This object specifies whether statistics are to be counted at
a service level, this includes service and connection statistics.
When the state changes from enabled to disabled all the related
statistics will be frozen at their current value. When the state
changes from disabled to enabled then all related statistics will
be reset (zeroised). Note that this Monitor is overriden by the
netmod level nmFramStatsMonitor. Refer to fore-fram.mib for more
details.
Parsed from file fore-funi.mib.txt
Company: None
Module: Fore-Funi-MIB
This object specifies whether statistics are to be counted at
a service level, this includes service and connection statistics.
When the state changes from enabled to disabled all the related
statistics will be frozen at their current value. When the state
changes from disabled to enabled then all related statistics will
be reset (zeroised). Note that this Monitor is overriden by the
netmod level nmFramStatsMonitor. Refer to fore-fram.mib for more
details.
Parsed from file Fore-Funi-MIB.mib
Module: Fore-Funi-MIB
Vendor: Fore Systems, Inc.
Module: Fore-Funi-MIB
[Automatically extracted from oidview.com]
funiIfExtStatsMonitor OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether statistics are to be counted at a service level, this includes service and connection statistics. When the state changes from enabled to disabled all the related statistics will be frozen at their current value. When the state changes from disabled to enabled then all related statistics will be reset (zeroised). Note that this Monitor is overriden by the netmod level nmFramStatsMonitor. Refer to fore-fram.mib for more details. " DEFVAL {disabled } ::= { funiIfExtEntry 3 }
funiIfExtStatsMonitor OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether statistics are to be counted at a service level, this includes service and connection statistics. When the state changes from enabled to disabled all the related statistics will be frozen at their current value. When the state changes from disabled to enabled then all related statistics will be reset (zeroised). Note that this Monitor is overriden by the netmod level nmFramStatsMonitor. Refer to fore-fram.mib for more details. " DEFVAL {disabled } ::= { funiIfExtEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.1.16.6.2.1.1 | funiIfExtProfileFuniIndex | 0 | 0 | This is index of the FUNI profile this service is supposed to be using. This index should be used as a key in profileFuniTable |
1.3.6.1.4.1.326.1.16.6.2.1.2 | funiIfExtProfileServiceIndex | 0 | 0 | This is index of the Generic Service profile this service is supposed to be using. This index should be used as a key in profileG… |
1.3.6.1.4.1.326.1.16.6.2.1.4 | funiIfExtNeighborIpAddress | 0 | 0 | The IP address of the neighbor system connected to the far end of this interface, to which a Network Management Station can send… |
1.3.6.1.4.1.326.1.16.6.2.1.5 | funiIfExtStatsEnabledTimeStamp | 0 | 0 | This object reflects the point in time, with reference to sysUpTime, either when funIfExtStatsMonitor is set to enabled or when n… |
1.3.6.1.4.1.326.1.16.6.2.1.6 | funiIfExtSigStatus | 0 | 0 | This object indicates whether there exists a FUNI signalling instance associated with the FUNI service. The possible value for t… |