Refers to the virtual connection index
Note that the actual range of the index
supported by a card depends on the type of card.
eg: FRSM-4T1/E1 supports a range from 16..271 (256 entries)
FRSM-8T1/E1 supports a range from 16..1015 (1000 entries)
FRSM-T3/E3/HS2 supports a range from 16..2015 (2000 entries)
FRSM-2CT3 supports a range from 16..4015 (4000 entries)
For FRSM12 Card:
Byte 3 = Chassis Number, Byte 2 = Slot Number,
Byte 1 & 0 = channel Number.
Lower two bytes range from 16..16015 (16000 entries)
Parsed from file CISCO-WAN-AXIPOP-MIB.mib
Module: CISCO-WAN-AXIPOP-MIB
The value of this object refers to
frame relay connection.
The value must be same as the value of
the object 'chanNum' in frChanCnfGrpTable.
The value of this object refers to
frame relay connection.
The value must be same as the value of
the object 'chanNum' in frChanCnfGrpTable.
Parsed from file CISCO-WAN-FR-CONN-MIB.my.txt
Company: None
Module: CISCO-WAN-FR-CONN-MIB
The value of this object refers to
frame relay connection.
The value must be same as the value of
the object 'chanNum' in frChanCnfGrpTable.
stateChanNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Refers to the virtual connection index Note that the actual range of the index supported by a card depends on the type of card. eg: FRSM-4T1/E1 supports a range from 16..271 (256 entries) FRSM-8T1/E1 supports a range from 16..1015 (1000 entries) FRSM-T3/E3/HS2 supports a range from 16..2015 (2000 entries) FRSM-2CT3 supports a range from 16..4015 (4000 entries) For FRSM12 Card: Byte 3 = Chassis Number, Byte 2 = Slot Number, Byte 1 & 0 = channel Number. Lower two bytes range from 16..16015 (16000 entries) " ::= { frChanStateGrpEntry 1}
stateChanNum OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object refers to frame relay connection. The value must be same as the value of the object 'chanNum' in frChanCnfGrpTable." ::= { frChanStateGrpEntry 1 }
Vendor: Stratacom
Module: CISCO-WAN-AXIPOP-MIB
[Automatically extracted from oidview.com]
stateChanNum OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object refers to frame relay connection. The value must be same as the value of the object 'chanNum' in frChanCnfGrpTable." ::= { frChanStateGrpEntry 1}
stateChanNum OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object refers to frame relay connection. The value must be same as the value of the object 'chanNum' in frChanCnfGrpTable." ::= { frChanStateGrpEntry 1}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.351.110.5.1.2.2.1.1.2 | chanState | 0 | 0 | This variable indicates the LMI state of the VC (channel) failed(4) is added to distinguish between alarm (when the connection in … |
1.3.6.1.4.1.351.110.5.1.2.2.1.1.3 | xmtAbitState | 0 | 0 | The A bit transmit state 1 - LMI off 2 - LMI on and connection is O.K. 3 - LMI on and connection has failed |
1.3.6.1.4.1.351.110.5.1.2.2.1.1.4 | rcvAbitState | 0 | 0 | The A bit receive state 1 - LMI off 2 - LMI on and connection is O.K. 3 - LMI on and connection has failed |
1.3.6.1.4.1.351.110.5.1.2.2.1.1.5 | xmtATMState | 0 | 0 | This variable indicates the transmit state of the VC (channel) on the ATM side 1 - Not sending any state 2 - Sending AIS OAM state… |
1.3.6.1.4.1.351.110.5.1.2.2.1.1.6 | rcvATMState | 0 | 0 | This variable indicates the receiving state of the VC (channel) on the ATM side 1 - Not receiving any state 2 - Receiving AIS OAM 3… |
1.3.6.1.4.1.351.110.5.1.2.2.1.1.7 | chanStatusBitMap | 0 | 0 | This variable indicates the consolidated bit map of the channel alarm state. Individual bit positions are as defined below. Bit po… |