battManSystemStatus OBJECT IDENTIFIER ::= { battMan 8 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
battManSystemStatus OBJECT IDENTIFIER ::= { battMan 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.16.8.1 | battManSystemAmbientTempC | 1 | 1 | The system ambient temperature in tenths of degrees Celsius. |
1.3.6.1.4.1.318.1.1.16.8.2 | battManSystemAmbientTempF | 1 | 1 | The system ambient temperature in tenths of degrees Fahrenheit. |
1.3.6.1.4.1.318.1.1.16.8.3 | battManSystemPilotTempC | 1 | 1 | The system pilot temperature in tenths of degrees Celsius. |
1.3.6.1.4.1.318.1.1.16.8.4 | battManSystemPilotTempF | 1 | 1 | The system pilot temperature in tenths of degrees Fahrenheit. |
1.3.6.1.4.1.318.1.1.16.8.5 | battManSystemAmbientHighTempAlarm | 1 | 1 | battManSystemAmbientHightempAlarm |
1.3.6.1.4.1.318.1.1.16.8.6 | battManSystemAmbientLowTempAlarm | 1 | 1 | When set to alarm(2), indicates that the system has a low temperature alarm. |
1.3.6.1.4.1.318.1.1.16.8.7 | battManSystemPilotBatteryHighTempAlarm | 1 | 1 | battManSystemPilotBatteryHightempAlarm |
1.3.6.1.4.1.318.1.1.16.8.8 | battManSystemPilotProbeDisconnected | 1 | 1 | When set to alarm(2), indicates that the system pilot probe is disconnected. |
1.3.6.1.4.1.318.1.1.16.8.9 | battManSystemAmbientProbeDisconnected | 1 | 1 | When set to alarm(2), indicates that the system ambient probe is disconnected. |
1.3.6.1.4.1.318.1.1.16.8.10 | battManSystemConfigurationInvalid | 1 | 1 | When set to alarm(2), indicates that the system is not configured correctly. |
1.3.6.1.4.1.318.1.1.16.8.11 | battManSystemSuspendVoltage | 1 | 1 | When set to alarm(2), indicates that the system has suspended voltage scans. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.16.1 | battManIdent | 6 | 12 | None |
1.3.6.1.4.1.318.1.1.16.2 | battManSystemCalib | 1 | 2 | None |
1.3.6.1.4.1.318.1.1.16.3 | battManUnitCalib | 2 | 8 | None |
1.3.6.1.4.1.318.1.1.16.4 | battManStringCalib | 2 | 8 | None |
1.3.6.1.4.1.318.1.1.16.5 | battManBatteryCalib | 4 | 12 | None |
1.3.6.1.4.1.318.1.1.16.6 | battManConfig | 22 | 44 | None |
1.3.6.1.4.1.318.1.1.16.7 | battManAlarm | 4 | 8 | None |
1.3.6.1.4.1.318.1.1.16.9 | battManStringStatus | 2 | 17 | None |
1.3.6.1.4.1.318.1.1.16.10 | battManBatteryStatus | 4 | 36 | None |
1.3.6.1.4.1.318.1.1.16.11 | battManInputContactStatus | 2 | 10 | None |
1.3.6.1.4.1.318.1.1.16.12 | battManControl | 4 | 8 | None |
1.3.6.1.4.1.318.1.1.16.13 | battManTestResults | 10 | 28 | None |
1.3.6.1.4.1.318.1.1.16.14 | battManUnitStatus | 2 | 10 | None |