The type of valve actuator installed on the Condenser
fluid valve. The Condenser fluid valve controls the
flow of coolant into the heat exchanger (condenser)
to regulate head pressure.
A value of notApplicable indicates that this OID does
not apply to this device due to its configuration.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The type of valve actuator installed on the Condenser
fluid valve. The Condenser fluid valve controls the
flow of coolant into the heat exchanger (condenser)
to regulate head pressure.
A value of notApplicable indicates that this OID does
not apply to this device due to its configuration.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
airFMSysCndsrFluidVlvAct OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), floatingControl (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of valve actuator installed on the Condenser fluid valve. The Condenser fluid valve controls the flow of coolant into the heat exchanger (condenser) to regulate head pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysSetup 13 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
airFMSysCndsrFluidVlvAct OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), floatingControl (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of valve actuator installed on the Condenser fluid valve. The Condenser fluid valve controls the flow of coolant into the heat exchanger (condenser) to regulate head pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysSetup 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.3.13.0 | airFMSysCndsrFluidVlvAct | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.3.1 | airFMSysNumModules | 1 | 1 | The number of Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its c… |
1.3.6.1.4.1.318.1.1.13.1.4.3.2 | airFMSysNumPCIOMs | 1 | 1 | The number of Programmable Customer Input/Output Modules (PCIOMs) installed in the Main Module of this System. Each PCIOM adds fo… |
1.3.6.1.4.1.318.1.1.13.1.4.3.3 | airFMSysMainsVlt | 1 | 1 | The mains voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its… |
1.3.6.1.4.1.318.1.1.13.1.4.3.4 | airFMSysUPSVlt | 1 | 1 | The UPS voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its c… |
1.3.6.1.4.1.318.1.1.13.1.4.3.5 | airFMSysCoilCfg | 1 | 1 | The type of cooling coils installed in the Modules in this System: DX coil, DX and MultiCool (chilled water) coils, DX and Econom… |
1.3.6.1.4.1.318.1.1.13.1.4.3.6 | airFMSysRefrigType | 1 | 1 | The type of refrigerant used by each compressor in the system. A value of notApplicable indicates that this OID does not apply to … |
1.3.6.1.4.1.318.1.1.13.1.4.3.7 | airFMSysHeatRejection | 1 | 1 | The method the Modules in this System use to transfer heat away from the refrigerant. A value of notApplicable indicates that thi… |
1.3.6.1.4.1.318.1.1.13.1.4.3.8 | airFMSysDischAirPtrn | 1 | 1 | The discharge air pattern for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this … |
1.3.6.1.4.1.318.1.1.13.1.4.3.9 | airFMSysAirFltr | 1 | 1 | The type of air filters (standard or high efficiency) installed in the Modules of this System. A value of notApplicable indicates… |
1.3.6.1.4.1.318.1.1.13.1.4.3.10 | airFMSysFlowSwitch | 1 | 1 | The location of the optional flow switch. None: No flow switch is installed in this System. DX: Coolant input to the heat exchang… |
1.3.6.1.4.1.318.1.1.13.1.4.3.11 | airFMSysCoilFluidVlvAct | 1 | 1 | The type of valve actuator installed on the coil fluid valve. The coil fluid valve controls the flow of coolant into a fluid cool… |
1.3.6.1.4.1.318.1.1.13.1.4.3.12 | airFMSysCoilFluidVlvType | 1 | 1 | The type of coil fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not a… |
1.3.6.1.4.1.318.1.1.13.1.4.3.14 | airFMSysCndsrFluidVlvType | 1 | 1 | The type of Condenser fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does… |
1.3.6.1.4.1.318.1.1.13.1.4.3.15 | airFMSysHotWaterVlvAct | 1 | 1 | The type of valve actuator installed on the hot water valve. A value of notApplicable indicates that this OID does not apply to th… |
1.3.6.1.4.1.318.1.1.13.1.4.3.16 | airFMSysNumRemoteSensors | 1 | 1 | The number of remote sensors detected by the system. |