The total number of connections (either multicast or
unicast) that this network module can support.
The largest possible number of ATM connections can be 2^28 - 1
(i.e., 268435455) since VPI and VCI fields in the ATM cell
header occupies a total of 28 bits (12 bits of VPI and 16 bits
of VCI). Any value greater than 2^28 - 1 for this MIB will
indicate that this network module can support an unlimited
number of connections.
Parsed from file fore-switch.mib.txt
Company: None
Module: Fore-Switch-MIB
The total number of connections (either multicast or
unicast) that this network module can support.
The largest possible number of ATM connections can be 2^28 - 1
(i.e., 268435455) since VPI and VCI fields in the ATM cell
header occupies a total of 28 bits (12 bits of VPI and 16 bits
of VCI). Any value greater than 2^28 - 1 for this MIB will
indicate that this network module can support an unlimited
number of connections.
Parsed from file Fore-Switch-MIB.mib
Module: Fore-Switch-MIB
Vendor: Fore Systems, Inc.
Module: Fore-Switch-MIB
[Automatically extracted from oidview.com]
nGenericShmemMaxConnections OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of connections (either multicast or unicast) that this network module can support. The largest possible number of ATM connections can be 2^28 - 1 (i.e., 268435455) since VPI and VCI fields in the ATM cell header occupies a total of 28 bits (12 bits of VPI and 16 bits of VCI). Any value greater than 2^28 - 1 for this MIB will indicate that this network module can support an unlimited number of connections." ::= { netmodGenericShmemEntry 9 }
nGenericShmemMaxConnections OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of connections (either multicast or unicast) that this network module can support. The largest possible number of ATM connections can be 2^28 - 1 (i.e., 268435455) since VPI and VCI fields in the ATM cell header occupies a total of 28 bits (12 bits of VPI and 16 bits of VCI). Any value greater than 2^28 - 1 for this MIB will indicate that this network module can support an unlimited number of connections." ::= { netmodGenericShmemEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.2.2.1.5.9.1.1.1 | nGenericShmemBoard | 0 | 0 | The index of this board within the ATM switch. |
1.3.6.1.4.1.326.2.2.1.5.9.1.1.2 | nGenericShmemModule | 0 | 0 | The number of this network module within the switch board. |
1.3.6.1.4.1.326.2.2.1.5.9.1.1.3 | nGenericShmemSubindex | 0 | 0 | The subindex of this generic shmem within the network module. |
1.3.6.1.4.1.326.2.2.1.5.9.1.1.4 | nGenericShmemCurrentUcastConnections | 0 | 0 | The current number of unicast connections active on this network module. If a separate unicast connection space is not supported,… |
1.3.6.1.4.1.326.2.2.1.5.9.1.1.5 | nGenericShmemCurrentMcastConnections | 0 | 0 | The current number of multicast connections active on this network module. If a separate multicast connection space is not suppor… |
1.3.6.1.4.1.326.2.2.1.5.9.1.1.6 | nGenericShmemCurrentConnections | 0 | 0 | The current number of connections (either multicast or unicast) active on this network module. |
1.3.6.1.4.1.326.2.2.1.5.9.1.1.7 | nGenericShmemMaxUcastConnections | 0 | 0 | The total number of unicast connections that this network module can support. If a separate unicast connection space is not suppo… |
1.3.6.1.4.1.326.2.2.1.5.9.1.1.8 | nGenericShmemMaxMcastConnections | 0 | 0 | The total number of multicast connections that this network module can support. If a separate multicast connection space is not s… |