Reference record for OID 1.3.6.1.4.1.318.1.1.1.13.4.14.1.3



parent
1.3.6.1.4.1.318.1.1.1.13.4.14.1 (upsDiagSubSysSystemPowerSupplyEntry)
node code
3
node name
upsDiagSubSysSystemPowerSupplyStatus
dot oid
1.3.6.1.4.1.318.1.1.1.13.4.14.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsDiagnostics(13) upsDiagnosticSubsystem(4) upsDiagSubSysSystemPowerSupplyTable(14) upsDiagSubSysSystemPowerSupplyEntry(1) upsDiagSubSysSystemPowerSupplyStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsDiagnostics(13) upsDiagnosticSubsystem(4) upsDiagSubSysSystemPowerSupplyTable(14) upsDiagSubSysSystemPowerSupplyEntry(1) upsDiagSubSysSystemPowerSupplyStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsDiagnostics(13) upsDiagnosticSubsystem(4) upsDiagSubSysSystemPowerSupplyTable(14) upsDiagSubSysSystemPowerSupplyEntry(1) upsDiagSubSysSystemPowerSupplyStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsDiagnostics(13) upsDiagnosticSubsystem(4) upsDiagSubSysSystemPowerSupplyTable(14) upsDiagSubSysSystemPowerSupplyEntry(1) upsDiagSubSysSystemPowerSupplyStatus(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsDiagnostics(13) upsDiagnosticSubsystem(4) upsDiagSubSysSystemPowerSupplyTable(14) upsDiagSubSysSystemPowerSupplyEntry(1) upsDiagSubSysSystemPowerSupplyStatus(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsDiagnostics(13) upsDiagnosticSubsystem(4) upsDiagSubSysSystemPowerSupplyTable(14) upsDiagSubSysSystemPowerSupplyEntry(1) upsDiagSubSysSystemPowerSupplyStatus(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsDiagnostics/upsDiagnosticSubsystem/upsDiagSubSysSystemPowerSupplyTable/upsDiagSubSysSystemPowerSupplyEntry/upsDiagSubSysSystemPowerSupplyStatus
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsDiagnostics/upsDiagnosticSubsystem/upsDiagSubSysSystemPowerSupplyTable/upsDiagSubSysSystemPowerSupplyEntry/upsDiagSubSysSystemPowerSupplyStatus
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ups/upsDiagnostics/upsDiagnosticSubsystem/upsDiagSubSysSystemPowerSupplyTable/upsDiagSubSysSystemPowerSupplyEntry/upsDiagSubSysSystemPowerSupplyStatus
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ups/upsDiagnostics/upsDiagnosticSubsystem/upsDiagSubSysSystemPowerSupplyTable/upsDiagSubSysSystemPowerSupplyEntry/upsDiagSubSysSystemPowerSupplyStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsDiagnostics/upsDiagnosticSubsystem/upsDiagSubSysSystemPowerSupplyTable/upsDiagSubSysSystemPowerSupplyEntry/upsDiagSubSysSystemPowerSupplyStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsDiagnostics/upsDiagnosticSubsystem/upsDiagSubSysSystemPowerSupplyTable/upsDiagSubSysSystemPowerSupplyEntry/upsDiagSubSysSystemPowerSupplyStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/1/13/4/14/1/3

    Description by mibdepot

    The status of the System Power Supply.
    unknown(1) indicates the device status is unknown.
    notInstalled(2) indicates the device is not installed.
    offOk(3) indicates the device status is off and OK.
    onOk(4) indicates the device status is on and OK.
    offFail(5) indicates the device status is off and failed.
    onFail(6) indicates the device status is on and failed.
    lostComm(7) indicates the device has lost communication.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    The status of the System Power Supply.
    unknown(1) indicates the device status is unknown.
    notInstalled(2) indicates the device is not installed.
    offOk(3) indicates the device status is off and OK.
    onOk(4) indicates the device status is on and OK.
    offFail(5) indicates the device status is off and failed.
    onFail(6) indicates the device status is on and failed.
    lostComm(7) indicates the device has lost communication.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    upsDiagSubSysSystemPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), notInstalled (2), offOk (3), onOk (4), offFail (5), onFail (6), lostComm (7) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the System Power Supply. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication." ::= { upsDiagSubSysSystemPowerSupplyEntry 3 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsDiagSubSysSystemPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), notInstalled (2), offOk (3), onOk (4), offFail (5), onFail (6), lostComm (7) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the System Power Supply. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication." ::= { upsDiagSubSysSystemPowerSupplyEntry 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.13.4.14.1.1 upsDiagSubSysSystemPowerSupplyFrameIndex 0 0 The frame index entry.
    1.3.6.1.4.1.318.1.1.1.13.4.14.1.2 upsDiagSubSysSystemPowerSupplyIndex 0 0 The index of a System Power Supply.
    1.3.6.1.4.1.318.1.1.1.13.4.14.1.4 upsDiagSubSysSystemPowerSupplyFirmwareRev 0 0 The firmware revision of the System Power Supply monitor card.
    1.3.6.1.4.1.318.1.1.1.13.4.14.1.5 upsDiagSubSysSystemPowerSupplyHardwareRev 0 0 The hardware revision of the System Power Supply monitor card.
    1.3.6.1.4.1.318.1.1.1.13.4.14.1.6 upsDiagSubSysSystemPowerSupplySerialNum 0 0 The serial number of the System Power Supply monitor card.
    1.3.6.1.4.1.318.1.1.1.13.4.14.1.7 upsDiagSubSysSystemPowerSupplyManufactureDate 0 0 The date of the manufacture for the System Power Supply monitor card.