This variable indicates the ATM Status of the interface.
The variable is a bit map represented as a sum, therefore
it can represent multiple defects simultaneously. The
sonetAtmNoDefect should be set if and only if no other flag
is set.
The various bit mask values are:
1 sonetAtmNoDefect
2 sonetAtmLCD Loss of Cell Delineation was detected.
LCD is declared when a 'normal pointer
value' is not found for eight
consecutive frames.
4 sonetAtmPlcpLOF Valid PLCP frames were not detected at
the interface.
8 sonetAtmPlcpYellow Plcp Yellow alarm was detected in the
incoming PLCP frame stream.
Parsed from file fore-tc.mib.txt
Company: None
Module: Fore-TC-MIB
This variable indicates the ATM Status of the interface.
The variable is a bit map represented as a sum, therefore
it can represent multiple defects simultaneously. The
sonetAtmNoDefect should be set if and only if no other flag
is set.
The various bit mask values are:
1 sonetAtmNoDefect
2 sonetAtmLCD Loss of Cell Delineation was detected.
LCD is declared when a 'normal pointer
value' is not found for eight
consecutive frames.
4 sonetAtmPlcpLOF Valid PLCP frames were not detected at
the interface.
8 sonetAtmPlcpYellow Plcp Yellow alarm was detected in the
incoming PLCP frame stream.
Parsed from file Fore-TC-MIB.mib
Module: Fore-TC-MIB
Vendor: Fore Systems, Inc.
Module: Fore-TC-MIB
[Automatically extracted from oidview.com]
foreTcConfigStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the ATM Status of the interface. The variable is a bit map represented as a sum, therefore it can represent multiple defects simultaneously. The sonetAtmNoDefect should be set if and only if no other flag is set. The various bit mask values are: 1 sonetAtmNoDefect 2 sonetAtmLCD Loss of Cell Delineation was detected. LCD is declared when a 'normal pointer value' is not found for eight consecutive frames. 4 sonetAtmPlcpLOF Valid PLCP frames were not detected at the interface. 8 sonetAtmPlcpYellow Plcp Yellow alarm was detected in the incoming PLCP frame stream." DEFVAL { 1 } ::= { foreTcConfigEntry 5 }
foreTcConfigStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the ATM Status of the interface. The variable is a bit map represented as a sum, therefore it can represent multiple defects simultaneously. The sonetAtmNoDefect should be set if and only if no other flag is set. The various bit mask values are: 1 sonetAtmNoDefect 2 sonetAtmLCD Loss of Cell Delineation was detected. LCD is declared when a 'normal pointer value' is not found for eight consecutive frames. 4 sonetAtmPlcpLOF Valid PLCP frames were not detected at the interface. 8 sonetAtmPlcpYellow Plcp Yellow alarm was detected in the incoming PLCP frame stream." DEFVAL { 1 } ::= { foreTcConfigEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.2.2.1.1.12.1.1.1 | foreTcConfigCellScrambling | 0 | 0 | This variable indicates if cell payload scrambling is enabled. If enabled, all outgoing cell payloads are scrambled via the X**4… |
1.3.6.1.4.1.326.2.2.1.1.12.1.1.2 | foreTcConfigEmptyCell | 0 | 0 | This variable indicates the type of ATM cells inserted into the outgoing data stream when there is no real data to send. There a… |
1.3.6.1.4.1.326.2.2.1.1.12.1.1.3 | foreTcConfigLoopback | 0 | 0 | This variable indicates if cell loopback is enabled at the TC layer. There are three choices: tcNoLoop - Normal operating mode, … |
1.3.6.1.4.1.326.2.2.1.1.12.1.1.4 | foreTcConfigFramingMode | 0 | 0 | This variable configures and indicates the method used to encapsulate ATM cells in the data stream. There are two choices: tcFrami… |