The RDU configuration table entry.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The RDU configuration table entry.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
airIRG3RDUConfigEntry OBJECT-TYPE SYNTAX AirIRG3RDUConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The RDU configuration table entry." INDEX { airIRG3RDUConfigDeviceIndex} ::= { airIRG3RDUConfigTable 1 }
Vendor: APC
Module: PowerNet-MIB (powernet401.mib)
Type: ENTRY
Access: not-accessible
Syntax: AirIRG3RDUConfigEntry
Automatically extracted from www.mibdepot.com
airIRG3RDUConfigEntry OBJECT-TYPE SYNTAX AirIRG3RDUConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The RDU configuration table entry." INDEX { airIRG3RDUConfigDeviceIndex} ::= { airIRG3RDUConfigTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.6.4.7.1.1 | airIRG3RDUConfigDeviceIndex | 0 | 0 | Index of RDU configuration table. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.2 | airIRG3RDUConfigRDUID | 0 | 0 | The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.3 | airIRG3RDUConfigStopOnLeakDetect | 0 | 0 | The RDU stop on leak detect set. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.4 | airIRG3RDUConfigStartupDelay | 0 | 0 | The RDU start up delay in seconds. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.5 | airIRG3RDUConfigPumpChangeOverInterval | 0 | 0 | The RDU pump change over interval in days. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.6 | airIRG3RDUConfigPowerSource | 0 | 0 | The RDU power source. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.7 | airIRG3RDUConfigOutputSource | 0 | 0 | The RDU output source. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.8 | airIRG3RDUConfigInputNormalState | 0 | 0 | The RDU Input Normal State. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.9 | airIRG3RDUConfigOutputNormalState | 0 | 0 | The RDU Output Normal State. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.10 | airIRG3RDUConfigByPassValveEnabled | 0 | 0 | The RDU By Pass Valve Enabled State. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.11 | airIRG3RDUConfigRefrigerantLeakDetectorEnabled | 0 | 0 | The RDU Refrigerant Leak Detector Enabled State. |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.12 | airIRG3RDUConfigCalibrateRefrigerantLeakDetector | 0 | 0 | This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only. The read returns -1. Only 'yes' is suppo… |
1.3.6.1.4.1.318.1.1.13.6.4.7.1.13 | airIRG3RDUConfigOnReadyStandby | 0 | 0 | This parameter allows to configure RDU on/standby parameter. Ready is currently not supported. If unsupported returns -1. |