The status of the Switch Gear Bypass Input Switch.
unknown(1) indicates the switch status is unknown.
notInstalled(2) indicates the switch is not installed.
opened(3) indicates the switch is opened.
closed(4) indicates the switch is closed.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The status of the Switch Gear Bypass Input Switch.
unknown(1) indicates the switch status is unknown.
notInstalled(2) indicates the switch is not installed.
opened(3) indicates the switch is opened.
closed(4) indicates the switch is closed.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
upsDiagSwitchGearBypassInputSwitchStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), notInstalled (2), opened (3), closed (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the Switch Gear Bypass Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed." ::= { upsDiagSwitchGear 5 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
upsDiagSwitchGearBypassInputSwitchStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), notInstalled (2), opened (3), closed (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the Switch Gear Bypass Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed." ::= { upsDiagSwitchGear 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.13.5.1.5.0 | upsDiagSwitchGearBypassInputSwitchStatus | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.13.5.1.1 | upsDiagSwitchGearStatus | 1 | 1 | The status of the Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not ins… |
1.3.6.1.4.1.318.1.1.1.13.5.1.2 | upsDiagSwitchGearInputSwitchStatus | 1 | 1 | The status of the Switch Gear Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the swit… |
1.3.6.1.4.1.318.1.1.1.13.5.1.3 | upsDiagSwitchGearOutputSwitchStatus | 1 | 1 | The status of the Switch Gear Output Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the swi… |
1.3.6.1.4.1.318.1.1.1.13.5.1.4 | upsDiagSwitchGearBypassSwitchStatus | 1 | 1 | The status of the Switch Gear Bypass Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the swi… |
1.3.6.1.4.1.318.1.1.1.13.5.1.6 | upsDiagSwitchGearBreakerTableSize | 1 | 1 | The number of switchgear breakers attached to the UPS. |
1.3.6.1.4.1.318.1.1.1.13.5.1.7 | upsDiagSwitchGearBreakerTable | 1 | 4 | Switchgear breaker table. |
1.3.6.1.4.1.318.1.1.1.13.5.1.8 | upsDiagSubFeedBreakerTableSize | 1 | 1 | The number of subfeed breakers attached to the UPS. |
1.3.6.1.4.1.318.1.1.1.13.5.1.9 | upsDiagSubFeedBreakerTable | 1 | 6 | Subfeed breaker table. |
1.3.6.1.4.1.318.1.1.1.13.5.1.10 | upsDiagSwitchGearInstallationLoadPct | 0 | 0 | The actual output load expressed as a percentage of the rating of the UPS. |