The low temperature threshold for coolant at the
inlet to the fluid coil. If the fluid coil coolant
temperature drops below the threshold, an alarm will
occur. Measured in tenths of degrees Celsius.
A value of -2147483648 indicates that this OID does
not apply to this device due to its configuration.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The low temperature threshold for coolant at the
inlet to the fluid coil. If the fluid coil coolant
temperature drops below the threshold, an alarm will
occur. Measured in tenths of degrees Celsius.
A value of -2147483648 indicates that this OID does
not apply to this device due to its configuration.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
airFMSysLowCoilFluidTempC OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysThresholds 7 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
airFMSysLowCoilFluidTempC OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysThresholds 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.9.7.0 | airFMSysLowCoilFluidTempC | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.9.1 | airFMSysHighSplyTempC | 1 | 1 | The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm wi… |
1.3.6.1.4.1.318.1.1.13.1.4.9.2 | airFMSysHighSplyTempF | 1 | 1 | The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm wi… |
1.3.6.1.4.1.318.1.1.13.1.4.9.3 | airFMSysLowSplyTempC | 1 | 1 | The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm… |
1.3.6.1.4.1.318.1.1.13.1.4.9.4 | airFMSysLowSplyTempF | 1 | 1 | The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm… |
1.3.6.1.4.1.318.1.1.13.1.4.9.5 | airFMSysHighCoilFluidTempC | 1 | 1 | The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the thre… |
1.3.6.1.4.1.318.1.1.13.1.4.9.6 | airFMSysHighCoilFluidTempF | 1 | 1 | The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the thre… |
1.3.6.1.4.1.318.1.1.13.1.4.9.8 | airFMSysLowCoilFluidTempF | 1 | 1 | The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the t… |
1.3.6.1.4.1.318.1.1.13.1.4.9.9 | airFMSysHighCtrlTempC | 1 | 1 | The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. M… |
1.3.6.1.4.1.318.1.1.13.1.4.9.10 | airFMSysHighCtrlTempF | 1 | 1 | The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. M… |
1.3.6.1.4.1.318.1.1.13.1.4.9.11 | airFMSysLowCtrlTempC | 1 | 1 | The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur.… |
1.3.6.1.4.1.318.1.1.13.1.4.9.12 | airFMSysLowCtrlTempF | 1 | 1 | The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur.… |
1.3.6.1.4.1.318.1.1.13.1.4.9.13 | airFMSysHighCtrlHum | 1 | 1 | The high humidity threshold for air monitored by the System. If the humidity exceeds the threshold, an alarm will occur. Measure… |
1.3.6.1.4.1.318.1.1.13.1.4.9.14 | airFMSysLowCtrlHum | 1 | 1 | The low humidity threshold for air monitored by the System. If the humidity drops below the threshold, an alarm will occur. Meas… |
1.3.6.1.4.1.318.1.1.13.1.4.9.15 | airFMSysTempAlarmDelay | 1 | 1 | The amount of time the blower must be on before a temperature alarm can be issued. Measured in seconds. A value of -2147483648 in… |
1.3.6.1.4.1.318.1.1.13.1.4.9.16 | airFMSysHumAlarmDelay | 1 | 1 | The amount of time the blower must be on before a humidity alarm can be issued. Measured in seconds. A value of -2147483648 indi… |