basisShelf OBJECT IDENTIFIER ::= { basisSystem 1 }
basisShelf OBJECT IDENTIFIER ::= { basisSystem 1 }
Vendor: Stratacom
Module: BASIS-MIB
[Automatically extracted from oidview.com]
basisShelf OBJECT IDENTIFIER ::= { basisSystem 1 }
basisShelf OBJECT IDENTIFIER ::= { basisSystem 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.351.110.1.1.1 | shelfTable | 1 | 7 | shelftable |
1.3.6.1.4.1.351.110.1.1.2 | shelfNumOfValidEntries | 1 | 1 | Number of rows in shelfTable. In some MGX series, it is equal to the number of slots in the shelf. |
1.3.6.1.4.1.351.110.1.1.3 | shelfNodeName | 1 | 1 | Has the node name of BASIS for MGX8220 only. For others NodeName supplied by PAR will be returned, A set on this MIB is not allow… |
1.3.6.1.4.1.351.110.1.1.4 | shelfDate | 1 | 1 | This object sets/gets the DATE. The syntax is mm/dd/yyyy |
1.3.6.1.4.1.351.110.1.1.5 | shelfTime | 1 | 1 | shelftime |
1.3.6.1.4.1.351.110.1.1.6 | shelfTmZn | 1 | 1 | shelftmZn |
1.3.6.1.4.1.351.110.1.1.7 | shelfTmZnGMTOff | 1 | 1 | shelftmZnGMTOff |
1.3.6.1.4.1.351.110.1.1.8 | shelfBkPlnType | 1 | 1 | This object contains the back plane type. The possible values are : 1 - For 336Mbps backplane 2 - For 1.2Gbps backplane 3 - For 45G… |
1.3.6.1.4.1.351.110.1.1.9 | shelfBkplnSerialNum | 1 | 1 | A unique value for each shelf, entered in nvram by manf. The serial No. is on the non-volatile RAM on the backplane. |
1.3.6.1.4.1.351.110.1.1.10 | statsMasterIpAddress | 1 | 1 | IP address of the Stats Master. |
1.3.6.1.4.1.351.110.1.1.11 | statsCollectionInterval | 1 | 1 | Statistics collection interval (in minutes). |
1.3.6.1.4.1.351.110.1.1.12 | statsBucketInterval | 1 | 1 | Statistics bucket interval (in minutes). |
1.3.6.1.4.1.351.110.1.1.13 | userName | 1 | 1 | username of the person logging in or logging out. used only in traps currently only limit to 12 chars |
1.3.6.1.4.1.351.110.1.1.14 | shelfIntegratedAlarm | 1 | 1 | Alarm status of the shelf.An implementation may not support all the values. possible values are : clear (1) : shelf is not in al… |
1.3.6.1.4.1.351.110.1.1.15 | shelfAlarmCardBitMap | 1 | 1 | default value is 0, none of the cards is in alarm bit position represents the card physical slot number which is in alarm |
1.3.6.1.4.1.351.110.1.1.16 | axisFeederTkNo | 1 | 1 | ASC creates its cell/frame file based on the feeder trunk number. |
1.3.6.1.4.1.351.110.1.1.17 | axisSvcBillingColInterval | 1 | 1 | SVC billing collection interval (in 0, 15, 30 minute steps). |
1.3.6.1.4.1.351.110.1.1.18 | axisSvcBillingBucketInterval | 1 | 1 | SVC billing bucket interval (in 0, 5, 15, 30 minute steps). |
1.3.6.1.4.1.351.110.1.1.19 | apsIpAddress | 1 | 1 | the IP address of the APS |
1.3.6.1.4.1.351.110.1.1.20 | redundantApsIpAddress | 1 | 1 | the IP address of the redundant APS |
1.3.6.1.4.1.351.110.1.1.21 | axisSvcBilling | 1 | 1 | SVC billing feature. |
1.3.6.1.4.1.351.110.1.1.22 | shelfCBClkRateTable | 1 | 3 | The table has the Clock Rates of each Cell Bus |
1.3.6.1.4.1.351.110.1.1.23 | shelfPowerSupplyVoltage | 1 | 1 | Power Supply voltage rating for some selected MGX Series. two-twenty (1): 220Volts AC. one-ten (2): 110Volts AC. |
1.3.6.1.4.1.351.110.1.1.24 | shelfFilteredAlarm | 0 | 0 | Alarm status of the shelf that allows only a filtered subset of the shelf alarms to be considered in the alarm status. An implem… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.351.110.1.2 | basisAsm | 3 | 15 | None |
1.3.6.1.4.1.351.110.1.3 | axisRedundancy | 1 | 13 | None |
1.3.6.1.4.1.351.110.1.4 | axisSvc | 1 | 14 | None |