switchtimeZone
View at oid-info.com
The TimeZone configured for this ATM switch.
This variable follows the POSIX standard 1003.1-1988
for the format of the TZ environment variable. In
particular, it is general enough to specify the rules
for converting from Standard to Daylight Savings time
for most timezones of the world.
By default, the switch has the rules built in for
the following timezones:
EST5EDT
CST6CDT
MST7MDT
PST8PDT
AKST9AKDT.
Locales outside of these timezones will need to
supply the appropriate rule for switching between
Daylight and Standard time.
Parsed from file fore-switch.mib.txt
Company: None
Module: Fore-Switch-MIB
The TimeZone configured for this ATM switch.
This variable follows the POSIX standard 1003.1-1988
for the format of the TZ environment variable. In
particular, it is general enough to specify the rules
for converting from Standard to Daylight Savings time
for most timezones of the world.
By default, the switch has the rules built in for
the following timezones:
EST5EDT
CST6CDT
MST7MDT
PST8PDT
AKST9AKDT.
Locales outside of these timezones will need to
supply the appropriate rule for switching between
Daylight and Standard time.
Parsed from file Fore-Switch-MIB.mib
Module: Fore-Switch-MIB
Vendor: Fore Systems, Inc.
Module: Fore-Switch-MIB
[Automatically extracted from oidview.com]
switchTimeZone OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The TimeZone configured for this ATM switch. This variable follows the POSIX standard 1003.1-1988 for the format of the TZ environment variable. In particular, it is general enough to specify the rules for converting from Standard to Daylight Savings time for most timezones of the world. By default, the switch has the rules built in for the following timezones: EST5EDT CST6CDT MST7MDT PST8PDT AKST9AKDT. Locales outside of these timezones will need to supply the appropriate rule for switching between Daylight and Standard time. " ::= { switchGroup 14 }
switchTimeZone OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The TimeZone configured for this ATM switch. This variable follows the POSIX standard 1003.1-1988 for the format of the TZ environment variable. In particular, it is general enough to specify the rules for converting from Standard to Daylight Savings time for most timezones of the world. By default, the switch has the rules built in for the following timezones: EST5EDT CST6CDT MST7MDT PST8PDT AKST9AKDT. Locales outside of these timezones will need to supply the appropriate rule for switching between Daylight and Standard time. " ::= { switchGroup 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.2.2.2.1.1.14.0 | switchTimeZone | 0 | 0 | switchtimeZone |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.2.2.2.1.1.1 | hardwareVersion | 1 | 1 | The version of the ATM switch hardware in hex. The version number 0x1 is revision A, 0x2 is revision B etc. Version number 0x0 re… |
1.3.6.1.4.1.326.2.2.2.1.1.2 | softwareVersion | 1 | 1 | The version of the ATM switch control software in hex. The version number is encoded into 6 hex digits. For example, version 1.2.… |
1.3.6.1.4.1.326.2.2.2.1.1.3 | maxPaths | 1 | 1 | The maximum number of input VPIs (Virtual Path Identifies). |
1.3.6.1.4.1.326.2.2.2.1.1.4 | maxChannels | 1 | 1 | The maximum number of input VCIs (Virtual Channel Identifiers). |
1.3.6.1.4.1.326.2.2.2.1.1.5 | atmAddress | 1 | 1 | The address of this ATM switch. |
1.3.6.1.4.1.326.2.2.2.1.1.6 | uptime | 1 | 1 | The length of time this ATM switch has been up, in hundredths of a second. |
1.3.6.1.4.1.326.2.2.2.1.1.7 | switchCDV | 1 | 1 | The switch Cell Delay Variation (CDV) specified in microseconds, indicates the time window in which a cell may be received on a c… |
1.3.6.1.4.1.326.2.2.2.1.1.8 | switchPolicingAction | 1 | 1 | This object indicates the action the switch will take in case of bandwidth violation. The switchPolicingAction is the default pol… |
1.3.6.1.4.1.326.2.2.2.1.1.9 | softwareVersionText | 1 | 1 | The version of the ATM switch control software. This object provides text information about the internal software configuration t… |
1.3.6.1.4.1.326.2.2.2.1.1.10 | switchType | 1 | 1 | switchtype |
1.3.6.1.4.1.326.2.2.2.1.1.12 | switchReservedPMPMinVCI | 1 | 1 | The minimum VCI that is reserved for PMP connections. |
1.3.6.1.4.1.326.2.2.2.1.1.13 | switchReservedPMPMaxVCI | 1 | 1 | The maximum VCI that is reserved for PMP connections. |
1.3.6.1.4.1.326.2.2.2.1.1.15 | switchGMTime | 1 | 1 | The switch's notion of Greenwich Mean Time. Linked to hrSystemDate. Offset part of time spec, if supplied, is considered an erro… |
1.3.6.1.4.1.326.2.2.2.1.1.16 | switchProtocolType | 1 | 1 | The transfer protocol that is used when upgrading the switch software, backing up the CDB, etc. |
1.3.6.1.4.1.326.2.2.2.1.1.17 | switchCurrentUserid | 1 | 1 | The value of this object identifies the user currently logged in or attempting to log in on the switch. It would be a NULL string… |
1.3.6.1.4.1.326.2.2.2.1.1.18 | switchCurrentLoginFrom | 1 | 1 | This string gives the IP address of the host from where the current user is logged in or attempting to log in. A NULL string is r… |
1.3.6.1.4.1.326.2.2.2.1.1.19 | switchPrimaryClock | 1 | 1 | The port number whose 8KHz clock is used as primary clock by all the netmods on all the boards in this switch. |
1.3.6.1.4.1.326.2.2.2.1.1.20 | switchSecondaryClock | 1 | 1 | The port number whose 8KHz clock is used as secondary clock by all the netmods on all the boards in this switch. |
1.3.6.1.4.1.326.2.2.2.1.1.21 | switchClockOperStatus | 1 | 1 | The currently active 8KHz clock configuration. The crystal?Clock types are not currently used. The default mode is localCrystalC… |
1.3.6.1.4.1.326.2.2.2.1.1.22 | switchTimingMode | 1 | 1 | switchtimingMode |
1.3.6.1.4.1.326.2.2.2.1.1.23 | switchConnectionPreservation | 1 | 1 | When connection preservation is enabled the switch will not reset the hardware when a fail-over or software-reboot occurs. The s… |
1.3.6.1.4.1.326.2.2.2.1.1.24 | switchATMLayerOAM | 1 | 1 | This object specifies whether the processing of ATM layer OAM cells by this switch is enabled or disabled. |
1.3.6.1.4.1.326.2.2.2.1.1.25 | switchHttpServer | 1 | 1 | This specifies whether the embedded HTTP Server (which is used for the element manager) is enabled or disabled. |
1.3.6.1.4.1.326.2.2.2.1.1.26 | switchHttpHelpUrl | 1 | 1 | This specifies the URL path for the local depository of the WWW help pages for the web-based element manager on the switch. The … |
1.3.6.1.4.1.326.2.2.2.1.1.27 | mcastGroup | 1 | 5 | None |
1.3.6.1.4.1.326.2.2.2.1.1.28 | switchCtrlLinkid | 1 | 1 | The linkid of the ctrl port on this switch. |
1.3.6.1.4.1.326.2.2.2.1.1.29 | switchClockCurrentStatus | 1 | 1 | The currently active 8KHz clock configuration. The value would indicate primary Clock or secondary Clock or if neither is availab… |
1.3.6.1.4.1.326.2.2.2.1.1.30 | switchDebounceTable | 1 | 4 | A table, where each entry consists of debounce information associated with a unique port. This information includes the hysteresi… |
1.3.6.1.4.1.326.2.2.2.1.1.31 | softwareLicenseKey | 1 | 1 | The software license key of this switch. |
1.3.6.1.4.1.326.2.2.2.1.1.32 | switchCounterResetTime | 1 | 1 | Indicates when all switch (except for virtual connection) counters were reset. The TimeStamp is equal to the sysUpTime when the … |
1.3.6.1.4.1.326.2.2.2.1.1.33 | switchCounterReset | 1 | 1 | Writing a value of resetRequest will result in a reset of all counters on the switch except for VCC indexed counters. Writing a … |
1.3.6.1.4.1.326.2.2.2.1.1.34 | switchSbprServerAddressTable | 1 | 11 | A table, where each entry consists of a static list of 5 bootp address entries. |
1.3.6.1.4.1.326.2.2.2.1.1.35 | switchPrimaryClockPort | 1 | 1 | The name of the hardware port whose 8KHz clock is used as primary clock by all the netmods on all the boards in this switch. |
1.3.6.1.4.1.326.2.2.2.1.1.36 | switchSecondaryClockPort | 1 | 1 | The name of the hardware port whose 8KHz clock is used as secondary clock by all the netmods on all the boards in this switch. |
1.3.6.1.4.1.326.2.2.2.1.1.37 | serviceCategoryTable | 1 | 3 | A table of ATM service categories supported. |
1.3.6.1.4.1.326.2.2.2.1.1.38 | switchPmpEnable | 1 | 1 | Disabling the PMP Feature disallows any point to multipoint connections. The services which require point to multi point connecti… |
1.3.6.1.4.1.326.2.2.2.1.1.39 | switchCallPreservation | 1 | 1 | When SVx/SPVx Preservation is enabled, existing switched connections will be preserved during transfers of switch control from th… |