dm3ConfigConvAlarms OBJECT IDENTIFIER ::= { dm3ConfigConverter 2 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
dm3ConfigConvAlarms OBJECT IDENTIFIER ::= { dm3ConfigConverter 2 }
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.1 | dm3ConfigConvHighVoltAlarm | 1 | 1 | For the Converter High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting t… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.2 | dm3ConfigConvLowVoltAlarm | 1 | 1 | For the Converter Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting th… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.3 | dm3ConfigConvConfigAlarm | 1 | 1 | For the Converter Configuration Alarm (indicating a new converter has been detected); Setting this OID to alarmIgnore (1) result… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.4 | dm3ConfigConv1ofNAlarm | 1 | 1 | For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed); Setting this OID to alarmIgnore (1… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.5 | dm3ConfigConv2ofNAlarm | 1 | 1 | For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed); Setting this OID to alarm… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.6 | dm3ConfigConvDiagAlarm | 1 | 1 | For the Converter Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting th… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.7 | dm3ConfigConvImbalanceAlarm | 1 | 1 | For the Converter Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.8 | dm3ConfigConvCurrLimitAlarm | 1 | 1 | For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state); Setting this OID to alarmIgnore … |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.9 | dm3ConfigConvStandbyAlarm | 1 | 1 | For the Converter Standby Alarm (indicating the converter is in the Standby state); Setting this OID to alarmIgnore (1) results … |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.10 | dm3ConfigConvFanFailAlarm | 1 | 1 | For the Converter Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this … |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.11 | dm3ConfigConvFailAlarm | 1 | 1 | For the Converter Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID … |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.12 | dm3ConfigConvHwVoltAlarm | 1 | 1 | For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID … |
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1 | dm3ConfigConvThresh | 7 | 14 | None |