Reference record for OID 1.3.6.1.4.1.343.2.10.3.4.1.129



parent
1.3.6.1.4.1.343.2.10.3.4.1 (dmtfGroups)
node code
129
node name
tPhysicalExpansionSitesTable
dot oid
1.3.6.1.4.1.343.2.10.3.4.1.129
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) intel(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) intelRmm2(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) intel(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) intelRmm2(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) intel(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) intelRmm2(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) intel(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) intelRmm2(343) products(2) server-management(10) software(3) basebrd4(4) dmtfGroups(1) tPhysicalExpansionSitesTable(129)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/intel/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • /iso/identified-organization/dod/internet/private/enterprise/intelRmm2/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/intel/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • /iso/org/dod/internet/private/enterprise/intelRmm2/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • /iso/org/dod/internet/private/enterprises/intel/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • /iso/org/dod/internet/private/enterprises/intelRmm2/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/intel/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/intelRmm2/products/server-management/software/basebrd4/dmtfGroups/tPhysicalExpansionSitesTable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/343/2/10/3/4/1/129

    Description by circitor

    This global table describes all of the expansion sites in
    this expandable component in the system. The unique index of each expansion
    site is the key into thistable. Card/Bus slots, disk bays, hot-plug power
    supply bays, etc., are all examples of expansion sites.

    Parsed from file INTELCORPORATIONBASEBOARD-MIB.mib
    Module: INTELCORPORATIONBASEBOARD-MIB

    Information by oid_info

    Vendor: Intel Corporation
    Module: INTELCORPORATIONBASEBOARD-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    tPhysicalExpansionSitesTable OBJECT-TYPE SYNTAX SEQUENCE OF SPhysicalExpansionSitesTable ACCESS not-accessible STATUS mandatory DESCRIPTION "This global table describes all of the expansion sites in this expandable component in the system. The unique index of each expansion site is the key into thistable. Card/Bus slots, disk bays, hot-plug power supply bays, etc., are all examples of expansion sites." ::= {dmtfGroups 129}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.343)

    Kaminski Adam

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.343.2.10.3.4.1.129.1 ePhysicalExpansionSitesTable 6 6 None

    Brothers (51)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.343.2.10.3.4.1.1 tComponentid 1 7 This group defines the attributes common to all components.
    This groupis required.
    1.3.6.1.4.1.343.2.10.3.4.1.2 tGeneralInformation 1 7 This group defines general information about this system.
    1.3.6.1.4.1.343.2.10.3.4.1.4 tSystemBios 1 10 This group defines the attributes for the System BIOS.
    1.3.6.1.4.1.343.2.10.3.4.1.5 tSystemBiosCharacteristics 1 5 This group defines the characteristics of the System BIOS.
    1.3.6.1.4.1.343.2.10.3.4.1.6 tProcessor 1 14 This group defines the attributes for each and every processor
    installed in this system.
    1.3.6.1.4.1.343.2.10.3.4.1.7 tMotherboard 1 4 This group defines attributes for the motherboard.
    1.3.6.1.4.1.343.2.10.3.4.1.10 tSystemCache 1 10 This group defines the attributes for different System Caches
    installed inthis system.
    1.3.6.1.4.1.343.2.10.3.4.1.17 tPowerSupply 1 22 This group defines various attributes for power supplies
    in this system.
    1.3.6.1.4.1.343.2.10.3.4.1.19 tSystemSlots 1 16 This group defines the attributes for the different system
    expansion slotssupportedin this system.
    1.3.6.1.4.1.343.2.10.3.4.1.28 tCoolingUnitGlobalTable 1 3 This global table describes all of the Cooling Units in this
    system component. The unique index of each Cooling Unit is a key i…
    1.3.6.1.4.1.343.2.10.3.4.1.30 tFieldReplaceableUnit 1 13 A Field Replaceable Unit (FRU), is defined as a hardware
    componentwhich is designed to be separately removable for replacement o…
    1.3.6.1.4.1.343.2.10.3.4.1.31 tOperationalState 1 12 This group provides the operational state, usage, and availabili
    y status,and administrative state indicators for specific Devic…
    1.3.6.1.4.1.343.2.10.3.4.1.34 tPhysicalMemoryArray 1 18 This group represents an array of physical memory as a collectio
    ofone or more Memory Devices associated in sets and partitions.
    1.3.6.1.4.1.343.2.10.3.4.1.35 tMemoryArrayMappedAddresses 1 8 This table presents ranges of physical addresses that are
    mapped to agiven Memory Array.
    1.3.6.1.4.1.343.2.10.3.4.1.36 tMemoryDevice 1 24 This group presents information about individual memory devices
    in thesystem. A memory device can be a SIMM, a SIPP, or a single…
    1.3.6.1.4.1.343.2.10.3.4.1.37 tMemoryDeviceMappedAddresses 1 9 This table presents ranges of physical addresses that are
    mapped to agiven Memory Device Set.
    1.3.6.1.4.1.343.2.10.3.4.1.50 tSystemHardwareSecurity 1 5 This group describes the system-wide hardware security settings.
    1.3.6.1.4.1.343.2.10.3.4.1.52 tSystemPowerControls 1 4 This group defines attributes for controlling the main power
    supply tothe system.
    1.3.6.1.4.1.343.2.10.3.4.1.54 tVoltageProbe 1 22 This group defines the attributes for the voltage probes
    in this system.
    1.3.6.1.4.1.343.2.10.3.4.1.55 tTemperatureProbe 1 22 This group defines the attributes for the temperature probes
    in thissystem.
    1.3.6.1.4.1.343.2.10.3.4.1.64 tPhysicalContainerGlobalTable 1 13 This group of attributes describes the fields in a row ofthe
    Physical Container Global Table. This table lists all ofthe contain…
    1.3.6.1.4.1.343.2.10.3.4.1.66 tOperatingSystem 1 9 This group defines general information about operating systems
    installedon this system.
    1.3.6.1.4.1.343.2.10.3.4.1.67 tPowerUnitGlobalTable 1 3 This global table describes all of the Power Units in this
    system component. The unique index of each Power Unit is the keyinto …
    1.3.6.1.4.1.343.2.10.3.4.1.74 tParallelPorts 1 11 This group defines the attributes for parallel ports in this
    system.
    1.3.6.1.4.1.343.2.10.3.4.1.75 tSerialPorts 1 10 This group defines the attributes for serial ports in this
    system.
    1.3.6.1.4.1.343.2.10.3.4.1.81 tCoolingDevice 1 7 This group defines various attributes for cooling devices
    in this system.
    1.3.6.1.4.1.343.2.10.3.4.1.83 tVideo 1 18 This group defines the attributes of video devices in this
    system.
    1.3.6.1.4.1.343.2.10.3.4.1.84 tVideoBios 1 6 This group defines the attributes for the Video BIOS.
    1.3.6.1.4.1.343.2.10.3.4.1.91 tMouse 1 10 This group defines the characteristics of a mouse input device.
    1.3.6.1.4.1.343.2.10.3.4.1.92 tKeyboard 1 7 This group defines the characteristics of the system keyboard.
    1.3.6.1.4.1.343.2.10.3.4.1.100 tEventGenerationForProcessor 1 14 None
    1.3.6.1.4.1.343.2.10.3.4.1.104 tEventGenerationForPowerSupply 1 18 None
    1.3.6.1.4.1.343.2.10.3.4.1.108 tEventGenerationForPhysicalMemory 1 15 None
    1.3.6.1.4.1.343.2.10.3.4.1.113 tEventGenerationForVoltageProbe 1 17 None
    1.3.6.1.4.1.343.2.10.3.4.1.114 tEventGenerationForTemperatureProbe 1 17 None
    1.3.6.1.4.1.343.2.10.3.4.1.116 tEventGenerationForPhysicalContainer 1 11 None
    1.3.6.1.4.1.343.2.10.3.4.1.122 tPointingDevice 1 11 This group defines the characteristics of a pointing device.
    1.3.6.1.4.1.343.2.10.3.4.1.128 tBusGlobalTable 1 3 This global table has one entry for each of the Busesin this
    Component. The unique ID provided to each bus is the index into thi…
    1.3.6.1.4.1.343.2.10.3.4.1.140 tEventGenerationForCoolingDevice 1 8 None
    1.3.6.1.4.1.343.2.10.3.4.1.201 tEventGenerationForPowerUnit 1 10 None
    1.3.6.1.4.1.343.2.10.3.4.1.202 tEventGenerationForCoolingSensors 1 12 None
    1.3.6.1.4.1.343.2.10.3.4.1.205 tEventGenerationForSystemSlots 1 10 None
    1.3.6.1.4.1.343.2.10.3.4.1.1001 tMiftomib 1 4 This group defines attributes required for DMI to
    SNMP translati
    n.
    1.3.6.1.4.1.343.2.10.3.4.1.1004 tSystemControl 1 23 Status and control of global system control features.
    1.3.6.1.4.1.343.2.10.3.4.1.1005 tCoolingSensors 1 20 This table contains one row for each cooling fan
    in the
    system. Each row contains the status and
    control information for a single…
    1.3.6.1.4.1.343.2.10.3.4.1.1006 tSystemEventLog 1 6 This group provides raw access to System Event Log (SEL)
    recordsThis data is intended for use by a Service & Support person
    1.3.6.1.4.1.343.2.10.3.4.1.1008 tPciHotplugDevice 1 6 This group defines the attributes for device occupying PHP
    slots.
    1.3.6.1.4.1.343.2.10.3.4.1.1010 tPagingConfig 1 7 This group defines all Paging configuration parameters which
    areset and read from firmware
    1.3.6.1.4.1.343.2.10.3.4.1.1011 tLocalPagingConfig 1 6 This group defines all Paging configuration parameters which
    areset and read from dmi itself. This group is not instrumented.
    1.3.6.1.4.1.343.2.10.3.4.1.1012 tEmailConfig 1 7 This group defines all Email configuration parameters which
    are set and read from sldb.dmi
    1.3.6.1.4.1.343.2.10.3.4.1.9000 tDpcDiscovery 1 5 This Group contains informationrelated to DPC Server Discovery
    and Service Partition Control