Reference record for OID 1.3.6.1.4.1.318.1.1.1.2.3.7



parent
1.3.6.1.4.1.318.1.1.1.2.3 (upsHighPrecBattery)
node code
7
node name
upsHighPrecBatteryActualVoltageTable
dot oid
1.3.6.1.4.1.318.1.1.1.2.3.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsBattery(2) upsHighPrecBattery(3) upsHighPrecBatteryActualVoltageTable(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsBattery(2) upsHighPrecBattery(3) upsHighPrecBatteryActualVoltageTable(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsBattery(2) upsHighPrecBattery(3) upsHighPrecBatteryActualVoltageTable(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsBattery(2) upsHighPrecBattery(3) upsHighPrecBatteryActualVoltageTable(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsBattery(2) upsHighPrecBattery(3) upsHighPrecBatteryActualVoltageTable(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsBattery(2) upsHighPrecBattery(3) upsHighPrecBatteryActualVoltageTable(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsBattery/upsHighPrecBattery/upsHighPrecBatteryActualVoltageTable
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsBattery/upsHighPrecBattery/upsHighPrecBatteryActualVoltageTable
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ups/upsBattery/upsHighPrecBattery/upsHighPrecBatteryActualVoltageTable
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ups/upsBattery/upsHighPrecBattery/upsHighPrecBatteryActualVoltageTable
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsBattery/upsHighPrecBattery/upsHighPrecBatteryActualVoltageTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsBattery/upsHighPrecBattery/upsHighPrecBatteryActualVoltageTable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/1/2/3/7

    Description by mibdepot

    A list of Battery frame table entries. The number of entries
    is given by the number of Battery frames.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    A list of Battery frame table entries. The number of entries
    is given by the number of Battery frames.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    upsHighPrecBatteryActualVoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF UPSHighPrecBatteryActualVoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Battery frame table entries. The number of entries is given by the number of Battery frames." ::= { upsHighPrecBattery 7 }

    Information by oid_info

    Vendor: APC
    Module: PowerNet-MIB (powernet401.mib)
    Type: TABLE
    Access: not-accessible
    Syntax: SEQUENCE OF

    Automatically extracted from www.mibdepot.com

    Information by circitor

    upsHighPrecBatteryActualVoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF UPSHighPrecBatteryActualVoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Battery frame table entries. The number of entries is given by the number of Battery frames." ::= { upsHighPrecBattery 7 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.2.3.7.1 upsHighPrecBatteryActualVoltageEntry 3 3 An entry containing information applicable to a
    particular battery frame.

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.2.3.1 upsHighPrecBatteryCapacity 1 1 The remaining battery capacity expressed in
    tenths of percent of full capacity.
    1.3.6.1.4.1.318.1.1.1.2.3.2 upsHighPrecBatteryTemperature 1 1 The current internal UPS temperature expressed in
    tenths of degrees Celsius.
    1.3.6.1.4.1.318.1.1.1.2.3.3 upsHighPrecBatteryNominalVoltage 1 1 The nominal battery voltage in tenths of Volts.
    1.3.6.1.4.1.318.1.1.1.2.3.4 upsHighPrecBatteryActualVoltage 1 1 The actual battery bus voltage in tenths of Volts.
    1.3.6.1.4.1.318.1.1.1.2.3.5 upsHighPrecBatteryCurrent 1 1 The battery current in tenths of Amps.
    1.3.6.1.4.1.318.1.1.1.2.3.6 upsHighPrecTotalDCCurrent 1 1 The total DC current in tenths of Amps.
    1.3.6.1.4.1.318.1.1.1.2.3.8 upsHighPrecTotalDCCurrentTable 1 4 A list of Battery Frame table entries. The number of entries
    is given by the number of battery frames.
    1.3.6.1.4.1.318.1.1.1.2.3.9 upsHighPrecBatteryCurrentTable 1 5 A list of Battery Frame table entries. The number of entries
    is given by the number of battery frames.