Performance Control Enabled/Disabled for M13.
Parsed from file ncmm13.mib.txt
Company: None
Module: VERILINK-ENTERPRISE-NCMM13-MIB
Performance Control Enabled/Disabled for M13.
Parsed from file VERILINK-ENTERPRISE-NCMM13-MIB.mib
Module: VERILINK-ENTERPRISE-NCMM13-MIB
Vendor: Verilink Corp
Module: VERILINK-ENTERPRISE-NCMM13-MIB
[Automatically extracted from oidview.com]
ncmm13DS3PerfControl OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Performance Control Enabled/Disabled for M13." ::= { ncmm13DS3PortEntry 5 }
ncmm13DS3PerfControl OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Performance Control Enabled/Disabled for M13." ::= { ncmm13DS3PortEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.321.1.3037.14000.1.1 | ncmm13DS3PortNIDIndex | 0 | 0 | This variable indicates the node id value of the node. |
1.3.6.1.4.1.321.1.3037.14000.1.2 | ncmm13DS3PortIndex | 0 | 0 | The index value which uniquely identifies the DS3 interface to which this entry is applica- ble. The interface identified by … |
1.3.6.1.4.1.321.1.3037.14000.1.3 | ncmm13DS3ModeControl | 0 | 0 | The Mode Control Bit for M13. |
1.3.6.1.4.1.321.1.3037.14000.1.4 | ncmm13DS3LineType | 0 | 0 | The Line Type for M13. |
1.3.6.1.4.1.321.1.3037.14000.1.6 | ncmm13DS3AlarmControl | 0 | 0 | Alarm Control Enabled/Disabled for M13. |
1.3.6.1.4.1.321.1.3037.14000.1.7 | ncmm13DS3FarEndControl | 0 | 0 | Far End Control Enabled/Disabled for M13. |
1.3.6.1.4.1.321.1.3037.14000.1.8 | ncmm13DS3BusType | 0 | 0 | Inband Control Enabled/Disabled for M13. |
1.3.6.1.4.1.321.1.3037.14000.1.9 | ncmm13DS3InbandControl | 0 | 0 | Inband Control Enabled/Disabled for M13. |
1.3.6.1.4.1.321.1.3037.14000.1.10 | ncmm13DS3CableLength | 0 | 0 | Cable length for M13. |
1.3.6.1.4.1.321.1.3037.14000.1.11 | ncmm13DS3EquipCode | 0 | 0 | This is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Ident… |
1.3.6.1.4.1.321.1.3037.14000.1.12 | ncmm13DS3LocationIDCode | 0 | 0 | This is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Pa… |
1.3.6.1.4.1.321.1.3037.14000.1.13 | ncmm13DS3FrameIDCode | 0 | 0 | This is the Far End Frame Identification code that identifies where the equipment is located within a building at a given locatio… |
1.3.6.1.4.1.321.1.3037.14000.1.14 | ncmm13DS3UnitCode | 0 | 0 | This is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message. |
1.3.6.1.4.1.321.1.3037.14000.1.15 | ncmm13DS3FacilityIDCode | 0 | 0 | This code identifies a specific Far End DS3 path. It is sent within the Path Identification Message. |
1.3.6.1.4.1.321.1.3037.14000.1.16 | ncmm13DS3PortIdCode | 0 | 0 | Port ID. |
1.3.6.1.4.1.321.1.3037.14000.1.17 | ncmm13DS3GenIDCode | 0 | 0 | Test Signal Generator ID. |