frPVCConnectIndexValue OBJECT-TYPE
SYNTAX INTEGER ( 0..2147483647 )
MAX-ACCESS read-only
DESCRIPTION
"This object contains an appropriate value to be used for frPVCConnectIndex when creating entries in the frPVCConnectTable. The value 0 indicates that no unassigned entries are available. To obtain the frPVCConnectIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of
this object. After each retrieval, the agent should modify the value to the next unassigned index."
View at oid-info.com
This object contains an appropriate value to be
used for frPVCConnectIndex when creating entries
in the frPVCConnectTable. The value 0 indicates
that no unassigned entries are available. To
obtain the frPVCConnectIndex value for a new
entry, the manager issues a management protocol
retrieval operation to obtain the current value of
this object. After each retrieval, the agent
should modify the value to the next unassigned
index.
Parsed from file rfc1604-internal.mib.txt
Company: marconi
Module: FORE-FRNETSERV-INTERNAL-MIB
frPVCConnectIndexValue OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for frPVCConnectIndex when creating entries in the frPVCConnectTable. The value 0 indicates that no unassigned entries are available. To obtain the frPVCConnectIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index." ::= { intFrnetservObjects 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.1.16.97.1.4.0 | frPVCConnectIndexValue | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.1.16.97.1.1 | intfrLportTable | 1 | 8 | The Frame Relay Logical Port Information table. |
1.3.6.1.4.1.326.1.16.97.1.2 | intfrMgtVCSigTable | 1 | 17 | The Frame Relay Management VC Signaling Parameters and Errors table. |
1.3.6.1.4.1.326.1.16.97.1.3 | intfrPVCEndptTable | 1 | 21 | The Frame Relay PVC End-Point table. This table is used to model a PVC end-point. This table contains the traffic parameters an… |
1.3.6.1.4.1.326.1.16.97.1.5 | intfrPVCConnectTable | 1 | 12 | The Frame Relay PVC Connect table. A bi- directional PVC segment is modeled as one entry in this table. |
1.3.6.1.4.1.326.1.16.97.1.6 | intfrAccountPVCTable | 1 | 5 | The Frame Relay Accounting PVC table. This table is used to perform accounting on a PVC segment end-point basis. |
1.3.6.1.4.1.326.1.16.97.1.7 | intfrAccountLportTable | 1 | 4 | The Frame Relay Accounting Logical Port table. This table is used to perform accounting on a UNI/NNI Logical Port basis. |