The factor to derive holding timer from configuration
timer. This value when multipled by a configuration timer
yields the value of the holding timer parameter issued
with configuration information. The semantics of this
parameter are such that it is permissible to add a delta
value to the result to compensate for possible delays and
imprecision of timers. The result of the calculation is
truncated, upon overflow, to the maximum value for the
parameter permitted by the protocol (65535).
Parsed from file it-isis-mib.mib.txt
Company: None
Module: ITOUCH-ISIS-MIB
The factor to derive holding timer from configuration
timer. This value when multipled by a configuration timer
yields the value of the holding timer parameter issued
with configuration information. The semantics of this
parameter are such that it is permissible to add a delta
value to the result to compensate for possible delays and
imprecision of timers. The result of the calculation is
truncated, upon overflow, to the maximum value for the
parameter permitted by the protocol (65535).
Parsed from file ITOUCHHUB.mib
Module: ITOUCHHUB
xIsisCircISHoldTimerMult OBJECT-TYPE SYNTAX INTEGER (2..63) ACCESS read-only STATUS mandatory DESCRIPTION "The factor to derive holding timer from configuration timer. This value when multipled by a configuration timer yields the value of the holding timer parameter issued with configuration information. The semantics of this parameter are such that it is permissible to add a delta value to the result to compensate for possible delays and imprecision of timers. The result of the calculation is truncated, upon overflow, to the maximum value for the parameter permitted by the protocol (65535)." REFERENCE "ANSI {NLM.aoi holdingTimerMutliplier (20)}" ::= { xIsisCircISEntry 5 }
Vendor: MRV Communications, In-Reach Product Division
Module: ITOUCH-ISIS-MIB
[Automatically extracted from oidview.com]
xIsisCircISHoldTimerMult OBJECT-TYPE SYNTAX INTEGER (2..63) ACCESS read-only STATUS mandatory DESCRIPTION "The factor to derive holding timer from configuration timer. This value when multipled by a configuration timer yields the value of the holding timer parameter issued with configuration information. The semantics of this parameter are such that it is permissible to add a delta value to the result to compensate for possible delays and imprecision of timers. The result of the calculation is truncated, upon overflow, to the maximum value for the parameter permitted by the protocol (65535)." REFERENCE "ANSI {NLM.aoi holdingTimerMutliplier (20)}" ::= { xIsisCircISEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.26.2.2.1.1 | xIsisCircISSysInstance | 0 | 0 | The identifier of the Integrated IS-IS instance to which this row corresponds. This object follows the index and manualOrAutomati… |
1.3.6.1.4.1.33.26.2.2.1.2 | xIsisCircISIndex | 0 | 0 | The unique identifier of this row. This value is the same as the value of the ifIndex object which identifies the interface which… |
1.3.6.1.4.1.33.26.2.2.1.3 | xIsisCircISExistState | 0 | 0 | The existence state of this row. This object follows the ExistenceState behaviour. |
1.3.6.1.4.1.33.26.2.2.1.4 | xIsisCircISOperState | 0 | 0 | The operational state of the row. This object follows the operationalState behaviour. |
1.3.6.1.4.1.33.26.2.2.1.6 | xIsisCircISConfTimer | 0 | 0 | xIsisCircISConftimer |
1.3.6.1.4.1.33.26.2.2.1.7 | xIsisCircISSuggESConfTimer | 0 | 0 | xIsisCircISSuggESConftimer |
1.3.6.1.4.1.33.26.2.2.1.8 | xIsisCircISRedHoldTime | 0 | 0 | The holding time (in seconds) to be specified in Redirect PDUs generated by the system on this circuit. |
1.3.6.1.4.1.33.26.2.2.1.9 | xIsisCircISESReachChgs | 0 | 0 | Count of the number of changes in reachability of End Systems from this circuit. |
1.3.6.1.4.1.33.26.2.2.1.10 | xIsisCircISInv9542PDUs | 0 | 0 | Counter of invalid 9542 PDUs received. This is the number of ISO 9452 PDUs received which are discarded as a result of the PDU He… |