Reference record for OID 1.3.6.1.4.1.326.1.16.98.1.1.2
- parent
- 1.3.6.1.4.1.326.1.16.98.1.1 (intfrDlcmiEntry)
- node code
- 2
- node name
- frDlcmiState
- dot oid
- 1.3.6.1.4.1.326.1.16.98.1.1.2
- type
- OBJECT-TYPE
- asn1 oid
-
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fore(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) marconi(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- ...skipped...
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) fore(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) marconi(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) fore(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) marconi(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- ...skipped...
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) fore(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) marconi(326) admin(1) frameInternetworking(16) foreFrameRelayDTE-internal(98) intfrDlcmiTable(1) intfrDlcmiEntry(1) frDlcmiState(2)}
- iri oid
-
- /iso/identified-organization/dod/internet/private/enterprise/fore/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- /iso/identified-organization/dod/internet/private/enterprise/marconi/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- ...skipped...
- /iso/org/dod/internet/private/enterprise/fore/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- /iso/org/dod/internet/private/enterprise/marconi/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- /iso/org/dod/internet/private/enterprises/fore/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- /iso/org/dod/internet/private/enterprises/marconi/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- ...skipped...
- /iso/iso-identified-organization/dod/internet/private/enterprises/fore/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- /iso/iso-identified-organization/dod/internet/private/enterprises/marconi/admin/frameInternetworking/foreFrameRelayDTE-internal/intfrDlcmiTable/intfrDlcmiEntry/frDlcmiState
- iri by oid_info
- /ISO/Identified-Organization/6/1/4/1/326/1/16/98/1/1/2
Description by mibdepot
This variable states which Data Link Connection
Management scheme is active (and by implication, what
DLCI it uses) on the Frame Relay interface.
Parsed from file frame-relay-dte-internal.mib.txt
Company: marconi
Module: FRAME-RELAY-DTE-INTERNAL-MIB
Information by oid_info
Vendor: Marconi
Module: FRAME-RELAY-DTE-INTERNAL-MIB (frame-relay-dte-internal.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
Information by mibdepot
frDlcmiState OBJECT-TYPE
SYNTAX INTEGER {
noLmiConfigured (1),
lmiRev1 (2),
ansiT1617D (3),
ansiT1617B (4),
itut933A (5),
ansiT1617D1994 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable states which Data Link Connection
Management scheme is active (and by implication, what
DLCI it uses) on the Frame Relay interface."
REFERENCE
"American National Standard T1.617-1991, American
National Standard T1.617a-1994, ITU-T Recommendation
Q.933 (03/93)."
::= { intfrDlcmiEntry 2 }
First Registration Authority (recovered by parent 1.3.6.1.4.1.326)
Cooper Eric
Brothers (9)
OID | Name | Sub children | Sub Nodes Total | Description |
1.3.6.1.4.1.326.1.16.98.1.1.1 |
frDlcmiIfIndex |
0 |
0 |
The ifIndex value of the corresponding ifEntry. |
1.3.6.1.4.1.326.1.16.98.1.1.3 |
frDlcmiAddress |
0 |
0 |
This variable states which address format is in use on the Frame Relay interface. |
1.3.6.1.4.1.326.1.16.98.1.1.4 |
frDlcmiAddressLen |
0 |
0 |
This variable states the address length in octets. In the case of Q922 format, the length indicates the entire length of the add… |
1.3.6.1.4.1.326.1.16.98.1.1.5 |
frDlcmiPollingInterval |
0 |
0 |
This is the number of seconds between successive status enquiry messages. |
1.3.6.1.4.1.326.1.16.98.1.1.6 |
frDlcmiFullEnquiryInterval |
0 |
0 |
Number of status enquiry intervals that pass before issuance of a full status enquiry message. |
1.3.6.1.4.1.326.1.16.98.1.1.7 |
frDlcmiErrorThreshold |
0 |
0 |
This is the maximum number of unanswered Status Enquiries the equipment shall accept before declaring the interface down. |
1.3.6.1.4.1.326.1.16.98.1.1.8 |
frDlcmiMonitoredEvents |
0 |
0 |
This is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvent… |
1.3.6.1.4.1.326.1.16.98.1.1.9 |
frDlcmiMaxSupportedVCs |
0 |
0 |
The maximum number of Virtual Circuits allowed for this interface. Usually dictated by the Frame Relay network.
In response to a … |
1.3.6.1.4.1.326.1.16.98.1.1.10 |
frDlcmiMulticast |
0 |
0 |
This indicates whether the Frame Relay interface is using a multicast service. |