A table entry containing FRAM netmod specific config information
Parsed from file fore-fram.mib.txt
Company: None
Module: Fore-Framnetmod-MIB
A table entry containing FRAM netmod specific config information
Parsed from file Fore-Framnetmod-MIB.mib
Module: Fore-Framnetmod-MIB
Vendor: Fore Systems, Inc.
Module: Fore-Framnetmod-MIB
[Automatically extracted from oidview.com]
nmFramNetmodConfEntry OBJECT-TYPE SYNTAX NmFramNetmodConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table entry containing FRAM netmod specific config information" INDEX {nmFramBoard, nmFramModule } ::= { nmFramNetmodConfTable 1 }
nmFramNetmodConfEntry OBJECT-TYPE SYNTAX NmFramNetmodConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table entry containing FRAM netmod specific config information" INDEX {nmFramBoard, nmFramModule } ::= { nmFramNetmodConfTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.1.16.3.1.1.1 | nmFramBoard | 0 | 0 | the index of this board within the ATM switch, equivalent to moduleBoard of moduleTable defined in fore-switch.mib |
1.3.6.1.4.1.326.1.16.3.1.1.2 | nmFramModule | 0 | 0 | the number of this network module within the ATM switch board, equivalent to moduleNumber of moduleTable defined in fore-switch.… |
1.3.6.1.4.1.326.1.16.3.1.1.3 | nmFramEpdPpdBufferProportion | 0 | 0 | Configuration of the buffer size configuration for the high and low priority cell. The sum of high and low priority b… |
1.3.6.1.4.1.326.1.16.3.1.1.4 | nmFramEpdclp1HighPrio | 0 | 0 | The threshold for the high priority buffer for EPD and CLP=1 in percentage of the available size |
1.3.6.1.4.1.326.1.16.3.1.1.5 | nmFramEpdclp0HighPrio | 0 | 0 | The threshold for the high priority buffer for EPD and CLP=0 in percentage of the available size |
1.3.6.1.4.1.326.1.16.3.1.1.6 | nmFramPpdclp1HighPrio | 0 | 0 | The threshold for the high priority buffer for PPD and CLP=1, in percentage of the available size |
1.3.6.1.4.1.326.1.16.3.1.1.7 | nmFramEpdclp1LowPrio | 0 | 0 | The threshold for the Low priority buffer for EPD and CLP=1 in percentage of the available size |
1.3.6.1.4.1.326.1.16.3.1.1.8 | nmFramEpdclp0LowPrio | 0 | 0 | The threshold for the Low priority buffer for EPD and CLP=0 in percentage of the available size |
1.3.6.1.4.1.326.1.16.3.1.1.9 | nmFramPpdclp1LowPrio | 0 | 0 | The threshold for the Low priority buffer for ppd and CLP=1 in percentage of the available size |
1.3.6.1.4.1.326.1.16.3.1.1.10 | nmFramOamF5Supervision | 0 | 0 | enable/disable the FR/ATM interworking OAM F5 function on FRAM netmod |
1.3.6.1.4.1.326.1.16.3.1.1.11 | nmFramOamF5AISRxPeriod | 0 | 0 | Time interval at which an AIS OAM cells is to be received, value is a measurement in seconds |
1.3.6.1.4.1.326.1.16.3.1.1.12 | nmFramOamF5AISTxPeriod | 0 | 0 | Time interval at which an AIS OAM cells is to be transmitted, value is a measurement in seconds |
1.3.6.1.4.1.326.1.16.3.1.1.13 | nmFramOamF5RDIRxPeriod | 0 | 0 | Time interval at which an RDI OAM cells is to be received, value is a measurement in seconds |
1.3.6.1.4.1.326.1.16.3.1.1.14 | nmFramOamF5RDITxPeriod | 0 | 0 | Time interval at which an RDI OAM cells is to be transmitted, value is a measurement in seconds |
1.3.6.1.4.1.326.1.16.3.1.1.15 | nmFramOperState | 0 | 0 | This is the operational state corresponding to the FRAM netmod startup state machine. |
1.3.6.1.4.1.326.1.16.3.1.1.16 | nmFramApplSwRelease | 0 | 0 | The Embedded Software Version number running on this netmod |
1.3.6.1.4.1.326.1.16.3.1.1.17 | nmFramBootSwRelease | 0 | 0 | The Boot Software Version number running on this netmod |
1.3.6.1.4.1.326.1.16.3.1.1.18 | nmFramApplKey | 0 | 0 | This object is for the purpose of setting up the Application type for the FRAM netmod. The application key should be specified wh… |
1.3.6.1.4.1.326.1.16.3.1.1.19 | nmFramApplication | 0 | 0 | This object is for the purpose of setting up the Application type for the FRAM netmod. Changing the application type will cause t… |
1.3.6.1.4.1.326.1.16.3.1.1.20 | nmFramOosLED | 0 | 0 | Indicates the netmod service status. This LED is normally dark. When it becomes red, the netmod is Out Of Service (OOS) and can b… |
1.3.6.1.4.1.326.1.16.3.1.1.21 | nmFramMaxSigPathsPerPort | 0 | 0 | This object specifies the max number of UNI instances per port which can be created for FUNI SVC Signaling Support. In other word… |
1.3.6.1.4.1.326.1.16.3.1.1.22 | nmFramStatsMonitor | 0 | 0 | This object specifies whether statistics are to be counted by the netmod system. The object controls from an overall perspective… |
1.3.6.1.4.1.326.1.16.3.1.1.23 | nmFramStatsEnabledTimeStamp | 0 | 0 | nmFramStatsEnabledTimeStamp reflects the time, with reference to sysUpTime, when nmFramStatsMonitor is set to enabled. This will… |
1.3.6.1.4.1.326.1.16.3.1.1.24 | nmFramMsgType | 0 | 0 | This object is the identifier number of the messages that are sent from The SCP to the FRAM netmods. |
1.3.6.1.4.1.326.1.16.3.1.1.25 | nmFramNakCause | 0 | 0 | This object is the error code that indicates why a message sent from the SCP to the FRAM netmod did not succeed. |