This member is the targeted processor clock
frequency expressed in terms of a specific
factor of the system clock. Possible options
are factor of 2 or 3. See
platformTargetInterconnectClockFreq for more
detail.
A possible Blackbird processor would use the
3:2 ratio.
Parsed from file e10k_mib.txt
Company: None
Module: CRI-SERVER-MIB
This member is the targeted processor clock
frequency expressed in terms of a specific
factor of the system clock. Possible options
are factor of 2 or 3. See
platformTargetInterconnectClockFreq for more
detail.
A possible Blackbird processor would use the
3:2 ratio.
Parsed from file CRI-SERVER-MIB.mib
Module: CRI-SERVER-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
platformTargetProcClockMultiple OBJECT-TYPE SYNTAX INTEGER { two-to-one (1), three-to-one (2), three-to-two (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This member is the targeted processor clock frequency expressed in terms of a specific factor of the system clock. Possible options are factor of 2 or 3. See platformTargetInterconnectClockFreq for more detail. A possible Blackbird processor would use the 3:2 ratio." ::= { platform 9 }
platformTargetProcClockMultiple OBJECT-TYPE SYNTAX INTEGER { two-to-one (1), three-to-one (2), three-to-two (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This member is the targeted processor clock frequency expressed in terms of a specific factor of the system clock. Possible options are factor of 2 or 3. See platformTargetInterconnectClockFreq for more detail. A possible Blackbird processor would use the 3:2 ratio." ::= { platform 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.34.2.1.1.9.0 | platformTargetProcClockMultiple | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.34.2.1.1.1 | platformType | 1 | 1 | The platform type. Currently, only one platform is defined: Starfire. There is no plan to backport to CS6400 yet. |
1.3.6.1.4.1.34.2.1.1.2 | platformName | 1 | 1 | The name assigned to a physical machine. |
1.3.6.1.4.1.34.2.1.1.3 | platformAmbientTemp | 1 | 1 | The current ambient temperature of the platform. The temperature will be in Celsius. |
1.3.6.1.4.1.34.2.1.1.4 | platformReset | 1 | 1 | This member resets the platform. |
1.3.6.1.4.1.34.2.1.1.5 | platformInterconnectClockFreq | 1 | 1 | This member is the current interconnect frequency of the platform. The unit is in Hz. |
1.3.6.1.4.1.34.2.1.1.6 | platformProcClockFreq | 1 | 1 | This member is the current processor clock frequency of the platform. The unit is in Hz. |
1.3.6.1.4.1.34.2.1.1.7 | platformJtagClockFreq | 1 | 1 | This member is the current JTAG clock frequency of the platform. The unit is in Hz. Note: this member is only measurable in the re… |
1.3.6.1.4.1.34.2.1.1.8 | platformTargetInterconnectClockFreq | 1 | 1 | This member is the targeted interconnect clock frequency. The unit is in Hz and the valid range is between 40,000,000 Hz and 120,0… |
1.3.6.1.4.1.34.2.1.1.10 | platformTargetJtagClockFreq | 1 | 1 | This member is the targeted JTAG clock frequency. The unit is in Hz. See platformTargetSystemClockFreq for more detail. |
1.3.6.1.4.1.34.2.1.1.11 | platformMasterConBrd | 1 | 1 | This member is the master control board number. |
1.3.6.1.4.1.34.2.1.1.12 | platformSysClkConBrd | 1 | 1 | This member is the control board providing system clock to the platform. |