Rectifier Communication Fail timeout. This OID represents the time interval in which there is no
communication between the rectifier and the master controller at which the rectifier will reset
all its values to default.
Values are represented in hundredths of Seconds.
Attempts to set the value above or below the acceptable range of the powerplant
will cause the value to be set at the high or low point of the range respectively.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Rectifier Communication Fail timeout. This OID represents the time interval in which there is no
communication between the rectifier and the master controller at which the rectifier will reset
all its values to default.
Values are represented in hundredths of Seconds.
Attempts to set the value above or below the acceptable range of the powerplant
will cause the value to be set at the high or low point of the range respectively.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
dm3ConfigRectFailComm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Rectifier Communication Fail timeout. This OID represents the time interval in which there is no communication between the rectifier and the master controller at which the rectifier will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively." ::= { dm3ConfigRectThresh 4 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
dm3ConfigRectFailComm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Rectifier Communication Fail timeout. This OID represents the time interval in which there is no communication between the rectifier and the master controller at which the rectifier will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively." ::= { dm3ConfigRectThresh 4 }
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.4.0 | dm3ConfigRectFailComm | 0 | 0 | None |
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.1 | dm3ConfigRectHighVoltThresh | 1 | 1 | Rectifier high voltage threshold. If rectifier voltage exceeds threshold a rectifier high voltage alarm will occur. Values are … |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.2 | dm3ConfigRectLowVoltThresh | 1 | 1 | Rectifier low voltage threshold. If rectifier voltage is under threshold a rectifier low voltage alarm will occur. Values are r… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.3 | dm3ConfigRectFailSafe | 1 | 1 | Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers to use in the event of communications lo… |