This object is the identifier of a Inter-
face on a managed device. If there is an ifEn-
try that is directly associated with this it
should have the same value as ifIndex. Otherwise,
the value exceeds ifNumber, and is a unique
identifier following this rule: inside interfaces (e.g.,
equipment side) with even numbers and outside
interfaces (e.g., network side) with odd
numbers.
Parsed from file ncmimux.mib.txt
Company: None
Module: VERILINK-ENTERPRISE-NCMIMUX-MIB
This object is the identifier of a Inter-
face on a managed device. If there is an ifEn-
try that is directly associated with this it
should have the same value as ifIndex. Otherwise,
the value exceeds ifNumber, and is a unique
identifier following this rule: inside interfaces (e.g.,
equipment side) with even numbers and outside
interfaces (e.g., network side) with odd
numbers.
Parsed from file VERILINK-ENTERPRISE-NCMIMUX-MIB.mib
Module: VERILINK-ENTERPRISE-NCMIMUX-MIB
Vendor: Verilink Corp
Module: VERILINK-ENTERPRISE-NCMIMUX-MIB
[Automatically extracted from oidview.com]
ncmimuxDTEStatIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of a Inter- face on a managed device. If there is an ifEn- try that is directly associated with this it should have the same value as ifIndex. Otherwise, the value exceeds ifNumber, and is a unique identifier following this rule: inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers." ::= { ncmimuxDTEStatEntry 2 }
ncmimuxDTEStatIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of a Inter- face on a managed device. If there is an ifEn- try that is directly associated with this it should have the same value as ifIndex. Otherwise, the value exceeds ifNumber, and is a unique identifier following this rule: inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers." ::= { ncmimuxDTEStatEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.321.1.3030.7003.1.1 | ncmimuxNIDDTEStatIndex | 0 | 0 | This variable indicates the node id value of the node. |
1.3.6.1.4.1.321.1.3030.7003.1.3 | ncmimuxDTEStatReg | 0 | 0 | This object reports the contents of the DTE Status Register as read from the IMUX hardware. |
1.3.6.1.4.1.321.1.3030.7003.1.4 | ncmimuxDTEStatLPBK | 0 | 0 | This object reports the DTE Pattern and Loopback Code Register Status. (0) indicates that a Loop Up Code was detected. (1) indiā¦ |
1.3.6.1.4.1.321.1.3030.7003.1.5 | ncmimuxDTEStatAlarm | 0 | 0 | This object reports the front panel alarm LED status for the DTE interface. |