | sonusSs7TimerTSus | 0 | 0 | The Bellcore specific timer TSUS is started when a SUS message is sent by the terminating switch, awaiting called party off-hook… |