Vendor: MICOM Communication Corporation
Module: MICOM-FRAMERELAY-MIB
[Automatically extracted from oidview.com]
mcmFrGlobalGroup OBJECT IDENTIFIER ::= {fr-configuration 1}
mcmFrGlobalGroup OBJECT IDENTIFIER ::= {fr-configuration 1}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.335.1.4.7.1.1.1 | mcmFrMaxDLCI | 1 | 1 | NAME = ; DESC = The maximum number of DLCIs that \ may be configured for the entire \ box; HELP = ; CAPABILITIES = NET_CFG, VPN_DISP; |
1.3.6.1.4.1.335.1.4.7.1.1.2 | mcmFrMaxVirtualPorts | 1 | 1 | NAME = ; DESC = The maximum number of Virtual Ports that \ may be configured for the entire \ box; HELP = ; CAPABILITIES = NET_CFG, … |
1.3.6.1.4.1.335.1.4.7.1.1.3 | mcmFrMaxDlciPerLine | 1 | 1 | NAME = ; DESC = The maximum number of DLCIs that may \ be configured for a Frame Relay line; HELP = ; CAPABILITIES = NET_CFG, VPN_D… |
1.3.6.1.4.1.335.1.4.7.1.1.4 | mcmFrConnectTime | 1 | 1 | NAME = ; DESC = The sysUpTime when the FR Driver was \ initialized; HELP = ; CAPABILITIES = NET_CFG, VPN_DISP; |
1.3.6.1.4.1.335.1.4.7.1.1.5 | mcmFrOctetsSent | 1 | 1 | NAME = ; DESC = Total number of Frame Relay Information \ field octets that were sent out all FR \ ports; HELP = ; CAPABILITIES = NE… |
1.3.6.1.4.1.335.1.4.7.1.1.6 | mcmFrOctetsReceived | 1 | 1 | NAME = ; DESC = Total number of Frame Relay Information \ Field octets that were received across all \ FR ports; HELP = ; CAPABILITI… |
1.3.6.1.4.1.335.1.4.7.1.1.7 | mcmFrFramesSent | 1 | 1 | NAME = ; DESC = Total number of Frame Relay Frames \ sent out all FR ports; HELP = ; CAPABILITIES = NET_CFG, VPN_DISP; |
1.3.6.1.4.1.335.1.4.7.1.1.8 | mcmFrFramesReceived | 1 | 1 | NAME = ; DESC = Total number of Frame Relay Frames \ received in on all FR ports; HELP = CAPABILITIES = NET_CFG, VPN_DISP; |
1.3.6.1.4.1.335.1.4.7.1.1.9 | mcmFrGlobalGroupCntrAction | 1 | 1 | NAME = ; DESC = This object has been OBSOLETED for software \ releases beginning with Release 3.0. \ Setting this object to reset… |
1.3.6.1.4.1.335.1.4.7.1.1.10 | mcmFrDNANumberingPlan | 1 | 1 | NAME = ; DESC = The value of this object designates the \ numbering plan of the DNA; HELP = The number plan is used in conjunction… |
1.3.6.1.4.1.335.1.4.7.1.1.11 | mcmFrActivePanlDlciSVCs | 1 | 1 | NAME = ; DESC = The number of active PANL DLCI SVCs \ for all FR ports.; HELP = ; CAPABILITIES = NET_CFG, VPN_DISP; |
1.3.6.1.4.1.335.1.4.7.1.1.12 | mcmFrTotalTunnelingPVCs | 1 | 1 | NAME = ; DESC = The total number of tunneling PVCs configured.; HELP = ; CAPABILITIES = NET_CFG, VPN_DISP; |
1.3.6.1.4.1.335.1.4.7.1.1.13 | mcmFrActiveTunnelingPVCs | 1 | 1 | NAME = ; DESC = The number of active tunneling PVCs configured.; HELP = ; CAPABILITIES = NET_CFG, VPN_DISP; |
1.3.6.1.4.1.335.1.4.7.1.1.14 | mcmFrPanlLmiTrapEnable | 1 | 1 | NAME = ; DESC = This object indicates whether the generation of \ Trap messages are enabled/disabled for the FR \ PANL LMI module.… |
1.3.6.1.4.1.335.1.4.7.1.1.15 | mcmFrMsmTrapEnable | 1 | 1 | NAME = ; DESC = This object indicates whether the generation of \ Trap messages are enabled/disabled for the FR \ MSM module.; HELP… |
1.3.6.1.4.1.335.1.4.7.1.1.16 | mcmFrCoreTrapEnable | 1 | 1 | NAME = ; DESC = This object indicates whether the generation of \ Trap messages are enabled/disabled for the FR \ Core module.; HEL… |
1.3.6.1.4.1.335.1.4.7.1.1.17 | mcmFrPlmTrapEnable | 1 | 1 | NAME = ; DESC = This object indicates whether the generation of \ Trap messages are enabled/disabled for the FR \ Plm module.; HELP… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.335.1.4.7.1.2 | mcmFrPhyPortTable | 1 | 44 | NAME = ; DESC = Table of physical port entries \ containing flow control info \ and statistics; HELP = ; CAPABILITIES = NET_CFG, VPN… |
1.3.6.1.4.1.335.1.4.7.1.3 | mcmFrPVCPhyTable | 1 | 4 | NAME = ; DESC = Table that extends the RFC 1315 \ DLCMI table contianing info \ about the PVC LMI; HELP = ; CAPABILITIES = NET_CFG, … |
1.3.6.1.4.1.335.1.4.7.1.4 | mcmFrSVCPhyTable | 1 | 20 | NAME = ; DESC = Table containing the SVC default \ parameters ; HELP = Table containing default SVC \ parameters to be used if none… |
1.3.6.1.4.1.335.1.4.7.1.5 | mcmFrVirtualPortTable | 1 | 9 | NAME = ; DESC = Table to define the virtual port; HELP = Table to provide the mapping between \ virtual ports and physical ports \… |
1.3.6.1.4.1.335.1.4.7.1.6 | mcmFrSVCMapTable | 1 | 22 | NAME = ; DESC = Table for SVC to VP bindings; HELP = This table will give the SVC \ DNA address to be bound to the \ specified Virt… |
1.3.6.1.4.1.335.1.4.7.1.7 | mcmFrPVCMapTable | 1 | 6 | NAME = ; DESC = This table has been OBSOLETED for software \ releases beginning with Release 3.0. \ Table for PVC to VP bindings; H… |
1.3.6.1.4.1.335.1.4.7.1.8 | mcmFrSVCCircuitTable | 1 | 31 | NAME = ; DESC = Table of entries for SVCs on this \ access device; HELP = A table containing information \ about specific SVC Data … |
1.3.6.1.4.1.335.1.4.7.1.9 | nvmFrGlobalGroup | 8 | 16 | None |
1.3.6.1.4.1.335.1.4.7.1.10 | nvmFrPhyPortTable | 1 | 16 | NAME = ; DESC = Table of physical port entries \ contianing flow control info and \ statistics; HELP = ; CAPABILITIES = NET_CFG, VPN… |
1.3.6.1.4.1.335.1.4.7.1.11 | nvmFrPVCPhyTable | 1 | 4 | NAME = ; DESC = Table that extends the RFC 1315 \ DLCMI table contianing info \ about the PVC LMI; HELP = ; CAPABILITIES = NET_CFG, … |
1.3.6.1.4.1.335.1.4.7.1.12 | nvmFrSVCPhyTable | 1 | 20 | NAME = ; DESC = Table containing the SVC default \ parameters ; HELP = Table containing default SVC \ parameters to be used if none… |
1.3.6.1.4.1.335.1.4.7.1.13 | nvmFrVirtualPortTable | 1 | 8 | NAME = ; DESC = Table to provide the mapping between \ virtual ports and physical ports \ and to define the virtual port \ paramete… |
1.3.6.1.4.1.335.1.4.7.1.14 | nvmFrSVCMapTable | 1 | 20 | NAME = ; DESC = Table for SVC to VP bindings; HELP = This table will give the SVC \ DNA address to be bound to the \ specified Virt… |
1.3.6.1.4.1.335.1.4.7.1.15 | nvmFrPVCMapTable | 1 | 5 | NAME = ; DESC = This table has been OBSOLETED for software \ releases beginning with Release 3.0. \ Table for PVC to VP bindings; H… |
1.3.6.1.4.1.335.1.4.7.1.16 | nvmFrDlcmiTable | 1 | 11 | NAME = ; DESC = The Parameters for the Data Link Connection \ Management Interface for the frame \ relay service on this interface… |
1.3.6.1.4.1.335.1.4.7.1.17 | mcmFrAllSVCCircuitTable | 1 | 32 | NAME = ; DESC = Table of entries for all SVCs on this \ access device.; HELP = A table containing information \ about specific SVC … |
1.3.6.1.4.1.335.1.4.7.1.18 | mcmFrLANSpvcTable | 1 | 12 | NAME = ; DESC = The Frame Relay LAN SPVC Connections \ table(Operational); HELP = ; CAPABILITIES =NET_CFG, VPN_CFG; |
1.3.6.1.4.1.335.1.4.7.1.19 | mcmFrLANSpvcSVCTable | 1 | 20 | NAME = ; DESC = The Frame Relay SVC Connect (Switched) \ Segment Configuration table. HELP = ; CAPABILITIES =NET_CFG, VPN_CFG; |
1.3.6.1.4.1.335.1.4.7.1.20 | nvmFrLANSpvcTable | 1 | 7 | NAME = ; DESC = The Frame Relay LAN SPVC Connections \ table(Configurational); HELP = ; CAPABILITIES =NET_CFG, VPN_CFG; |
1.3.6.1.4.1.335.1.4.7.1.21 | nvmFrLANSpvcSVCTable | 1 | 17 | NAME = ; DESC = The Frame Relay SVC Connect (Switched) \ Segment Configuration table. HELP = ; CAPABILITIES =NET_CFG, VPN_CFG; |
1.3.6.1.4.1.335.1.4.7.1.22 | mcmFrDlcmiSVCStatusTable | 1 | 10 | NAME = ; DESC = Table of entries for Frame Relay Dlcmi SVC \ status for this access device. (Operational); HELP =; CAPABILITIES = N… |
1.3.6.1.4.1.335.1.4.7.1.23 | mcmFrTunnelPvcTable | 1 | 26 | NAME = ; DESC = Table of entries for Frame Relay Tunnel PVCs \ for this access device. (Operational); HELP =; CAPABILITIES = NET_CF… |
1.3.6.1.4.1.335.1.4.7.1.24 | nvmFrTunnelPvcTable | 1 | 18 | NAME = ; DESC = Table of entries for Frame Relay Tunnel PVCs \ for this access device. (Configuration); HELP =; CAPABILITIES = NET_… |
1.3.6.1.4.1.335.1.4.7.1.25 | mcmFrNetlinkMapTable | 1 | 4 | NAME = ; DESC = Table for mapping Netlinks (Tunnel PVC ifIndex \ values) to Virtual Ports. (Operational); HELP = ; CAPABILITIES = N… |
1.3.6.1.4.1.335.1.4.7.1.26 | nvmFrNetlinkMapTable | 1 | 4 | NAME = ; DESC = Table for mapping Netlinks (Tunnel PVC ifIndex \ values) to Virtual Ports. (Configuration); HELP = ; CAPABILITIES =… |