upsParallelSystem OBJECT IDENTIFIER ::= { ups 14 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
upsParallelSystem OBJECT IDENTIFIER ::= { ups 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.14.1 | upsParallelSysLocalAddress | 1 | 1 | Defines the UPS ID number in the parallel system. |
1.3.6.1.4.1.318.1.1.1.14.2 | upsParallelSysRemoteAddress | 1 | 1 | Defines the total number of UPSs in parallel. |
1.3.6.1.4.1.318.1.1.1.14.3 | upsParallelSysRedundancy | 1 | 1 | The redundancy warning level for paralleled UPS nplus0 (1) indicates that there are no redundant units. nplus1 (2) indicates that… |
1.3.6.1.4.1.318.1.1.1.14.4 | upsParallelInputMaximumCurrent | 0 | 0 | Maximum input RMS current of the parallel system measured in Amperes. |
1.3.6.1.4.1.318.1.1.1.14.5 | upsParallelTotalOutputPower | 0 | 0 | The Total Ouptut power of UPS in KW when UPS are configured in parallel or -1 if it's unsupported by this UPS. |
1.3.6.1.4.1.318.1.1.1.14.6 | upsParallelTotalOutputApparentPower | 0 | 0 | The Total Ouptut Apparent power of UPS in kVA when UPS are configured in parallel or -1 if it's unsupported by this UPS. |
1.3.6.1.4.1.318.1.1.1.14.7 | upsParallelInputPhaseTable | 1 | 11 | A list of input table entries. |
1.3.6.1.4.1.318.1.1.1.14.8 | upsParallelOutputPhaseTable | 1 | 7 | A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases. |
1.3.6.1.4.1.318.1.1.1.14.9 | upsParallelOutputApparentPowerTable | 1 | 3 | A list of output table entries. The number of entries is given by the value of upsOutputNumPhases. |
1.3.6.1.4.1.318.1.1.1.14.10 | upsParallelDiagSubSysBreakerTable | 1 | 5 | Allows for diagnostics of parallel Circuit Breakers. |
1.3.6.1.4.1.318.1.1.1.14.11 | upsParallelOutputTotalPercentLoad | 0 | 0 | The percentage of the UPS total load capacity in kVA or -1 if it's unsupported by this UPS. |
1.3.6.1.4.1.318.1.1.1.14.12 | upsParallelOutputActivePowerTable | 1 | 3 | A list of output table entries. The number of entries is given by the value of upsParallelSysRemoteAddress. |
1.3.6.1.4.1.318.1.1.1.14.13 | upsParallelSysSwitchGearInstallationLoadPct | 0 | 0 | The actual output load expressed as a percentage of the rating of the Parallel UPS system. |
1.3.6.1.4.1.318.1.1.1.14.14 | upsParallelSysRedundancyStatus | 0 | 0 | Displays the number of backup or redundant UPSs set up on the parallel system. nplus0 (1) no redundant units. nplus1 (2) one redu… |
1.3.6.1.4.1.318.1.1.1.14.15 | upsParallelSysName | 0 | 0 | An ID string for the group of UPS units in the same parallel system. Some products do not allow write operations for this OID. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.1 | upsIdent | 2 | 16 | None |
1.3.6.1.4.1.318.1.1.1.2 | upsBattery | 3 | 78 | None |
1.3.6.1.4.1.318.1.1.1.3 | upsInput | 3 | 39 | None |
1.3.6.1.4.1.318.1.1.1.4 | upsOutput | 3 | 45 | None |
1.3.6.1.4.1.318.1.1.1.5 | upsConfig | 2 | 104 | None |
1.3.6.1.4.1.318.1.1.1.6 | upsControl | 2 | 22 | None |
1.3.6.1.4.1.318.1.1.1.7 | upsTest | 2 | 20 | None |
1.3.6.1.4.1.318.1.1.1.8 | upsComm | 1 | 2 | None |
1.3.6.1.4.1.318.1.1.1.9 | upsPhase | 3 | 57 | None |
1.3.6.1.4.1.318.1.1.1.10 | upsSyncCtrlGroup | 2 | 20 | None |
1.3.6.1.4.1.318.1.1.1.11 | upsState | 2 | 23 | None |
1.3.6.1.4.1.318.1.1.1.12 | upsOutletGroups | 3 | 38 | None |
1.3.6.1.4.1.318.1.1.1.13 | upsDiagnostics | 6 | 207 | None |
1.3.6.1.4.1.318.1.1.1.15 | upsPhysicalLayout | 9 | 24 | None |
1.3.6.1.4.1.318.1.1.1.16 | upsIntegratedATS | 5 | 15 | None |