This attribute contains the highest reading supported
on
this fan's sensor, measured in the units specified
by the Fan Units attribute.
This attribute may not
apply to all fan types.
Parsed from file Basebrd2.mib.txt
Company: intel
Module: INTELCORPORATIONBASEBOARD-MIB
Vendor: Intel
Module: INTELCORPORATIONBASEBOARD-MIB (basebrd.mib)
Type: TABULAR
Access: read-only
Syntax: DmiInteger
Automatically extracted from www.mibdepot.com
a1005MaximumReading OBJECT-TYPE SYNTAX DmiInteger ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the highest reading supported on this fan's sensor, measured in the units specified by the Fan Units attribute. This attribute may not apply to all fan types." ::= {eCoolingSensors 9}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.343.2.6.2.1.1.16.1.1 | a16Selfid, a1005Selfid | 0 | 0 | A unique number that identifies this row. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.2 | a16ComponentInformation, a1005FruGroupIndex | 0 | 0 | This string attribute encodes the group, attribute, and attribute value required to identify a row in the Component Information tab… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.3 | a16ErrorControl, a1005OperationalGroupIndex | 0 | 0 | This string attribute encodes the group, attribute, and attribute value required to identify a row in the Error Control table. The … |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.4 | a16LogControl | 0 | 0 | This string attribute encodes the group, attribute, and attribute value required to identify a row in the Log Control table. The ro… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.5 | a16OperationalState | 0 | 0 | This string attribute encodes the group, attribute, and attribute value required to identify a row in the Operational State table.… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.6 | a16FanType, a1005CoolingDeviceType | 0 | 0 | This attribute describes the fan type. It has one of the following values: Muffin, Axial, Piezo, or Squirrel Cage. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.7 | a16CfmRating, a1005CfmRating | 0 | 0 | This attribute presents the maximum CFM rating of this fan. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.8 | a16FanUnits, a1005FanUnits | 0 | 0 | This attribute describes the units of fan status measurement. It has one of the following values: RPM, CFM, or OK/Fatal. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.10 | a16MinimumReading, a1005MinimumReading | 0 | 0 | This attribute contains the lowest reading supported on this fan's sensor, measured in the units specified Fan Units attribute. Thi… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.11 | a16CurrentReading, a1005CurrentReading | 0 | 0 | This attribute contains the current fan sensor reading, measured in the units specified by the Fan Units attribute. This attribut… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.12 | a16CurrentStatus | 0 | 0 | This attribute contains the current error status for the fan. It has one of two values: OK or Fatal. The value reflects the curre… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.13 | a16SensorAccuracy, a1005SensorAccuracy | 0 | 0 | This attribute describes the sensor's accuracy in +/- hundredth of a percent. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.14 | a16SensorTolerancePlus, a1005SensorTolerancePlus | 0 | 0 | This attribute describes the sensor's '+' tolerance in the units specified by the Fan Units attribute. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.15 | a16SensorToleranceMinus, a1005SensorToleranceMinus | 0 | 0 | This attribute describes the sensor's '-' tolerance in the units specified by the Fan Units attribute. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.16 | a16WarningThreshold, a1005Non-criticalThreshold | 0 | 0 | This attribute contains the warning threshold level for the fan. The threshold is given in the units specified by the Fan Units at… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.17 | a16MajorThreshold, a1005CriticalThreshold | 0 | 0 | This attribute contains the major error threshold level for the fan. The threshold is given in the units specified by the Fan Uni… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.18 | a16FatalThreshold, a1005Non-recoverableThreshold | 0 | 0 | This attribute contains the fatal error threshold level for the fan. The threshold is given in the units specified by the Fan Uni… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.19 | a16ShortName, a1005CoolingSensorDescription | 0 | 0 | Additional descriptive information about the Cooling sensor orsensor's location. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.20 | a16DomainIdentifier | 0 | 0 | The Domain Identifier attribute identifies rows in the table that are grouped together. For example, all devices in the main cabi… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.21 | a16NominalReading, a1005NominalReading | 0 | 0 | Nominal reading for this fan, in units. 80000000h indicates that this attribute is not supported. |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.22 | a16LowestNormalReading, a1005LowestNormalReading | 0 | 0 | Specified lowest normal reading for this fan, in units. Readings beyond this value indicate an abnormal condition. 80000000h indica… |
1.3.6.1.4.1.343.2.6.2.1.1.16.1.23 | a16HighestNormalReading, a1005HighestNormalReading | 0 | 0 | Specified lowest normal reading for this fan, in units. Readings beyond this value indicate an abnormal condition. 80000000h indica… |