A unique identifier for an alarm condition. This
value must remain constant. Value 'noAlarm(37)'
will be returned if no Alarm has occured till the
point of GET operation.
Parsed from file bestpwr.mib.txt
Company: None
Module: BESTPOWER-MIB
A unique identifier for an alarm condition. This
value must remain constant. Value 'noAlarm(37)'
will be returned if no Alarm has occured till the
point of GET operation.
Parsed from file BESTPOWER-MIB.mib
Module: BESTPOWER-MIB
Vendor: Best Power - A Division of General Signal Power Systems
Module: BESTPOWER-MIB
[Automatically extracted from oidview.com]
upsLastKnownAlarm OBJECT-TYPE SYNTAX INTEGER { onBattery(1), lowRuntime(2), nearLowBattery(3), lowBattery(4), highBattery(5), checkBattery(6), replaceBattery(7), checkInverter(8), batteriesDisconnected(9), outputOverload(10), lowAcOut(11), circuitBreakerWarning(12), circuitBreakerShdn(13), bypassOn(14), autoBypass(15), siteWiringFault(16), checkFan(17), highAmbTemp(18), highHSTemp(19), highXFMRTemp(20), highPFMTemp(21), probeMissing(22), checkPowerSupply(23), tapRegulator(24), relayFailure(25), checkFuse(26), checkMOV(27), memoryError(28), callService(29), upsFailed(30), userTest(31), testInProgress(32), diagnosticTestFailed(33), ePO(34), upsOff(35), communicationsLost(36), noAlarm(37) } ACCESS read-only STATUS mandatory DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant. Value 'noAlarm(37)' will be returned if no Alarm has occured till the point of GET operation." ::= { upsAlarm 2 }
upsLastKnownAlarm OBJECT-TYPE SYNTAX INTEGER { onBattery(1), lowRuntime(2), nearLowBattery(3), lowBattery(4), highBattery(5), checkBattery(6), replaceBattery(7), checkInverter(8), batteriesDisconnected(9), outputOverload(10), lowAcOut(11), circuitBreakerWarning(12), circuitBreakerShdn(13), bypassOn(14), autoBypass(15), siteWiringFault(16), checkFan(17), highAmbTemp(18), highHSTemp(19), highXFMRTemp(20), highPFMTemp(21), probeMissing(22), checkPowerSupply(23), tapRegulator(24), relayFailure(25), checkFuse(26), checkMOV(27), memoryError(28), callService(29), upsFailed(30), userTest(31), testInProgress(32), diagnosticTestFailed(33), ePO(34), upsOff(35), communicationsLost(36), noAlarm(37) } ACCESS read-only STATUS mandatory DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant. Value 'noAlarm(37)' will be returned if no Alarm has occured till the point of GET operation." ::= { upsAlarm 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2947.1.8.2.0 | upsLastKnownAlarm | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2947.1.8.1 | upsAlarmsPresent | 1 | 1 | The present number of active alarm conditions. |
1.3.6.1.4.1.2947.1.8.3 | upsAlarmTable | 1 | 4 | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm cond… |
1.3.6.1.4.1.2947.1.8.4 | upsWellKnownAlarms | 36 | 72 | None |