The maximum percentage of the UPS power capacity
in Watts measured at redundancy @ (n + x) presently
being used on this output phase since the last
reset (upsPhaseResetMaxMinValues), or -1 if it's
unsupported by this UPS. Sampled every 30 seconds.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The maximum percentage of the UPS power capacity
in Watts measured at redundancy @ (n + x) presently
being used on this output phase since the last
reset (upsPhaseResetMaxMinValues), or -1 if it's
unsupported by this UPS. Sampled every 30 seconds.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
upsPhaseOutputMaxPercentPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds." ::= { upsPhaseOutputPhaseEntry 17 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
upsPhaseOutputMaxPercentPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds." ::= { upsPhaseOutputPhaseEntry 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.9.3.3.1.1 | upsPhaseOutputPhaseTableIndex | 0 | 0 | The output identifier. |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.2 | upsPhaseOutputPhaseIndex | 0 | 0 | The output phase identifier. |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.3 | upsPhaseOutputVoltage | 0 | 0 | The output voltage in VAC, or -1 if it's unsupported by this UPS. |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.4 | upsPhaseOutputCurrent | 0 | 0 | The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.5 | upsPhaseOutputMaxCurrent | 0 | 0 | The maximum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.6 | upsPhaseOutputMinCurrent | 0 | 0 | The minimum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.7 | upsPhaseOutputLoad | 0 | 0 | The output load in VA, or -1 if it's unsupported by this UPS. |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.8 | upsPhaseOutputMaxLoad | 0 | 0 | The maximum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sa… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.9 | upsPhaseOutputMinLoad | 0 | 0 | The minimum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sa… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.10 | upsPhaseOutputPercentLoad | 0 | 0 | The percentage of the UPS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's un… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.11 | upsPhaseOutputMaxPercentLoad | 0 | 0 | The maximum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase … |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.12 | upsPhaseOutputMinPercentLoad | 0 | 0 | The minimum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase … |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.13 | upsPhaseOutputPower | 0 | 0 | The output power in Watts, or -1 if it's unsupported by this UPS. |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.14 | upsPhaseOutputMaxPower | 0 | 0 | The maximum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UP… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.15 | upsPhaseOutputMinPower | 0 | 0 | The minimum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UP… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.16 | upsPhaseOutputPercentPower | 0 | 0 | The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it'… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.18 | upsPhaseOutputMinPercentPower | 0 | 0 | The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output ph… |
1.3.6.1.4.1.318.1.1.1.9.3.3.1.19 | upsPhaseOutputPowerFactor | 0 | 0 | The Output power factor of the UPS in hundredth. |