String that identifies the physically labeled socket or
board position where the memory device is located
Parsed from file INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB.mib
Module: INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB
Vendor: Intel Corporation
Module: INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB
[Automatically extracted from oidview.com]
bladeMemLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "String that identifies the physically labeled socket or board position where the memory device is located" ::= { bladeMemoryEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.1 | bladeMemTotalWidth | 0 | 0 | The total width, in bits, of this memory device, including any check or error-correction bits. If there are no error-correction … |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.2 | bladeMemDataWidth | 0 | 0 | The data width, in bits, of this memory device. If 0 and bladeMemTotalWidth is 8 indicates that the device is being used solely … |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.3 | bladeMemSize | 0 | 0 | The size of the memory device. If the value is 0, no memory device is installed in the socket (shouldn't occur as the table is s… |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.4 | bladeMemGranularity | 0 | 0 | The granularity of the bladeMemSize |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.5 | bladeMemFormFactor | 0 | 0 | The implementation form factor for this memory device. |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.6 | bladeMemDeviceSet | 0 | 0 | Identifies when the Memory Device is one of a set of Memory Devices that must be populated with all devices of the same type and … |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.8 | bladeMemBank | 0 | 0 | String that identifies the physically labeled bank where where the memory device is located |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.9 | bladeMemType | 0 | 0 | The type of memory used in this device |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.10 | bladeMemTypeDetail | 0 | 0 | The type of memory used in this device |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.11 | bladeMemSpeed | 0 | 0 | Identifies the speed of the device in megahertz (MHz). |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.12 | bladeMemManufacturer | 0 | 0 | Manufacturer of this memory device |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.13 | bladeMemSerialNo | 0 | 0 | Serial Number of this memory device |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.14 | bladeMemAssetTag | 0 | 0 | Asset Tag of this memory device |
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.15 | bladeMemPart | 0 | 0 | Part Number of this memory device |